Comparison of Horizontal Corneal Diameter Measurements Using Orbscan IIz, OPD Scan III, and IOLMaster 700. Issue 10 (October 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of Horizontal Corneal Diameter Measurements Using Orbscan IIz, OPD Scan III, and IOLMaster 700. Issue 10 (October 2021)
- Main Title:
- Comparison of Horizontal Corneal Diameter Measurements Using Orbscan IIz, OPD Scan III, and IOLMaster 700
- Authors:
- Cruz, Sebastian
Valenzuela, Felipe
Stoppel, Juan
Maul, Eugenio
Gibbons, Allister - Abstract:
- Abstract : Purpose: To compare three automated devices for measuring the horizontal corneal diameter (white to white [WTW]). Methods: In 65 eyes of 38 patients, the WTW distance was measured independently by three examiners using the following techniques: Orbscan IIz tomography system (Bausch & Lomb), IOLMaster 700 (Carl Zeiss Meditec), and OPD Scan III (NIDEK). We tested for systematic differences in measurements and estimated the limits of agreement (LoA) using linear mixed-effects models. Results: The mean WTW distance was 11.8±0.40 mm with Orbscan IIz, 12.1±0.5 mm with IOLMaster 700 and 12.0±0.4 mm with OPD Scan III. The mean difference between IOLMaster 700 and Orbscan IIz was 0.33 (95% CI, 0.28 to 0.38; P <0.001), between OPD Scan III and Orbscan IIz was 0.24 mm (95% CI, 0.21 to 0.28; P <0.001), and between IOL Master 700 and OPD Scan III was 0.09 (95% CI, 0.05 to 0.12; P <0.001). The 95% LoA for Orbscan IIz versus IOLMaster 700 was −0.69 to 0.03 mm, Orbscan IIz versus OPD Scan III was −0.52 to −0.03 mm, and OPD versus IOLMaster 700 was −0.39 to 0.22 mm. Conclusions: The data suggest that these devices are not interchangeable for usual clinical practice. Adjustments based on mean differences were not enough to compensate for interinstrument discrepancy in WTW measurements.
- Is Part Of:
- Eye & contact lens. Volume 47:Issue 10(2021)
- Journal:
- Eye & contact lens
- Issue:
- Volume 47:Issue 10(2021)
- Issue Display:
- Volume 47, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 47
- Issue:
- 10
- Issue Sort Value:
- 2021-0047-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- Corneal diameter -- White-to-white distance -- Orbscan IIz -- IOLMaster 700 -- OPD scan III
Contact lenses -- Periodicals
Intraocular lenses -- Periodicals
Orthokeratology -- Periodicals
Anterior segment (Eye) -- Diseases -- Periodicals
617.7523 - Journal URLs:
- http://journals.lww.com/claojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICL.0000000000000786 ↗
- Languages:
- English
- ISSNs:
- 1542-2321
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3854.587000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24946.xml