Dual study on the sum-of-segments method for axial length measurement: is it better?. Issue 1 (January 2023)
- Record Type:
- Journal Article
- Title:
- Dual study on the sum-of-segments method for axial length measurement: is it better?. Issue 1 (January 2023)
- Main Title:
- Dual study on the sum-of-segments method for axial length measurement: is it better?
- Authors:
- Olsen, Thomas
- Abstract:
- Abstract : The sum-of-segments axial length method was double checked by comparing preoperative and postoperative readings and by evaluating the accuracy of IOL power calculation. Abstract : Purpose: To evaluate the sum-of-segments (SOS) method for optical axial length (AL) measurements. Setting: Department of Ophthalmology, University of Aarhus, Denmark, and Private practice, Copenhagen, Denmark. Design: Retrospective observational study. Methods: 2 retrospective datasets were included. The first dataset comprised 1491 university cataract cases measured with the LENSTAR LS900 preoperatively and 1 to 4 months postoperatively. The second dataset comprised 904 lens surgery cases with refractive follow-up to study the accuracy of intraocular lens power calculation. The prediction accuracy was evaluated as the difference between the observed and the expected refraction. Results: The mean difference between the preoperative and the postoperative AL readings was −0.06 mm and −0.020 mm for the standard and the SOS AL method, respectively, however with a larger variation for the SOS AL method ( P < .01). For the second dataset, the SOS method was found to increase the accuracy of the SRK/T and the Holladay formulas. With the Olsen formula, the SOS method was found to be worse ( P < .01). The highest accuracy was found using standard AL with the Olsen formula, with a mean absolute error of 0.24 diopter (D) and 89.8% of the cases within ±0.5 D. Conclusions: The SOS method improved theAbstract : The sum-of-segments axial length method was double checked by comparing preoperative and postoperative readings and by evaluating the accuracy of IOL power calculation. Abstract : Purpose: To evaluate the sum-of-segments (SOS) method for optical axial length (AL) measurements. Setting: Department of Ophthalmology, University of Aarhus, Denmark, and Private practice, Copenhagen, Denmark. Design: Retrospective observational study. Methods: 2 retrospective datasets were included. The first dataset comprised 1491 university cataract cases measured with the LENSTAR LS900 preoperatively and 1 to 4 months postoperatively. The second dataset comprised 904 lens surgery cases with refractive follow-up to study the accuracy of intraocular lens power calculation. The prediction accuracy was evaluated as the difference between the observed and the expected refraction. Results: The mean difference between the preoperative and the postoperative AL readings was −0.06 mm and −0.020 mm for the standard and the SOS AL method, respectively, however with a larger variation for the SOS AL method ( P < .01). For the second dataset, the SOS method was found to increase the accuracy of the SRK/T and the Holladay formulas. With the Olsen formula, the SOS method was found to be worse ( P < .01). The highest accuracy was found using standard AL with the Olsen formula, with a mean absolute error of 0.24 diopter (D) and 89.8% of the cases within ±0.5 D. Conclusions: The SOS method improved the accuracy of the classical formulas probably because the optical path is a better representative of the true AL. The Olsen formula already incorporates an optical path correction, and this may be the reason for the lack of improvement with the SOS method. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 49:Issue 1(2023)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 49:Issue 1(2023)
- Issue Display:
- Volume 49, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 49
- Issue:
- 1
- Issue Sort Value:
- 2023-0049-0001-0000
- Page Start:
- 11
- Page End:
- 15
- Publication Date:
- 2023-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000001044 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24865.xml