Low intensity ultrasound targeted microbubble destruction assists MSCs delivery and improves neural function in brain ischaemic rats. (15th March 2020)
- Record Type:
- Journal Article
- Title:
- Low intensity ultrasound targeted microbubble destruction assists MSCs delivery and improves neural function in brain ischaemic rats. (15th March 2020)
- Main Title:
- Low intensity ultrasound targeted microbubble destruction assists MSCs delivery and improves neural function in brain ischaemic rats
- Authors:
- Cui, Hai
Zhu, Qiong
Xie, Qinli
Liu, Zheng
Gao, Yunhua
He, Ying
Tan, Xi
Xu, Yali - Abstract:
- Abstract: Background and purpose: The present study aimed to explore the feasibility and efficacy of the targeted non-invasive implantation of mesenchymal stromal cells (MSCs) by low-intensity ultrasound-targeted microbubble destruction (LI-UTMD) assisted blood–brain barrier (BBB) opening and its improvement on neurobehavioural outcomes in brain ischaemic rats. Methods: A transcranial irradiation of low-intensity ultrasound by diagnostic devices was performed, and lipid microbubbles (MBs) and MSCs were simultaneously infused. Then, the MSC transmigration from brain vessels to parenchyma was demonstrated, and MSCs were statistically analysed on days 1, 4, 7 and 14. Behavioural function was statistically analysed. Results: The extra-vascular leakage of lanthanum and EB was observed at the brain ischaemic area receiving ultrasound. MSCs were observed at the ultrasound irradiated brain hemisphere, and the number of MSCs in LI-UTMD assisted MSCs group was significantly higher than that in the MSCs group ( p < .01). The attachment, traversing and trans-migration of MSCs across the BBB were recorded. Neuro-behavioural function was improved with this approach. Conclusions: The transcranial irradiation of low intensity ultrasound targeted MBs destruction on brain ischaemic rats might be a safe and efficient BBB opening approach to prompt the successful delivery of MSCs into the targeted area of brain ischaemia, and ameliorate neurological function.
- Is Part Of:
- Journal of drug targeting. Volume 28:Number 3(2020)
- Journal:
- Journal of drug targeting
- Issue:
- Volume 28:Number 3(2020)
- Issue Display:
- Volume 28, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 28
- Issue:
- 3
- Issue Sort Value:
- 2020-0028-0003-0000
- Page Start:
- 320
- Page End:
- 329
- Publication Date:
- 2020-03-15
- Subjects:
- MSCs implantation -- brain ischaemia -- neural function -- low intensity ultrasound targeted microbubbles destruction -- diagnostic devices
Drug delivery systems -- Periodicals
Drug Delivery Systems
Vehicles
Drug Administration Routes
Drug Evaluation
615.7 - Journal URLs:
- http://informahealthcare.com/loi/drt ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/1061186X.2019.1656724 ↗
- Languages:
- English
- ISSNs:
- 1061-186X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4970.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24951.xml