A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture. (23rd February 2022)
- Record Type:
- Journal Article
- Title:
- A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture. (23rd February 2022)
- Main Title:
- A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture
- Authors:
- Szkoda-Poliszuk, Klaudia
Załuski, Rafał - Other Names:
- MO Fuhao Academic Editor.
- Abstract:
- Abstract : The aim of this experimental study was to analyze the impact of applying different configurations of the transpedicular fixation system on selected mechanical parameters of the thoracolumbar spine under conditions of its instability (after simulated fracture). Five study groups were tested: physiological, with compression fracture of the vertebra, with two-segment fixation, with three-segment fixation, and with four-segment fixation. Each of the analyzed study groups was subjected to axial compression, flexion, and extension. Based on the conducted experimental tests, the mechanical parameters, i.e., stiffness coefficient and dissipation energy, were determined for all groups under consideration. The stiffness value of two-segment fixation is significantly lower than the physiological value (during flexion and extension). The use of long-segment fixation considered in two configurations (three- and four-segment fixation) may result in excessive stiffness of the system due to the high stiffness values achieved (approx. 25–30% higher than the physiological values in the case of compression and on average 60% higher in the case of flexion). The use of long-segment fixator design shows better results than short-segment fixation. Considering both biomechanical and clinical aspects, three-segment fixation seems to be a compromise solution as it saves the patient from more extensive stiffening of the spinal motion segments.
- Is Part Of:
- Applied bionics and biomechanics. Volume 2022(2022)
- Journal:
- Applied bionics and biomechanics
- Issue:
- Volume 2022(2022)
- Issue Display:
- Volume 2022, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 2022
- Issue:
- 2022
- Issue Sort Value:
- 2022-2022-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02-23
- Subjects:
- Bionics -- Periodicals
Biomechanics -- Periodicals
Biomedical engineering -- Periodicals
003.505 - Journal URLs:
- http://www.tandfonline.com/loi/tbob20 ↗
https://www.hindawi.com/journals/abb/ ↗
http://www.atypon-link.com/WHP/loi/abib ↗
http://www.informaworld.com/smpp/title~content=t778164488~db=all ↗ - DOI:
- 10.1155/2022/3817097 ↗
- Languages:
- English
- ISSNs:
- 1176-2322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1571.911000
British Library HMNTS - ELD Digital store - Ingest File:
- 24825.xml