Lung heterogeneity and deadspace volume in animals with acute respiratory distress syndrome using the inspired sinewave test. (9th December 2020)
- Record Type:
- Journal Article
- Title:
- Lung heterogeneity and deadspace volume in animals with acute respiratory distress syndrome using the inspired sinewave test. (9th December 2020)
- Main Title:
- Lung heterogeneity and deadspace volume in animals with acute respiratory distress syndrome using the inspired sinewave test
- Authors:
- Tran, Minh C
Crockett, Douglas C
Formenti, Federico
Phan, Phi A
Hedenstierna, Göran
Larsson, Anders
Payne, Stephen J
Farmery, Andrew D - Abstract:
- Abstract: Acute respiratory distress syndrome (ARDS) is associated with a high rate of morbidity and mortality, as patients undergoing mechanical ventilation are at risk of ventilator-induced lung injuries. Objective : To measure the lung heterogeneity and deadspace volume to find safer ventilator strategies. The ventilator settings could then offer homogeneous ventilation and theoretically equalize and reduce tidal strain/stress in the lung parenchyma. Approach : The inspired sinewave test (IST) is a non-invasive lung measurement tool which does not require cooperation from the patient. The IST can measure the effective lung volume, pulmonary blood flow and deadspace volume. We developed a computational simulation of the cardiopulmonary system to allow lung heterogeneity to be quantified using data solely derived from the IST. Then, the method to quantify lung heterogeneity using two IST tracer gas frequencies (180 and 60 s) was introduced and used in lung simulations and animal models. Thirteen anaesthetized pigs were studied with the IST both before and after experimental lung injury (saline-lavage ARDS model). The deadspace volume was compared between the IST and the SF6 washout method. Main results : The IST could measure lung heterogeneity using two tracer gas frequencies. Furthermore, the value of IST ventilation heterogeneity in ARDS lungs was higher than in control lungs at a positive end-expiratory pressure of 10 cmH2 O (area under the curve = 0.85, p < 0.001 ).Abstract: Acute respiratory distress syndrome (ARDS) is associated with a high rate of morbidity and mortality, as patients undergoing mechanical ventilation are at risk of ventilator-induced lung injuries. Objective : To measure the lung heterogeneity and deadspace volume to find safer ventilator strategies. The ventilator settings could then offer homogeneous ventilation and theoretically equalize and reduce tidal strain/stress in the lung parenchyma. Approach : The inspired sinewave test (IST) is a non-invasive lung measurement tool which does not require cooperation from the patient. The IST can measure the effective lung volume, pulmonary blood flow and deadspace volume. We developed a computational simulation of the cardiopulmonary system to allow lung heterogeneity to be quantified using data solely derived from the IST. Then, the method to quantify lung heterogeneity using two IST tracer gas frequencies (180 and 60 s) was introduced and used in lung simulations and animal models. Thirteen anaesthetized pigs were studied with the IST both before and after experimental lung injury (saline-lavage ARDS model). The deadspace volume was compared between the IST and the SF6 washout method. Main results : The IST could measure lung heterogeneity using two tracer gas frequencies. Furthermore, the value of IST ventilation heterogeneity in ARDS lungs was higher than in control lungs at a positive end-expiratory pressure of 10 cmH2 O (area under the curve = 0.85, p < 0.001 ). Values for the deadspace volume measured by the IST have a strong relationship with the measured values of SF6 (9 ml bias and limits of agreement from −79 to 57 ml in control animals). Significance : The IST technique has the potential for use in the identification of ventilation and perfusion heterogeneity during ventilator support. … (more)
- Is Part Of:
- Physiological measurement. Volume 41:Number 11(2020)
- Journal:
- Physiological measurement
- Issue:
- Volume 41:Number 11(2020)
- Issue Display:
- Volume 41, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 11
- Issue Sort Value:
- 2020-0041-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12-09
- Subjects:
- acute respiratory distress syndrome -- ARDS -- IST -- lung simulation -- lung heterogeneity
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/1361-6579/abc0b5 ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25001.xml