Photon-Counting Computed Tomography for Coronary Stent Imaging: In Vitro Evaluation of 28 Coronary Stents. Issue 10 (October 2021)
- Record Type:
- Journal Article
- Title:
- Photon-Counting Computed Tomography for Coronary Stent Imaging: In Vitro Evaluation of 28 Coronary Stents. Issue 10 (October 2021)
- Main Title:
- Photon-Counting Computed Tomography for Coronary Stent Imaging
- Authors:
- Petritsch, Bernhard
Petri, Nils
Weng, Andreas M.
Petersilka, Martin
Allmendinger, Thomas
Bley, Thorsten A.
Gassenmaier, Tobias - Abstract:
- Abstract : Objectives: The aim of this study was to assess in-stent lumen visibility and quantitative image characteristics of different coronary stents using a novel photon-counting detector (PCD) computed tomography (CT) system in comparison to a state-of-the-art energy-integrating detector (EID) CT scanner. Materials and Methods: In this in vitro phantom study, 28 different coronary stents ranging from 2.25 to 4.5 mm lumen diameter were expanded into plastic tubes filled with contrast agent. Stent-containing plastic tubes were positioned in a custom-made emulsion-filled phantom, which was inserted into an anthropomorphic phantom simulating a medium-sized patient. Computed tomography scans were acquired parallel to the scanners' z axis using a novel cadmium telluride–based PCD CT system (SOMATOM CountPlus; Siemens Healthcare GmbH, Forchheim Germany), operating in 2 different modes (standard-resolution mode [SR] and ultra-high-resolution [UHR] mode), and a latest generation dual-source EID CT system (SOMATOM Force; Siemens Healthcare GmbH, Forchheim). CTDIvol -matched images were reconstructed with comparable convolution kernels and using the same reconstruction parameters. In-stent lumen visibility (in %), increase in in-stent attenuation (expressed as Δ in-stent CT attenuation), and image noise (in Hounsfield unit) were manually measured. Parts of the image analysis (in-stent lumen visibility) were additionally performed in an automated way. Differences were tested usingAbstract : Objectives: The aim of this study was to assess in-stent lumen visibility and quantitative image characteristics of different coronary stents using a novel photon-counting detector (PCD) computed tomography (CT) system in comparison to a state-of-the-art energy-integrating detector (EID) CT scanner. Materials and Methods: In this in vitro phantom study, 28 different coronary stents ranging from 2.25 to 4.5 mm lumen diameter were expanded into plastic tubes filled with contrast agent. Stent-containing plastic tubes were positioned in a custom-made emulsion-filled phantom, which was inserted into an anthropomorphic phantom simulating a medium-sized patient. Computed tomography scans were acquired parallel to the scanners' z axis using a novel cadmium telluride–based PCD CT system (SOMATOM CountPlus; Siemens Healthcare GmbH, Forchheim Germany), operating in 2 different modes (standard-resolution mode [SR] and ultra-high-resolution [UHR] mode), and a latest generation dual-source EID CT system (SOMATOM Force; Siemens Healthcare GmbH, Forchheim). CTDIvol -matched images were reconstructed with comparable convolution kernels and using the same reconstruction parameters. In-stent lumen visibility (in %), increase in in-stent attenuation (expressed as Δ in-stent CT attenuation), and image noise (in Hounsfield unit) were manually measured. Parts of the image analysis (in-stent lumen visibility) were additionally performed in an automated way. Differences were tested using Wilcoxon signed rank test. Results: The best in-stent lumen visibility was achieved with the PCD-UHR mode and the lowest noise levels with the PCD-SR mode. The median in-stent lumen visibility was significantly higher ( P < 0.001) with PCD (SR, 66.7%; interquartile range [IQR], 63.3–72.3; UHR, 68.9%; IQR, 64.4–74.4) compared with EID (65.4%; IQR, 62.2–70.4). The Δ in-stent CT attenuation was significantly lower for PCD in both SR (78 HU; IQR, 46–108; P = 0.024) and UHR (85 HU; IQR, 59–113; P = 0.006) compared with EID (108 HU; IQR, 85–126). Image noise was significantly lower ( P < 0.001) for PCD-SR (21 HU; IQR, 21–21) compared with EID images (25 HU; IQR, 24–25.0). Conclusions: The PCD provides superior in-stent lumen visibility and quantitative image characteristics when compared with conventional EID. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Investigative radiology. Volume 56:Issue 10(2021)
- Journal:
- Investigative radiology
- Issue:
- Volume 56:Issue 10(2021)
- Issue Display:
- Volume 56, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 56
- Issue:
- 10
- Issue Sort Value:
- 2021-0056-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- photon-counting -- detector -- computed tomography -- coronary artery stents -- cardiac
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000787 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24941.xml