Microthin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty: A Randomized Clinical Trial. Issue 9 (September 2021)
- Record Type:
- Journal Article
- Title:
- Microthin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty: A Randomized Clinical Trial. Issue 9 (September 2021)
- Main Title:
- Microthin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty
- Authors:
- Matsou, Artemis
Pujari, Rathin
Sarwar, Hammad
Rana, Mrinal
Myerscough, James
Thomson, Susan M.
Nandakumar, Girinath
Zhang, Jufen
Rajan, Madhavan S. - Abstract:
- Abstract : Purpose: To compare visual outcomes, complications, and vision-related quality of life (QoL) after microthin Descemet stripping automated endothelial keratoplasty (MT-DSAEK) versus Descemet membrane endothelial keratoplasty (DMEK) for the management of corneal endothelial dysfunction in Fuchs dystrophy. Methods: This is a prospective, double-blinded randomized controlled clinical trial. Patients with visually significant endothelial decompensation from Fuchs dystrophy were prospectively randomized to receive MT-DSAEK or DMEK surgery. The primary outcome was best spectacle-corrected visual acuity (BSCVA) at 12 months. Secondary outcomes included refraction, keratometry, endothelial cell count, complications, and vision-related QoL at 6 and 12 months postoperatively. Results: A total of 56 eyes of 56 patients were enrolled, 28 in each group. Postoperatively, LogMAR mean BSCVA in the MT-DSAEK group was 0.17 ± 0.08 and 0.11 ± 0.09 at 6 and 12 months compared with 0.09 ± 0.13 and 0.04 ± 0.13 after DMEK ( P = 0.03, P = 0.002 respectively) with the DMEK cohort achieving 3.5 logarithm of the minimum angle of resolution letters better BSCVA at 1 year compared with MT-DSAEK. Complication rates were similar with 3.5% rebubbling rate in both groups, 1 primary graft failure in DMEK and a single endothelial rejection in the MT-DSAEK arm. Vision-related QoL was comparable at 6 and 12 months postoperatively, and no eyes demonstrated loss of vision from preoperative BSCVA.Abstract : Purpose: To compare visual outcomes, complications, and vision-related quality of life (QoL) after microthin Descemet stripping automated endothelial keratoplasty (MT-DSAEK) versus Descemet membrane endothelial keratoplasty (DMEK) for the management of corneal endothelial dysfunction in Fuchs dystrophy. Methods: This is a prospective, double-blinded randomized controlled clinical trial. Patients with visually significant endothelial decompensation from Fuchs dystrophy were prospectively randomized to receive MT-DSAEK or DMEK surgery. The primary outcome was best spectacle-corrected visual acuity (BSCVA) at 12 months. Secondary outcomes included refraction, keratometry, endothelial cell count, complications, and vision-related QoL at 6 and 12 months postoperatively. Results: A total of 56 eyes of 56 patients were enrolled, 28 in each group. Postoperatively, LogMAR mean BSCVA in the MT-DSAEK group was 0.17 ± 0.08 and 0.11 ± 0.09 at 6 and 12 months compared with 0.09 ± 0.13 and 0.04 ± 0.13 after DMEK ( P = 0.03, P = 0.002 respectively) with the DMEK cohort achieving 3.5 logarithm of the minimum angle of resolution letters better BSCVA at 1 year compared with MT-DSAEK. Complication rates were similar with 3.5% rebubbling rate in both groups, 1 primary graft failure in DMEK and a single endothelial rejection in the MT-DSAEK arm. Vision-related QoL was comparable at 6 and 12 months postoperatively, and no eyes demonstrated loss of vision from preoperative BSCVA. Conclusions: DMEK surgery resulted in significantly better BSCVA at 1, 3, 6, and 12 months postoperatively compared with MT-DSAEK. Patient satisfaction was similar with no differences reported in vision-related QoL scores, as was the complications profile between groups. Thus, our results favor DMEK as the better choice procedure for eyes with Fuchs-related corneal decompensation without ocular comorbidities. … (more)
- Is Part Of:
- Cornea. Volume 40:Issue 9(2021)
- Journal:
- Cornea
- Issue:
- Volume 40:Issue 9(2021)
- Issue Display:
- Volume 40, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 40
- Issue:
- 9
- Issue Sort Value:
- 2021-0040-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09
- Subjects:
- DMEK -- thin DSAEK -- ultrathin DSAEK -- microthin DSAEK -- endothelial keratoplasty
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002601 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24949.xml