Compatibility of a novel filter paper-based bio-safe sputum transport kit with line probe assay for diagnosing drug-resistant tuberculosis: a single-site evaluation study. Issue 3 (2nd August 2021)
- Record Type:
- Journal Article
- Title:
- Compatibility of a novel filter paper-based bio-safe sputum transport kit with line probe assay for diagnosing drug-resistant tuberculosis: a single-site evaluation study. Issue 3 (2nd August 2021)
- Main Title:
- Compatibility of a novel filter paper-based bio-safe sputum transport kit with line probe assay for diagnosing drug-resistant tuberculosis: a single-site evaluation study
- Authors:
- Anthwal, Divya
Gupta, Rakesh Kumar
Singhal, Ritu
Bhalla, Manpreet
Verma, Ajoy Kumar
Khayyam, Khalid Umar
Myneedu, Vithal Prasad
Sarin, Rohit
Gupta, Ashawant
Gupta, Nalini Kant
Singh, Manjula
Sivaswami Tyagi, Jaya
Haldar, Sagarika - Abstract:
- Background: Near-patient access to appropriate tests is a major obstacle for the efficient diagnosis of tuberculosis (TB) and associated drug resistance. Methods: We recently developed the "TB Concentration & Transport" kit for bio-safe, ambient-temperature transportation of dried sputum on Trans -Filter, and the "TB DNA Extraction" kit for DNA extraction from Trans -Filter for determining drug resistance by DNA sequencing. In the present study, we evaluated the compatibility of Kit-extracted DNA with Hain's line probe assays (LPAs), which are endorsed by National TB programmes for the detection of drug resistance in sputum collected from presumptive multidrug-resistant TB patients ( n =207). Results: Trans -Filter-extracted DNA was seamlessly integrated with the LPA protocol (Kit-LPA). The sensitivity of Kit-LPA for determining drug resistance was 83.3% for rifampicin (95% CI 52–98%), 77.7% for isoniazid (95% CI 52–94%), 85.7% for fluoroquinolones (95% CI 42–100%) and 66.6% for aminoglycosides (95% CI 9–99%), with a specificity range of 93.7% (95% CI 87–97) to 99.1% (95% CI 95–100) using phenotypic drug susceptibility testing (DST) as a reference standard. A high degree of concordance was noted between results obtained from Kit-LPA and LPA (99% to 100% (κ value: 0.83–1.0)). Conclusions: This study demonstrates successful integration of our developed kits with LPA. The adoption of these kits across Designated Microscopy Centres in India can potentially overcome the existingBackground: Near-patient access to appropriate tests is a major obstacle for the efficient diagnosis of tuberculosis (TB) and associated drug resistance. Methods: We recently developed the "TB Concentration & Transport" kit for bio-safe, ambient-temperature transportation of dried sputum on Trans -Filter, and the "TB DNA Extraction" kit for DNA extraction from Trans -Filter for determining drug resistance by DNA sequencing. In the present study, we evaluated the compatibility of Kit-extracted DNA with Hain's line probe assays (LPAs), which are endorsed by National TB programmes for the detection of drug resistance in sputum collected from presumptive multidrug-resistant TB patients ( n =207). Results: Trans -Filter-extracted DNA was seamlessly integrated with the LPA protocol (Kit-LPA). The sensitivity of Kit-LPA for determining drug resistance was 83.3% for rifampicin (95% CI 52–98%), 77.7% for isoniazid (95% CI 52–94%), 85.7% for fluoroquinolones (95% CI 42–100%) and 66.6% for aminoglycosides (95% CI 9–99%), with a specificity range of 93.7% (95% CI 87–97) to 99.1% (95% CI 95–100) using phenotypic drug susceptibility testing (DST) as a reference standard. A high degree of concordance was noted between results obtained from Kit-LPA and LPA (99% to 100% (κ value: 0.83–1.0)). Conclusions: This study demonstrates successful integration of our developed kits with LPA. The adoption of these kits across Designated Microscopy Centres in India can potentially overcome the existing challenge of transporting infectious sputum at controlled temperature to centralised testing laboratories and can provide rapid near-patient cost-effective "Universal DST" services to TB subjects residing in remote areas. The adoption of bio-safe "TB Concentration & Transport" kit by Microscopy Centres can potentially overcome the challenge of transporting infectious sputum to central laboratories and provide universal DST services to TB subjects residing in remote areas. https://bit.ly/2QrQ5qL … (more)
- Is Part Of:
- ERJ open research. Volume 7:Issue 3(2021)
- Journal:
- ERJ open research
- Issue:
- Volume 7:Issue 3(2021)
- Issue Display:
- Volume 7, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 7
- Issue:
- 3
- Issue Sort Value:
- 2021-0007-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08-02
- Subjects:
- Respiratory organs -- Diseases -- Periodicals
Respiration -- Periodicals
Respiration
Respiratory organs -- Diseases
Respiratory organs -- Diseases -- Treatment
Respiratory Tract Diseases
Electronic journals
Fulltext
Internet Resources
Periodicals
Periodical
616.2005 - Journal URLs:
- http://openres.ersjournals.com/ ↗
http://bibpurl.oclc.org/web/76947 ↗ - DOI:
- 10.1183/23120541.00137-2021 ↗
- Languages:
- English
- ISSNs:
- 2312-0541
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 24833.xml