An ultra-low-dose protocol for computed tomography-guided lung radiofrequency ablations. (1st December 2022)
- Record Type:
- Journal Article
- Title:
- An ultra-low-dose protocol for computed tomography-guided lung radiofrequency ablations. (1st December 2022)
- Main Title:
- An ultra-low-dose protocol for computed tomography-guided lung radiofrequency ablations
- Authors:
- Golin, Melissa
Izaaryene, Jean
Dassa, Michael
Piana, Gilles
Ferre, Marjorie - Abstract:
- Abstract: To evaluate the safety and efficacy of ultra-low-dose (ULD) protocol for computed tomography (CT)-guided lung radiofrequency ablation (RFA). Patients who had undergone lung RFA between November 2017 and January 2021 were consecutively and retrospectively included. Thirty patients were treated using a conventional standard protocol (SP), including helical acquisitions with mA automatic adjustment and sequential CT at 80 kVp; and 31, with a ULD protocol defined with helical acquisitions with fixed mA and sequential series at 100 kVp. These parameters were selected from those used for a diagnostic lung low-dose CT scanner. Patient characteristics, dose indicators, technical efficacy (minimal margin [MM], recurrence during follow-up), and complications (pneumothorax, alveolar haemorrhage, and haemoptysis) were recorded. We included 61 patients (median age, 65 [54–73] and 33 women), with no significant differences according to the type of protocol, except for the type of anaesthesia. Even if the number of helical acquisitions did not significantly change, all dose indicators significantly decreased by 1.5-fold–3-fold. The median dose-length-product and effective dose, with their ranges, respectively, were 465 mGy cm (315–554) and 6.5 mSv (4.4–7.8) in the SP group versus 178 mGy cm (154–267) and 2.5 mSv (2.2–3.7) in the ULD group, ( p < 001). The ULD group exhibited lower intraoperator variability and better interoperator alignment than those of the SP group. The MM wasAbstract: To evaluate the safety and efficacy of ultra-low-dose (ULD) protocol for computed tomography (CT)-guided lung radiofrequency ablation (RFA). Patients who had undergone lung RFA between November 2017 and January 2021 were consecutively and retrospectively included. Thirty patients were treated using a conventional standard protocol (SP), including helical acquisitions with mA automatic adjustment and sequential CT at 80 kVp; and 31, with a ULD protocol defined with helical acquisitions with fixed mA and sequential series at 100 kVp. These parameters were selected from those used for a diagnostic lung low-dose CT scanner. Patient characteristics, dose indicators, technical efficacy (minimal margin [MM], recurrence during follow-up), and complications (pneumothorax, alveolar haemorrhage, and haemoptysis) were recorded. We included 61 patients (median age, 65 [54–73] and 33 women), with no significant differences according to the type of protocol, except for the type of anaesthesia. Even if the number of helical acquisitions did not significantly change, all dose indicators significantly decreased by 1.5-fold–3-fold. The median dose-length-product and effective dose, with their ranges, respectively, were 465 mGy cm (315–554) and 6.5 mSv (4.4–7.8) in the SP group versus 178 mGy cm (154–267) and 2.5 mSv (2.2–3.7) in the ULD group, ( p < 001). The ULD group exhibited lower intraoperator variability and better interoperator alignment than those of the SP group. The MM was not significantly different between the two groups (4.6 mm versus 5 mm, p = 16). One local recurrence was observed in each group at 8 months in the SP and at one year in the ULD group ( p = 1). The complication rates did not differ significantly. Implementing an ULD protocol during lung RFA may provide similar efficacy, a reduction of dose indicators, and intra- and interoperator variability, without increasing complication rates, compared to those associated with an SP. … (more)
- Is Part Of:
- Journal of radiological protection. Volume 42:Number 4(2022)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 42:Number 4(2022)
- Issue Display:
- Volume 42, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2022-0042-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12-01
- Subjects:
- interventional radiology -- CT-guided -- lung radiofrequency ablation -- radiation exposure
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/acabd2 ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24843.xml