What determines accuracy of chemical identification when using microspectroscopy for the analysis of microplastics?. (February 2023)
- Record Type:
- Journal Article
- Title:
- What determines accuracy of chemical identification when using microspectroscopy for the analysis of microplastics?. (February 2023)
- Main Title:
- What determines accuracy of chemical identification when using microspectroscopy for the analysis of microplastics?
- Authors:
- De Frond, Hannah
Cowger, Win
Renick, Violet
Brander, Susanne
Primpke, Sebastian
Sukumaran, Suja
Elkhatib, Dounia
Barnett, Steve
Navas-Moreno, Maria
Rickabaugh, Keith
Vollnhals, Florian
O'Donnell, Bridget
Lusher, Amy
Lee, Eunah
Lao, Wenjian
Amarpuri, Gaurav
Sarau, George
Christiansen, Silke - Abstract:
- Abstract: Fourier transform infrared (FTIR) and Raman microspectroscopy are methods applied in microplastics research to determine the chemical identity of microplastics. These techniques enable quantification of microplastic particles across various matrices. Previous work has highlighted the benefits and limitations of each method and found these to be complimentary. Within this work, metadata collected within an interlaboratory method validation study was used to determine which variables most influenced successful chemical identification of un-weathered microplastics in simulated drinking water samples using FTIR and Raman microspectroscopy. No variables tested had a strong correlation with the accuracy of chemical identification (r = ≤0.63). The variables most correlated with accuracy differed between the two methods, and include both physical characteristics of particles (color, morphology, size, polymer type), and instrumental parameters (spectral collection mode, spectral range). Based on these results, we provide technical recommendations to improve capabilities of both methods for measuring microplastics in drinking water and highlight priorities for further research. For FTIR microspectroscopy, recommendations include considering the type of particle in question to inform sample presentation and spectral collection mode for sample analysis. Instrumental parameters should be adjusted for certain particle types when using Raman microspectroscopy. For bothAbstract: Fourier transform infrared (FTIR) and Raman microspectroscopy are methods applied in microplastics research to determine the chemical identity of microplastics. These techniques enable quantification of microplastic particles across various matrices. Previous work has highlighted the benefits and limitations of each method and found these to be complimentary. Within this work, metadata collected within an interlaboratory method validation study was used to determine which variables most influenced successful chemical identification of un-weathered microplastics in simulated drinking water samples using FTIR and Raman microspectroscopy. No variables tested had a strong correlation with the accuracy of chemical identification (r = ≤0.63). The variables most correlated with accuracy differed between the two methods, and include both physical characteristics of particles (color, morphology, size, polymer type), and instrumental parameters (spectral collection mode, spectral range). Based on these results, we provide technical recommendations to improve capabilities of both methods for measuring microplastics in drinking water and highlight priorities for further research. For FTIR microspectroscopy, recommendations include considering the type of particle in question to inform sample presentation and spectral collection mode for sample analysis. Instrumental parameters should be adjusted for certain particle types when using Raman microspectroscopy. For both instruments, the study highlighted the need for harmonization of spectral reference libraries among research groups, including the use of libraries containing reference materials of both weathered plastic and natural materials that are commonly found in environmental samples. Graphical abstract: Image 1 Highlights: Harmonization of methods is a priority in microplastics research. FTIR and Raman microspectroscopy are common methods used to analyze microplastics. Variables for successful identification using microspectroscopy were identified. Particle characteristics and instrumental parameters influence identification success. Technical method recommendations for using FTIR and Raman microspectroscopy are provided. … (more)
- Is Part Of:
- Chemosphere. Volume 313(2023)
- Journal:
- Chemosphere
- Issue:
- Volume 313(2023)
- Issue Display:
- Volume 313, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 313
- Issue:
- 2023
- Issue Sort Value:
- 2023-0313-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-02
- Subjects:
- Pollution -- Periodicals
Pollution -- Physiological effect -- Periodicals
Environmental sciences -- Periodicals
Atmospheric chemistry -- Periodicals
551.511 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00456535/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.chemosphere.2022.137300 ↗
- Languages:
- English
- ISSNs:
- 0045-6535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.280000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24956.xml