Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis. (29th December 2020)
- Record Type:
- Journal Article
- Title:
- Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis. (29th December 2020)
- Main Title:
- Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis
- Authors:
- Alabousi, Mostafa
Wadera, Akshay
Kashif Al-Ghita, Mohammed
Kashef Al-Ghetaa, Rayeh
Salameh, Jean-Paul
Pozdnyakov, Alex
Zha, Nanxi
Samoilov, Lucy
Dehmoobad Sharifabadi, Anahita
Sadeghirad, Behnam
Freitas, Vivianne
McInnes, Matthew DF
Alabousi, Abdullah - Abstract:
- Abstract: Background: Our objective was to perform a systematic review and meta-analysis comparing the breast cancer detection rate (CDR), invasive CDR, recall rate, and positive predictive value 1 (PPV1) of digital mammography (DM) alone, combined digital breast tomosynthesis (DBT) and DM, combined DBT and synthetic 2-dimensional mammography (S2D), and DBT alone. Methods: MEDLINE and Embase were searched until April 2020 to identify comparative design studies reporting on patients undergoing routine breast cancer screening. Random effects model proportional meta-analyses estimated CDR, invasive CDR, recall rate, and PPV1. Meta-regression modeling was used to compare imaging modalities. All statistical tests were 2-sided. Results: Forty-two studies reporting on 2 606 296 patients (13 003 breast cancer cases) were included. CDR was highest in combined DBT and DM (6.36 per 1000 screened, 95% confidence interval [CI] = 5.62 to 7.14, P < .001), and combined DBT and S2D (7.40 per 1000 screened, 95% CI = 6.49 to 8.37, P < .001) compared with DM alone (4.68 per 1000 screened, 95% CI = 4.28 to 5.11). Invasive CDR was highest in combined DBT and DM (4.53 per 1000 screened, 95% CI = 3.97 to 5.12, P = .003) and combined DBT and S2D (5.68 per 1000 screened, 95% CI = 4.43 to 7.09, P < .001) compared with DM alone (3.42 per 1000 screened, 95% CI = 3.02 to 3.83). Recall rate was lowest in combined DBT and S2D (42.3 per 1000 screened, 95% CI = 37.4 to 60.4, P<.001). PPV1 was highest inAbstract: Background: Our objective was to perform a systematic review and meta-analysis comparing the breast cancer detection rate (CDR), invasive CDR, recall rate, and positive predictive value 1 (PPV1) of digital mammography (DM) alone, combined digital breast tomosynthesis (DBT) and DM, combined DBT and synthetic 2-dimensional mammography (S2D), and DBT alone. Methods: MEDLINE and Embase were searched until April 2020 to identify comparative design studies reporting on patients undergoing routine breast cancer screening. Random effects model proportional meta-analyses estimated CDR, invasive CDR, recall rate, and PPV1. Meta-regression modeling was used to compare imaging modalities. All statistical tests were 2-sided. Results: Forty-two studies reporting on 2 606 296 patients (13 003 breast cancer cases) were included. CDR was highest in combined DBT and DM (6.36 per 1000 screened, 95% confidence interval [CI] = 5.62 to 7.14, P < .001), and combined DBT and S2D (7.40 per 1000 screened, 95% CI = 6.49 to 8.37, P < .001) compared with DM alone (4.68 per 1000 screened, 95% CI = 4.28 to 5.11). Invasive CDR was highest in combined DBT and DM (4.53 per 1000 screened, 95% CI = 3.97 to 5.12, P = .003) and combined DBT and S2D (5.68 per 1000 screened, 95% CI = 4.43 to 7.09, P < .001) compared with DM alone (3.42 per 1000 screened, 95% CI = 3.02 to 3.83). Recall rate was lowest in combined DBT and S2D (42.3 per 1000 screened, 95% CI = 37.4 to 60.4, P<.001). PPV1 was highest in combined DBT and DM (10.0%, 95% CI = 8.0% to 12.0%, P = .004), and combined DBT and S2D (16.0%, 95% CI = 10.0% to 23.0%, P < .001), whereas no difference was detected for DBT alone (7.0%, 95% CI = 6.0% to 8.0%, P = .75) compared with DM alone (7.0%, 95.0% CI = 5.0% to 8.0%). Conclusions: Our findings provide evidence on key performance metrics for DM, DBT alone, combined DBT and DM, and combined DBT and S2D, which may inform optimal application of these modalities for breast cancer screening. … (more)
- Is Part Of:
- Journal of the National Cancer Institute. Volume 113:Number 6(2021)
- Journal:
- Journal of the National Cancer Institute
- Issue:
- Volume 113:Number 6(2021)
- Issue Display:
- Volume 113, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 113
- Issue:
- 6
- Issue Sort Value:
- 2021-0113-0006-0000
- Page Start:
- 680
- Page End:
- 690
- Publication Date:
- 2020-12-29
- Subjects:
- Cancer -- Periodicals
Cancer -- Research -- Periodicals
616.994 - Journal URLs:
- https://jnci.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/jnci/djaa205 ↗
- Languages:
- English
- ISSNs:
- 0027-8874
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4830.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24933.xml