Does perfect filtering really guarantee perfect phase correction for diffusion MRI data?. (January 2023)
- Record Type:
- Journal Article
- Title:
- Does perfect filtering really guarantee perfect phase correction for diffusion MRI data?. (January 2023)
- Main Title:
- Does perfect filtering really guarantee perfect phase correction for diffusion MRI data?
- Authors:
- Liu, Feihong
Yang, Junwei
Feng, Mingyue
Cui, Zhiming
He, Xiaowei
Zhou, Luping
Feng, Jun
Shen, Dinggang - Abstract:
- Abstract: Owing to its merit of avoiding noise-floor, phase correction is recently used to reconstruct real-valued diffusion MRI data by employing an image filter to estimate the noise-free background phase. However, several studies report an unexpected signal-loss issue for their reconstruction results, with its causing reason still remaining unclear. Although phase correction has achieved promising results in mitigating the signal-loss issue via improving the employed image filter, we have observed counterintuitive results that an advanced filter generates severe artifacts in our previous work. Considering the potential issues with phase correction procedures, in this paper, we argue that even a perfect image filter is insufficient to produce perfect phase correction. To point out the reason why phase correction introduces signal-loss and address this issue, we first propose a complex polar coordinate system (CPCS) to analyze its procedures in detail; second, based on CPCS, we find that phase correction has not sufficiently utilized the background phase, and thus propose a quantitative criterion to fully exploit the background phase; eventually, we propose a phase calibration procedure to remedy current phase correction. Extensive experimental results, including those on synthetic and real diffusion MRI data, demonstrate that our proposed method significantly reduces signal-loss and also eliminates artifacts in FA maps, particularly with improved accuracy on FA.Abstract: Owing to its merit of avoiding noise-floor, phase correction is recently used to reconstruct real-valued diffusion MRI data by employing an image filter to estimate the noise-free background phase. However, several studies report an unexpected signal-loss issue for their reconstruction results, with its causing reason still remaining unclear. Although phase correction has achieved promising results in mitigating the signal-loss issue via improving the employed image filter, we have observed counterintuitive results that an advanced filter generates severe artifacts in our previous work. Considering the potential issues with phase correction procedures, in this paper, we argue that even a perfect image filter is insufficient to produce perfect phase correction. To point out the reason why phase correction introduces signal-loss and address this issue, we first propose a complex polar coordinate system (CPCS) to analyze its procedures in detail; second, based on CPCS, we find that phase correction has not sufficiently utilized the background phase, and thus propose a quantitative criterion to fully exploit the background phase; eventually, we propose a phase calibration procedure to remedy current phase correction. Extensive experimental results, including those on synthetic and real diffusion MRI data, demonstrate that our proposed method significantly reduces signal-loss and also eliminates artifacts in FA maps, particularly with improved accuracy on FA. Highlights: Point out the reason why current phase correction introduces signal-loss while avoiding noise-floor. Propose a more explicit definition of noise-floor and a quantitative criterion decerning noise-floor. Propose a phase calibration procedure to remedy current phase correction with regard to mitigating signal-loss. … (more)
- Is Part Of:
- Computerized medical imaging and graphics. Volume 103(2023)
- Journal:
- Computerized medical imaging and graphics
- Issue:
- Volume 103(2023)
- Issue Display:
- Volume 103, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 103
- Issue:
- 2023
- Issue Sort Value:
- 2023-0103-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- Phase correction -- Noise-floor -- Spatially-varying noise -- Adaptive filtering
Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnosis, Radioscopic -- Data processing -- Periodicals
Diagnostic Imaging -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Diagnostic imaging
Periodicals
Electronic journals
Electronic journals
616.0754 - Journal URLs:
- http://www.journals.elsevier.com/computerized-medical-imaging-and-graphics/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compmedimag.2022.102160 ↗
- Languages:
- English
- ISSNs:
- 0895-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24945.xml