Evaluation of Iterative Denoising 3-Dimensional T2-Weighted Turbo Spin Echo for the Diagnosis of Deep Infiltrating Endometriosis. Issue 10 (October 2021)
- Record Type:
- Journal Article
- Title:
- Evaluation of Iterative Denoising 3-Dimensional T2-Weighted Turbo Spin Echo for the Diagnosis of Deep Infiltrating Endometriosis. Issue 10 (October 2021)
- Main Title:
- Evaluation of Iterative Denoising 3-Dimensional T2-Weighted Turbo Spin Echo for the Diagnosis of Deep Infiltrating Endometriosis
- Authors:
- Florin, Marie
Vaussy, Alexis
Macron, Laurent
Bazot, Marc
Stemmer, Alto
Pinar, Ugo
Jarboui, Lamia - Abstract:
- Abstract : Objectives: The primary end point of this study was to evaluate the image quality and reliability of a highly accelerated 3-dimensional T2 turbo spin echo (3D-T2-TSE) sequence with prototype iterative denoising (ID) reconstruction compared with conventional 2D T2 sequences for the diagnosis of deep infiltrating endometriosis (DIE). The secondary end point was to demonstrate the 3D-T2-TSE sequence image quality improvement using ID reconstruction. Material and Methods: Patients were prospectively enrolled to our institution for pelvis magnetic resonance imaging because of a suspicion of endometriosis over a 4-month period. Both conventional 2D-T2 (sagittal, axial, coronal T2 oblique to the cervix) and 3D-T2-TSE sequences were performed with a scan time of 7 minutes 43 seconds and 4 minutes 58 seconds, respectively. Reconstructions with prototype ID (3D-T2-denoised) and without prototype ID (3D-T2) were generated inline at the end of the acquisition. Two radiologists independently evaluated the image quality of 3D-T2, 3D-T2-denoised, and 2D-T2 sequences. Diagnosis confidence of DIE was evaluated for both 3D-T2-denoised and 2D-T2 sequences. Intraobserver and interobserver agreements were calculated using Cohen κ coefficient. Results: Ninety female patients were included. Both readers found that the ID algorithm significantly improved the image quality and decreased the artifacts of 3D-T2-denoised compared with 3D-T2 sequences ( P < 0.001). A significant image qualityAbstract : Objectives: The primary end point of this study was to evaluate the image quality and reliability of a highly accelerated 3-dimensional T2 turbo spin echo (3D-T2-TSE) sequence with prototype iterative denoising (ID) reconstruction compared with conventional 2D T2 sequences for the diagnosis of deep infiltrating endometriosis (DIE). The secondary end point was to demonstrate the 3D-T2-TSE sequence image quality improvement using ID reconstruction. Material and Methods: Patients were prospectively enrolled to our institution for pelvis magnetic resonance imaging because of a suspicion of endometriosis over a 4-month period. Both conventional 2D-T2 (sagittal, axial, coronal T2 oblique to the cervix) and 3D-T2-TSE sequences were performed with a scan time of 7 minutes 43 seconds and 4 minutes 58 seconds, respectively. Reconstructions with prototype ID (3D-T2-denoised) and without prototype ID (3D-T2) were generated inline at the end of the acquisition. Two radiologists independently evaluated the image quality of 3D-T2, 3D-T2-denoised, and 2D-T2 sequences. Diagnosis confidence of DIE was evaluated for both 3D-T2-denoised and 2D-T2 sequences. Intraobserver and interobserver agreements were calculated using Cohen κ coefficient. Results: Ninety female patients were included. Both readers found that the ID algorithm significantly improved the image quality and decreased the artifacts of 3D-T2-denoised compared with 3D-T2 sequences ( P < 0.001). A significant image quality improvement was found by 1 radiologist for 3D-T2-denoised compared with 2D-T2 sequences ( P = 0.002), whereas the other reader evidenced no significant difference. The interobserver agreement of 3D-T2-denoised and 2D-T2 sequences was 0.84 (0.73–0.95) and 0.78 (0.65–0.9), respectively, for the diagnosis of DIE. Intraobserver agreement for readers 1 and 2 was 0.86 (0.79–1) and 0.83 (0.76–1), respectively. For all localization of DIE, interobserver and intraobserver agreements were either almost perfect or substantial for both 3D-T2-denoised and 2D-T2 sequences. Conclusions: Three-dimensional T2-denoised imaging is a promising tool to replace conventional 2D-T2 sequences, offering a significant scan time reduction without compromising image quality or diagnosis information for the assessment of DIE. … (more)
- Is Part Of:
- Investigative radiology. Volume 56:Issue 10(2021)
- Journal:
- Investigative radiology
- Issue:
- Volume 56:Issue 10(2021)
- Issue Display:
- Volume 56, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 56
- Issue:
- 10
- Issue Sort Value:
- 2021-0056-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- endometriosis -- pelvis MRI -- iterative denoising -- imaging performance
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000786 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24941.xml