Automated non-invasive pressure-volume loop analysis of cardiac aging in a large cohort of healthy community dwellers. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Automated non-invasive pressure-volume loop analysis of cardiac aging in a large cohort of healthy community dwellers. (14th October 2021)
- Main Title:
- Automated non-invasive pressure-volume loop analysis of cardiac aging in a large cohort of healthy community dwellers
- Authors:
- Ruijsink, J B
Puyol-Anton, E
Mariscal Harana, J
Juarez-Orozco, L E
King, A P
Razavi, R - Abstract:
- Abstract: Background/Introduction: Pressure-volume loops (PVloops) provide a wealth of information on cardiac function that is not readily available from cardiac imaging alone. Methods: To estimate left ventricular (LV) PVloops non-invasively have been available, but have so far not been used to interrogate ventricular function in large patient cohorts, due to the complexity of estimating PVloops. A new method was recently validated that construct PVloops non-invasively from cine cardiac magnetic resonance (CMR), based on the time-varying elastance model [1]. At the same time, we have validated a framework for automated, quality controlled analysis of cine CMR in large cohorts of patients/subjects [2]. Combining these two methods could automated PVloop estimation, enabling analysis of ventricular pressure-volume relationships in large study populations. Purpose: Evaluate if CMR-based non-invasive PVloops can be used to interrogate the impact of cardiac ageing on LV function occurring in a large population of healthy community dwellers. Methods: Non-invasive PVloops were calculated from a full cardiac cycle LV volume curve and brachial blood pressure data using a recently validated method based on the time-varying elastance model [1], in 7, 650 healthy community dwellers from the UKBiobank population study. The LV volume curve was automatically obtained using our state-of-the-art, quality controlled deep learning (DL) based cine CMR analysis framework [2]. External Work,Abstract: Background/Introduction: Pressure-volume loops (PVloops) provide a wealth of information on cardiac function that is not readily available from cardiac imaging alone. Methods: To estimate left ventricular (LV) PVloops non-invasively have been available, but have so far not been used to interrogate ventricular function in large patient cohorts, due to the complexity of estimating PVloops. A new method was recently validated that construct PVloops non-invasively from cine cardiac magnetic resonance (CMR), based on the time-varying elastance model [1]. At the same time, we have validated a framework for automated, quality controlled analysis of cine CMR in large cohorts of patients/subjects [2]. Combining these two methods could automated PVloop estimation, enabling analysis of ventricular pressure-volume relationships in large study populations. Purpose: Evaluate if CMR-based non-invasive PVloops can be used to interrogate the impact of cardiac ageing on LV function occurring in a large population of healthy community dwellers. Methods: Non-invasive PVloops were calculated from a full cardiac cycle LV volume curve and brachial blood pressure data using a recently validated method based on the time-varying elastance model [1], in 7, 650 healthy community dwellers from the UKBiobank population study. The LV volume curve was automatically obtained using our state-of-the-art, quality controlled deep learning (DL) based cine CMR analysis framework [2]. External Work, pressure-volume-area (PVA), end-systolic pressure (Pes), ventricular elastance (Ees, an estimate of contractility) and arterial elastance (Ea) and energy per ejected volume (EEV: PVA/ stroke volume) were calculated from the PVloops. We performed univariate regression between PVloop parameters and age. We also calculated the additional impact of cardiovascular risk-factors in a multivariate analysis. Results: See results in table 1. With age, LV volumes fall (p<0.001) in healthy subjects, while systolic blood pressure and Pes increases (both p<0.001). As a result of the higher afterload, PVA (p=0.894) and EW (p=0.499) do not significantly change with age despite a lower SV. Arterial elastance (Ea) increased, and so did contractility, as measured by Ees (p<0.001). Due to all these changes, EEV increased with age (p<0.001). In multivariate analysis, cardiovascular risk factors hypercholesterolemia and hypertension negatively impacted Pes, PVA, Ees and EEV. Diabetes and smoking habits did not. Conclusion: Non-invasive CMR-based PVloop analyses capture the impact of known changes occurring during cardiac ageing on cardiac work, contractility and energetic expenditure. Obtaining PVloops automatically using our AI analysis system in this large cohort of healthy subjects allows to formulate reference for assessment of cardiac disease. Funding Acknowledgement: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): The authors acknowledge financial support (support) the National Institute for Health Research (NIHR) Cardiovascular MedTech Co-operative (previously existing as the Cardiovascular Healthcare Technology Co-operative 2012 - 2017) award to the Guy's and St Thomas' NHS Foundation Trust, in partnership with King's College London and the NIHR comprehensive Biomedical Research Centre of the Guy's & St Thomas' NHS Foundation Trust. The views expressed are those of the author(s) and not necessarily those of the NHS, the NIHR or the Department of Health … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Systolic and Diastolic Function
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0107 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25015.xml