Motion‐robust, blood‐suppressed, reduced‐distortion diffusion MRI of the liver. Issue 3 (20th November 2022)
- Record Type:
- Journal Article
- Title:
- Motion‐robust, blood‐suppressed, reduced‐distortion diffusion MRI of the liver. Issue 3 (20th November 2022)
- Main Title:
- Motion‐robust, blood‐suppressed, reduced‐distortion diffusion MRI of the liver
- Authors:
- Geng, Ruiqi
Zhang, Yuxin
Rice, James
Muehler, Matthias R.
Starekova, Jitka
Rutkowski, David R.
Uboha, Nataliya V.
Pirasteh, Ali
Roldán‐Alzate, Alejandro
Guidon, Arnaud
Hernando, Diego - Abstract:
- Abstract : Purpose: To evaluate feasibility and reproducibility of liver diffusion‐weighted (DW) MRI using cardiac‐motion‐robust, blood‐suppressed, reduced‐distortion techniques. Methods: DW‐MRI data were acquired at 3T in an anatomically accurate liver phantom including controlled pulsatile motion, in eight healthy volunteers and four patients with known or suspected liver metastases. Standard monopolar and motion‐robust (M1‐nulled, and M1‐optimized) DW gradient waveforms were each acquired with single‐shot echo‐planar imaging (ssEPI) and multishot EPI (msEPI). In the motion phantom, apparent diffusion coefficient (ADC) was measured in the motion‐affected volume. In healthy volunteers, ADC was measured in the left and right liver lobes separately to evaluate ADC reproducibility between the two lobes. Image distortions were quantified using the normalized cross‐correlation coefficient, with an undistorted T2‐weighted reference. Results: In the motion phantom, ADC mean and SD in motion‐affected volumes substantially increased with increasing motion for monopolar waveforms. ADC remained stable in the presence of increasing motion when using motion‐robust waveforms. M1‐optimized waveforms suppressed slow flow signal present with M1‐nulled waveforms. In healthy volunteers, monopolar waveforms generated significantly different ADC measurements between left and right liver lobes ( p = 0 . 0078 $$ p=0.0078 $$, reproducibility coefficients (RPC) = 470 × 1 0 − 6 $$ 470\timesAbstract : Purpose: To evaluate feasibility and reproducibility of liver diffusion‐weighted (DW) MRI using cardiac‐motion‐robust, blood‐suppressed, reduced‐distortion techniques. Methods: DW‐MRI data were acquired at 3T in an anatomically accurate liver phantom including controlled pulsatile motion, in eight healthy volunteers and four patients with known or suspected liver metastases. Standard monopolar and motion‐robust (M1‐nulled, and M1‐optimized) DW gradient waveforms were each acquired with single‐shot echo‐planar imaging (ssEPI) and multishot EPI (msEPI). In the motion phantom, apparent diffusion coefficient (ADC) was measured in the motion‐affected volume. In healthy volunteers, ADC was measured in the left and right liver lobes separately to evaluate ADC reproducibility between the two lobes. Image distortions were quantified using the normalized cross‐correlation coefficient, with an undistorted T2‐weighted reference. Results: In the motion phantom, ADC mean and SD in motion‐affected volumes substantially increased with increasing motion for monopolar waveforms. ADC remained stable in the presence of increasing motion when using motion‐robust waveforms. M1‐optimized waveforms suppressed slow flow signal present with M1‐nulled waveforms. In healthy volunteers, monopolar waveforms generated significantly different ADC measurements between left and right liver lobes ( p = 0 . 0078 $$ p=0.0078 $$, reproducibility coefficients (RPC) = 470 × 1 0 − 6 $$ 470\times 1{0}^{-6} $$ mm 2 $$ {}^2 $$ /s for monopolar‐msEPI), while M1‐optimized waveforms showed more reproducible ADC values ( p = 0 . 29 $$ p=0.29 $$, RPC = 220 × 1 0 − 6 $$ \mathrm{RPC}=220\times 1{0}^{-6} $$ mm 2 $$ {}^2 $$ /s for M1‐optimized‐msEPI). In phantom and healthy volunteer studies, motion‐robust acquisitions with msEPI showed significantly reduced image distortion ( p < 0 . 001 $$ p<0.001 $$ ) compared to ssEPI. Patient scans showed reduction of wormhole artifacts when combining M1‐optimized waveforms with msEPI. Conclusion: Synergistic effects of combined M1‐optimized diffusion waveforms and msEPI acquisitions enable reproducible liver DWI with motion robustness, blood signal suppression, and reduced distortion. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 3(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 3(2023)
- Issue Display:
- Volume 89, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 3
- Issue Sort Value:
- 2023-0089-0003-0000
- Page Start:
- 908
- Page End:
- 921
- Publication Date:
- 2022-11-20
- Subjects:
- diffusion -- liver -- motion‐robust -- multishot -- phantom
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29531 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24965.xml