Classifying signals from a wearable accelerometer device to measure respiratory rate. Issue 2 (26th April 2021)
- Record Type:
- Journal Article
- Title:
- Classifying signals from a wearable accelerometer device to measure respiratory rate. Issue 2 (26th April 2021)
- Main Title:
- Classifying signals from a wearable accelerometer device to measure respiratory rate
- Authors:
- Drummond, Gordon B.
Fischer, Darius
Lees, Margaret
Bates, Andrew
Mann, Janek
Arvind, D.K. - Abstract:
- Background: Automatic measurement of respiratory rate in general hospital patients is difficult. Patient movement degrades the signal and variation of the breathing cycle means that accurate observation for ≥60 s is needed for adequate precision. Methods: We studied acutely ill patients recently admitted to a teaching hospital. Breath duration was measured from a triaxial accelerometer attached to the chest wall and compared with a signal from a nasal cannula. We randomly divided the patient records into a training (n=54) and a test set (n=7). We used machine learning to train a neural network to select reliable signals, automatically identifying signal features associated with accurate measurement of respiratory rate. We used the test records to assess the accuracy of the device, indicated by the median absolute difference between respiratory rates, provided by the accelerometer and by the nasal cannula. Results: In the test set of patients, machine classification of the respiratory signal reduced the median absolute difference (interquartile range) from 1.25 (0.56–2.18) to 0.48 (0.30–0.78) breaths per min. 50% of the recording periods were rejected as unreliable and in one patient, only 10% of the signal time was classified as reliable. However, even only 10% of observation time would allow accurate measurement for 6 min in an hour of recording, giving greater reliability than nurse charting, which is based on much less observation time. Conclusion: Signals from aBackground: Automatic measurement of respiratory rate in general hospital patients is difficult. Patient movement degrades the signal and variation of the breathing cycle means that accurate observation for ≥60 s is needed for adequate precision. Methods: We studied acutely ill patients recently admitted to a teaching hospital. Breath duration was measured from a triaxial accelerometer attached to the chest wall and compared with a signal from a nasal cannula. We randomly divided the patient records into a training (n=54) and a test set (n=7). We used machine learning to train a neural network to select reliable signals, automatically identifying signal features associated with accurate measurement of respiratory rate. We used the test records to assess the accuracy of the device, indicated by the median absolute difference between respiratory rates, provided by the accelerometer and by the nasal cannula. Results: In the test set of patients, machine classification of the respiratory signal reduced the median absolute difference (interquartile range) from 1.25 (0.56–2.18) to 0.48 (0.30–0.78) breaths per min. 50% of the recording periods were rejected as unreliable and in one patient, only 10% of the signal time was classified as reliable. However, even only 10% of observation time would allow accurate measurement for 6 min in an hour of recording, giving greater reliability than nurse charting, which is based on much less observation time. Conclusion: Signals from a body-mounted accelerometer yield accurate measures of respiratory rate, which could improve automatic illness scoring in adult hospital patients. A machine learning method was developed to classify sections of breathing records from acutely ill patients wearing a small wireless motion sensor. This would allow accurate and automatic measurement, recording, and charting of respiratory rate. https://bit.ly/301P8XW … (more)
- Is Part Of:
- ERJ open research. Volume 7:Issue 2(2021)
- Journal:
- ERJ open research
- Issue:
- Volume 7:Issue 2(2021)
- Issue Display:
- Volume 7, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 7
- Issue:
- 2
- Issue Sort Value:
- 2021-0007-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04-26
- Subjects:
- Respiratory organs -- Diseases -- Periodicals
Respiration -- Periodicals
Respiration
Respiratory organs -- Diseases
Respiratory organs -- Diseases -- Treatment
Respiratory Tract Diseases
Electronic journals
Fulltext
Internet Resources
Periodicals
Periodical
616.2005 - Journal URLs:
- http://openres.ersjournals.com/ ↗
http://bibpurl.oclc.org/web/76947 ↗ - DOI:
- 10.1183/23120541.00681-2020 ↗
- Languages:
- English
- ISSNs:
- 2312-0541
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 24873.xml