In-Human Report of S2 Alar-Iliac Screw Placement Using Augmented Reality Assistance. Issue 1 (4th January 2023)
- Record Type:
- Journal Article
- Title:
- In-Human Report of S2 Alar-Iliac Screw Placement Using Augmented Reality Assistance. Issue 1 (4th January 2023)
- Main Title:
- In-Human Report of S2 Alar-Iliac Screw Placement Using Augmented Reality Assistance
- Authors:
- Judy, Brendan F.
Liu, Ann
Jin, Yike
Ronkon, Charles
Khan, Majid
Cottrill, Ethan
Ehresman, Jeff
Pennington, Zach
Bydon, Ali
Lo, Sheng-Fu L.
Sciubba, Daniel M.
Molina, Camilo A.
Witham, Timothy F. - Abstract:
- Abstract : BACKGROUND: S2 alar-iliac (S2AI) screws provide spinopelvic fixation with the advantages of minimized dissection, easier rod contouring, and decreased symptomatic screw-head prominence. However, placement of S2AI screws may be challenging because of the anatomy of the lumbosacral junction. Augmented reality is a nascent technology that may enhance placement of S2AI screws. OBJECTIVE: To report the first in-human placement of augmented reality (AR)–assisted S2 alar-iliac screws and evaluate the accuracy of screw placement. METHODS: A retrospective review was performed of patients who underwent AR-assisted S2AI screw placement. All surgeries were performed by 2 neurosurgeons using an AR head-mounted display (Xvision, Augmedics). Screw accuracy was analyzed in a blinded fashion by an independent neuroradiologist using the cortical breach grading scale. RESULTS: Twelve patients underwent AR-assisted S2AI screw placement for a total of 23 screws. Indications for surgery included deformity, degenerative disease, and tumor. Twenty-two screws (95.6%) were accurate—defined as grade 0 or grade 1. Twenty-one screws (91.3%) were classified as grade 0, 1 screw (4.3%) was grade 1, and 1 screw (4.3%) was grade 3. All breaches were asymptomatic. CONCLUSION: AR-assisted S2AI screw placement had an overall accuracy rate of 95.6% (grade 0 and grade 1 screws) in a cohort of 12 patients and 23 screws. This compares favorably with freehand and robotic placement. 1, 2 AR enables spineAbstract : BACKGROUND: S2 alar-iliac (S2AI) screws provide spinopelvic fixation with the advantages of minimized dissection, easier rod contouring, and decreased symptomatic screw-head prominence. However, placement of S2AI screws may be challenging because of the anatomy of the lumbosacral junction. Augmented reality is a nascent technology that may enhance placement of S2AI screws. OBJECTIVE: To report the first in-human placement of augmented reality (AR)–assisted S2 alar-iliac screws and evaluate the accuracy of screw placement. METHODS: A retrospective review was performed of patients who underwent AR-assisted S2AI screw placement. All surgeries were performed by 2 neurosurgeons using an AR head-mounted display (Xvision, Augmedics). Screw accuracy was analyzed in a blinded fashion by an independent neuroradiologist using the cortical breach grading scale. RESULTS: Twelve patients underwent AR-assisted S2AI screw placement for a total of 23 screws. Indications for surgery included deformity, degenerative disease, and tumor. Twenty-two screws (95.6%) were accurate—defined as grade 0 or grade 1. Twenty-one screws (91.3%) were classified as grade 0, 1 screw (4.3%) was grade 1, and 1 screw (4.3%) was grade 3. All breaches were asymptomatic. CONCLUSION: AR-assisted S2AI screw placement had an overall accuracy rate of 95.6% (grade 0 and grade 1 screws) in a cohort of 12 patients and 23 screws. This compares favorably with freehand and robotic placement. 1, 2 AR enables spine surgeons to both better visualize anatomy and accurately place spinal instrumentation. Future studies are warranted to research the learning curve and cost analysis of AR-assisted spine surgery. … (more)
- Is Part Of:
- Operative neurosurgery. Volume 24:Issue 1(2023)
- Journal:
- Operative neurosurgery
- Issue:
- Volume 24:Issue 1(2023)
- Issue Display:
- Volume 24, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2023-0024-0001-0000
- Page Start:
- 68
- Page End:
- 73
- Publication Date:
- 2023-01-04
- Subjects:
- Augmented reality -- Sacral alar-iliac screws -- Surgical technique
Nervous system -- Surgery -- Periodicals
617.480590 - Journal URLs:
- https://academic.oup.com/ons/issue ↗
http://journals.lww.com/onsonline/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1227/ons.0000000000000439 ↗
- Languages:
- English
- ISSNs:
- 2332-4252
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6269.380200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24831.xml