Cerebrovascular Events in Patients With Centrifugal-Flow Left Ventricular Assist Devices: Propensity Score–Matched Analysis From the Intermacs Registry. Issue 10 (7th September 2021)
- Record Type:
- Journal Article
- Title:
- Cerebrovascular Events in Patients With Centrifugal-Flow Left Ventricular Assist Devices: Propensity Score–Matched Analysis From the Intermacs Registry. Issue 10 (7th September 2021)
- Main Title:
- Cerebrovascular Events in Patients With Centrifugal-Flow Left Ventricular Assist Devices
- Authors:
- Cho, Sung-Min
Mehaffey, J. Hunter
Meyers, Susan L.
Cantor, Ryan S.
Starling, Randall C.
Kirklin, James K.
Jacobs, Jeffrey P.
Kern, John
Uchino, Ken
Yarboro, Leora T. - Abstract:
- Abstract : Background: Ischemic and hemorrhagic cerebrovascular accidents remain common among patients with centrifugal-flow left ventricular assist devices, despite improvements in survival and device longevity. We compared the incidence of neurologic adverse events (NAEs) associated with 2 contemporary centrifugal-flow left ventricular assist devices: the Abbott HeartMate3 (HM3) and the Medtronic HeartWare HVAD (HVAD). Methods: Using the Society of Thoracic Surgeons Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs), we collected data on adult patients who received a centrifugal-flow left ventricular assist device as a primary isolated implant between January 1, 2017, and September 30, 2019. Major NAEs were defined as transient ischemic attack, ischemic cerebrovascular accident, or hemorrhagic cerebrovascular accident. The association of HVAD with risk of NAE in the first year after implant was evaluated using propensity score matching to balance for preimplant risk factors. After matching, freedom from first major NAE in the HM3 and HVAD cohorts was compared with Kaplan-Meier curves. A secondary analysis using multivariable multiphase hazard models was used to identify predictors of NAE, which uses a data-driven parametric fit of the early declining and constant phase hazards and the associations of risk factor with either phase. Results: Of 6205 included patients, 3129 (50.4%) received the HM3 and 3076 (49.6%) received the HVAD. MedianAbstract : Background: Ischemic and hemorrhagic cerebrovascular accidents remain common among patients with centrifugal-flow left ventricular assist devices, despite improvements in survival and device longevity. We compared the incidence of neurologic adverse events (NAEs) associated with 2 contemporary centrifugal-flow left ventricular assist devices: the Abbott HeartMate3 (HM3) and the Medtronic HeartWare HVAD (HVAD). Methods: Using the Society of Thoracic Surgeons Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs), we collected data on adult patients who received a centrifugal-flow left ventricular assist device as a primary isolated implant between January 1, 2017, and September 30, 2019. Major NAEs were defined as transient ischemic attack, ischemic cerebrovascular accident, or hemorrhagic cerebrovascular accident. The association of HVAD with risk of NAE in the first year after implant was evaluated using propensity score matching to balance for preimplant risk factors. After matching, freedom from first major NAE in the HM3 and HVAD cohorts was compared with Kaplan-Meier curves. A secondary analysis using multivariable multiphase hazard models was used to identify predictors of NAE, which uses a data-driven parametric fit of the early declining and constant phase hazards and the associations of risk factor with either phase. Results: Of 6205 included patients, 3129 (50.4%) received the HM3 and 3076 (49.6%) received the HVAD. Median follow-up was 9 and 12 months (HM3 and HVAD, respectively). Patients receiving HVAD had more major NAEs (16.4% versus 6.4%, P <0.001) as well as each subtype (transient ischemic attack: 3.3% versus 1.0%, P <0.001; ischemic cerebrovascular accident: 7.7% versus 3.4%, P <0.001; hemorrhagic cerebrovascular accident: 7.2% versus 2.0%, P <0.001) than did patients receiving HM3. A propensity-matched cohort balanced for preimplant risk factors showed that HVAD was associated with higher probabilities of major NAEs (% freedom from NAE 82% versus 92%, P <0.001). Device type was not significantly associated with NAEs in the early hazard phase, but HVAD was associated with higher incidence of major NAEs during the constant hazard phase (hazard ratio, 5.71 [CI, 3.90–8.36]). Conclusions: HM3 is associated with lower hazard of major NAEs than is HVAD beyond the early postimplantation period and during the constant hazard phase. Defining the explanation for this observation will inform device selection for individual patients. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 144:Issue 10(2021)
- Journal:
- Circulation
- Issue:
- Volume 144:Issue 10(2021)
- Issue Display:
- Volume 144, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 144
- Issue:
- 10
- Issue Sort Value:
- 2021-0144-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09-07
- Subjects:
- heart failure -- stroke
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.121.055716 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24931.xml