Scalable and modular 8‐channel transmit and 8‐channel flexible receive coil array for 19F MRI of large animals. Issue 3 (13th October 2022)
- Record Type:
- Journal Article
- Title:
- Scalable and modular 8‐channel transmit and 8‐channel flexible receive coil array for 19F MRI of large animals. Issue 3 (13th October 2022)
- Main Title:
- Scalable and modular 8‐channel transmit and 8‐channel flexible receive coil array for 19F MRI of large animals
- Authors:
- Özen, Ali Caglar
Spreter, Felix
Schimpf, Waldemar
Fischer, Johannes
Ilbey, Serhat
Reiss, Simon
Maier, Alexander
von Elverfeldt, Dominik
Heidt, Timo
von zur Mühlen, Constantin
Bock, Michael - Abstract:
- Abstract : Purpose: To introduce an RF coil system consisting of an 8‐channel transmit (Tx) and 8‐channel receive (Rx) coil arrays for 19 F MRI of large animals. Methods: The Tx efficiency and homogeneity of the 8‐element loop coil array (loop size: 6 × 15 cm 2 ) were simulated for two different pig models rendered from MR images. An 8‐channel Rx coil array consisting of a flexible 6‐channel posterior and a 2‐channel planar anterior array was designed to fit on the abdomen of an average‐sized pig in supine position. Measurements were performed in a grid phantom and ex vivo on a pig model with perfluoroctylbromide (PFOB)–filled tubes inserted in the thorax. Results: Measured and simulated Tx efficiency and homogeneity for the 8‐channel and 5‐channel arrays were in good agreement: 1.87 ± 0.22μT/√kW versus 1.96 ± 0.29μT/√kW, and 2.29 ± 0.39μT/√kW versus 2.41 ± 0.37μT/√kW. An isolation of 38 ± 8 dB is achieved between the 19 F Tx and Rx elements, and over 30 dB between the 1 H and 19 F elements. The PFOB‐filled vials could be clearly identified within the cadaver abdomen with an SNR of 275 ± 51 for a 3D gradient‐echo sequence with 2‐mm isotropic resolution and 12 averages, acquired in 9:52 min:s. Performance of the Tx array was robust against phase and amplitude mismatches at the input ports. Conclusions: A modular and scalable Tx array offers improved Tx efficiency in 19 F MRI of large animals with various sizes. Although conventional birdcage coils have superior Tx efficiencyAbstract : Purpose: To introduce an RF coil system consisting of an 8‐channel transmit (Tx) and 8‐channel receive (Rx) coil arrays for 19 F MRI of large animals. Methods: The Tx efficiency and homogeneity of the 8‐element loop coil array (loop size: 6 × 15 cm 2 ) were simulated for two different pig models rendered from MR images. An 8‐channel Rx coil array consisting of a flexible 6‐channel posterior and a 2‐channel planar anterior array was designed to fit on the abdomen of an average‐sized pig in supine position. Measurements were performed in a grid phantom and ex vivo on a pig model with perfluoroctylbromide (PFOB)–filled tubes inserted in the thorax. Results: Measured and simulated Tx efficiency and homogeneity for the 8‐channel and 5‐channel arrays were in good agreement: 1.87 ± 0.22μT/√kW versus 1.96 ± 0.29μT/√kW, and 2.29 ± 0.39μT/√kW versus 2.41 ± 0.37μT/√kW. An isolation of 38 ± 8 dB is achieved between the 19 F Tx and Rx elements, and over 30 dB between the 1 H and 19 F elements. The PFOB‐filled vials could be clearly identified within the cadaver abdomen with an SNR of 275 ± 51 for a 3D gradient‐echo sequence with 2‐mm isotropic resolution and 12 averages, acquired in 9:52 min:s. Performance of the Tx array was robust against phase and amplitude mismatches at the input ports. Conclusions: A modular and scalable Tx array offers improved Tx efficiency in 19 F MRI of large animals with various sizes. Although conventional birdcage coils have superior Tx efficiency within the target region of interest, scalability of the Tx array to animal size is a major benefit. The described 19 F coil provides homogeneous excitation and high sensitivity detection in large pig models. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 3(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 3(2023)
- Issue Display:
- Volume 89, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 3
- Issue Sort Value:
- 2023-0089-0003-0000
- Page Start:
- 1237
- Page End:
- 1250
- Publication Date:
- 2022-10-13
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29490 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24965.xml