Multiparametric Implantable Cardioverter-Defibrillator Algorithm for Heart Failure Risk Stratification and Management: An Analysis in Clinical Practice. (October 2021)
- Record Type:
- Journal Article
- Title:
- Multiparametric Implantable Cardioverter-Defibrillator Algorithm for Heart Failure Risk Stratification and Management: An Analysis in Clinical Practice. (October 2021)
- Main Title:
- Multiparametric Implantable Cardioverter-Defibrillator Algorithm for Heart Failure Risk Stratification and Management
- Authors:
- Calò, Leonardo
Bianchi, Valter
Ferraioli, Donatella
Santini, Luca
Dello Russo, Antonio
Carriere, Cosimo
Santobuono, Vincenzo Ezio
Andreoli, Chiara
La Greca, Carmelo
Arena, Giuseppe
Talarico, Antonello
Pisanò, Ennio
Santoro, Amato
Giammaria, Massimo
Ziacchi, Matteo
Viscusi, Miguel
De Ruvo, Ermenegildo
Campari, Monica
Valsecchi, Sergio
D'Onofrio, Antonio - Abstract:
- Abstract : Background: The HeartLogic algorithm combines multiple implantable cardioverter-defibrillator sensors to identify patients at risk of heart failure (HF) events. We sought to evaluate the risk stratification ability of this algorithm in clinical practice. We also analyzed the alert management strategies adopted in the study group and their association with the occurrence of HF events. Methods: The HeartLogic feature was activated in 366 implantable cardioverter-defibrillator and cardiac resynchronization therapy implantable cardioverter-defibrillator patients at 22 centers. The median follow-up was 11 months [25th–75th percentile: 6–16]. The HeartLogic algorithm calculates a daily HF index and identifies periods IN alert state on the basis of a configurable threshold. Results: The HeartLogic index crossed the threshold value 273 times (0.76 alerts/patient-year) in 150 patients. The time IN alert state was 11% of the total observation period. Patients experienced 36 HF hospitalizations, and 8 patients died of HF during the observation period. Thirty-five events were associated with the IN alert state (0.92 events/patient-year versus 0.03 events/patient-year in the OUT of alert state). The hazard ratio in the IN/OUT of alert state comparison was (hazard ratio, 24.53 [95% CI, 8.55–70.38], P <0.001), after adjustment for baseline clinical confounders. Alerts followed by clinical actions were associated with less HF events (hazard ratio, 0.37 [95% CI, 0.14–0.99], PAbstract : Background: The HeartLogic algorithm combines multiple implantable cardioverter-defibrillator sensors to identify patients at risk of heart failure (HF) events. We sought to evaluate the risk stratification ability of this algorithm in clinical practice. We also analyzed the alert management strategies adopted in the study group and their association with the occurrence of HF events. Methods: The HeartLogic feature was activated in 366 implantable cardioverter-defibrillator and cardiac resynchronization therapy implantable cardioverter-defibrillator patients at 22 centers. The median follow-up was 11 months [25th–75th percentile: 6–16]. The HeartLogic algorithm calculates a daily HF index and identifies periods IN alert state on the basis of a configurable threshold. Results: The HeartLogic index crossed the threshold value 273 times (0.76 alerts/patient-year) in 150 patients. The time IN alert state was 11% of the total observation period. Patients experienced 36 HF hospitalizations, and 8 patients died of HF during the observation period. Thirty-five events were associated with the IN alert state (0.92 events/patient-year versus 0.03 events/patient-year in the OUT of alert state). The hazard ratio in the IN/OUT of alert state comparison was (hazard ratio, 24.53 [95% CI, 8.55–70.38], P <0.001), after adjustment for baseline clinical confounders. Alerts followed by clinical actions were associated with less HF events (hazard ratio, 0.37 [95% CI, 0.14–0.99], P =0.047). No differences in event rates were observed between in-office and remote alert management. Conclusions: This multiparametric algorithm identifies patients during periods of significantly increased risk of HF events. The rate of HF events seemed lower when clinical actions were undertaken in response to alerts. Extra in-office visits did not seem to be required to effectively manage HeartLogic alerts. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02275637. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 14:Number 10(2021)
- Journal:
- Circulation
- Issue:
- Volume 14:Number 10(2021)
- Issue Display:
- Volume 14, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 14
- Issue:
- 10
- Issue Sort Value:
- 2021-0014-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- algorithm -- defibrillator, implantable -- heart failure -- hospitalization -- risk
Heart failure -- Periodicals
616.129005 - Journal URLs:
- http://circheartfailure.ahajournals.org/content/current ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCHEARTFAILURE.120.008134 ↗
- Languages:
- English
- ISSNs:
- 1941-3289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.282000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24960.xml