Impact of age, sex, and cardiac size on the diagnostic performance of myocardial perfusion single-photon emission computed tomography: insights from the REFINE SPECT registry. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Impact of age, sex, and cardiac size on the diagnostic performance of myocardial perfusion single-photon emission computed tomography: insights from the REFINE SPECT registry. (14th October 2021)
- Main Title:
- Impact of age, sex, and cardiac size on the diagnostic performance of myocardial perfusion single-photon emission computed tomography: insights from the REFINE SPECT registry
- Authors:
- Randazzo, M J
Elias, P
Poterucha, T J
Sharir, T
Fish, M B
Ruddy, T D
Kaufmann, P A
Sinusas, A J
Miller, E J
Bateman, T
Dorbala, S
Di Carli, M
Berman, D S
Slomka, P J
Einstein, A J - Abstract:
- Abstract: Background: Single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) is a well-validated non-invasive method for detecting coronary artery disease (CAD). Variations in diagnostic performance due to age and sex have been thoroughly investigated in the literature yet have demonstrated conflicting results. Several studies have associated female sex with reduced accuracy, although others have discovered no significant difference (1). Similarly, while SPECT MPI in the elderly has shown prognostic utility, cardiac event rates are elevated compared to younger patients despite a normal study (2). Additional analyses have suggested that cardiac chamber size may contribute to these observed differences due to its relationship with spatial resolution; however, the interaction of age, sex, and cardiac size remains unknown. Purpose: We aimed to leverage a large, multicenter, international registry to assess the impact of age, sex, and left ventricular size on the diagnostic accuracy of contemporary SPECT MPI. Methods: In 9 centers, 2067 patients (67% male, 64.7±11.2 years) in the REFINE SPECT database (REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT) underwent MPI with new generation solid-state scanners followed by invasive coronary angiography within 6 months (3). Stress total perfusion deficit was quantified automatically, and obstructive CAD was defined as >70% stenosis or >50% for left main. Receiver-operatingAbstract: Background: Single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) is a well-validated non-invasive method for detecting coronary artery disease (CAD). Variations in diagnostic performance due to age and sex have been thoroughly investigated in the literature yet have demonstrated conflicting results. Several studies have associated female sex with reduced accuracy, although others have discovered no significant difference (1). Similarly, while SPECT MPI in the elderly has shown prognostic utility, cardiac event rates are elevated compared to younger patients despite a normal study (2). Additional analyses have suggested that cardiac chamber size may contribute to these observed differences due to its relationship with spatial resolution; however, the interaction of age, sex, and cardiac size remains unknown. Purpose: We aimed to leverage a large, multicenter, international registry to assess the impact of age, sex, and left ventricular size on the diagnostic accuracy of contemporary SPECT MPI. Methods: In 9 centers, 2067 patients (67% male, 64.7±11.2 years) in the REFINE SPECT database (REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT) underwent MPI with new generation solid-state scanners followed by invasive coronary angiography within 6 months (3). Stress total perfusion deficit was quantified automatically, and obstructive CAD was defined as >70% stenosis or >50% for left main. Receiver-operating characteristic curves and corresponding areas under the curve (AUC) were computed to compare diagnostic performance between cohorts created based on age (<75 vs. ≥75 years), sex, and end-diastolic volume (EDV; ≥20th vs. <20th sex-specific percentile). Results: Female and elderly patients had a significantly lower EDV than male and younger patients respectively (p<0.001, Figure 1). Diagnostic accuracy of SPECT was similar by sex (p=0.63). Elderly patients (AUC 0.72 vs. 0.78, p=0.025) and patients with reduced volumes (AUC 0.72 vs. 0.79, p=0.009) exhibited significantly worse performance. When isolating male patients with reduced volumes, a significant difference in accuracy was observed (AUC 0.69 vs. 0.79, p=0.001; Figure 2A), while female patients trended towards significance (p=0.32). Likewise, SPECT performed poorly for elderly patients with reduced volumes (AUC 0.64 vs. 0.78, p=0.01; Figure 2B). If patients possessed any two characteristics of male sex, age ≥75, or low EDV, prediction of CAD with SPECT was significantly decreased (p=0.002; Figure 2C). Conclusions: Our findings suggest that men with reduced cardiac volumes display worse diagnostic SPECT performance, although it is uncertain whether a pathophysiologic reason exists or further investigation is required for female patients. Patients age ≥75 tended to have lower cardiac volumes as well as lower diagnostic performance. Given these results, alternative diagnostic modalities may better diagnose CAD in patients with these characteristics. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Single Photon Emission Computed Tomography (SPECT)
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0254 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25015.xml