Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization. (17th June 2014)
- Record Type:
- Journal Article
- Title:
- Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization. (17th June 2014)
- Main Title:
- Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization
- Authors:
- Layritz, Christian
Schmid, Jasmin
Achenbach, Stephan
Ulzheimer, Stefan
Wuest, Wolfgang
May, Matthias
Ropers, Dieter
Klinghammer, Lutz
Daniel, Werner G.
Pflederer, Tobias
Lell, Michael - Abstract:
- Abstract: Objective: To evaluate the image quality and diagnostic accuracy of very low-dose computed tomography (CT) angiography (CTA) for the evaluation of coronary artery stenosis. Background: Iterative reconstruction (IR) has shown to substantially reduce image noise and hence permit the use of very low-dose data acquisition protocols in coronary CTA. Methods: Fifty symptomatic patients with an intermediate likelihood for coronary artery disease underwent coronary CTA (heart rate: 59 ± 5 bpm, prospectively ECG-triggered axial acquisition, 100 kV, 160 mAs, 2 × 128 × 0.6 mm collimation, 60 mL contrast, 6 mL/s) prior to invasive coronary angiography. CTA images were reconstructed using both standard filtered back projection (FBP) and a raw data-based IR algorithm [Sinogram Affirmed Iterative Reconstruction (SAFIRE), Siemens Healthcare]. Subjective image quality (four-point Likert scale from 0 = non-diagnostic to 3 = excellent image quality), image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), as well as the presence of coronary stenosis >50% were independently determined by two observers. Results: The mean dose–length product was 46.8 ± 3.5 mGy cm (estimated effective dose 0.66 ± 0.05 mSv). IR led to significantly improved objective image quality compared with FBP (image noise: 41 ± 12 vs. 49 ± 11 HU, P < 0.0001; CNR: 16 ± 8 vs. 12 ± 4, P < 0.0001; SNR: 13 ± 7 vs. 10 ± 3, P < 0.0001). Four coronary segments were not evaluable on FBP data, whereas allAbstract: Objective: To evaluate the image quality and diagnostic accuracy of very low-dose computed tomography (CT) angiography (CTA) for the evaluation of coronary artery stenosis. Background: Iterative reconstruction (IR) has shown to substantially reduce image noise and hence permit the use of very low-dose data acquisition protocols in coronary CTA. Methods: Fifty symptomatic patients with an intermediate likelihood for coronary artery disease underwent coronary CTA (heart rate: 59 ± 5 bpm, prospectively ECG-triggered axial acquisition, 100 kV, 160 mAs, 2 × 128 × 0.6 mm collimation, 60 mL contrast, 6 mL/s) prior to invasive coronary angiography. CTA images were reconstructed using both standard filtered back projection (FBP) and a raw data-based IR algorithm [Sinogram Affirmed Iterative Reconstruction (SAFIRE), Siemens Healthcare]. Subjective image quality (four-point Likert scale from 0 = non-diagnostic to 3 = excellent image quality), image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), as well as the presence of coronary stenosis >50% were independently determined by two observers. Results: The mean dose–length product was 46.8 ± 3.5 mGy cm (estimated effective dose 0.66 ± 0.05 mSv). IR led to significantly improved objective image quality compared with FBP (image noise: 41 ± 12 vs. 49 ± 11 HU, P < 0.0001; CNR: 16 ± 8 vs. 12 ± 4, P < 0.0001; SNR: 13 ± 7 vs. 10 ± 3, P < 0.0001). Four coronary segments were not evaluable on FBP data, whereas all segments showed diagnostic image quality with IR. To detect significant coronary stenosis, sensitivity, specificity, positive predictive value, and negative predictive value were 69% (11/16), 97% (175/180), 69% (11/16), and 97% (175/180) per vessel with FBP data sets, respectively. With IR data sets, the corresponding values were 81% (13/16), 97% (178/184), 68% (13/19), and 98% (178/181). These differences were not statistically significant ( P = 0.617). Conclusions: Raw data-based IR significantly improves image quality in very low-dose prospectively ECG-triggered coronary dual-source CTA when compared with standard reconstruction using FBP. … (more)
- Is Part Of:
- European heart journal. Volume 15:Number 11(2014:Nov.)
- Journal:
- European heart journal
- Issue:
- Volume 15:Number 11(2014:Nov.)
- Issue Display:
- Volume 15, Issue 11 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 11
- Issue Sort Value:
- 2014-0015-0011-0000
- Page Start:
- 1238
- Page End:
- 1245
- Publication Date:
- 2014-06-17
- Subjects:
- Coronary CT angiography -- Low dose -- Iterative reconstruction
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeu113 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24970.xml