Toric intraocular lens power calculation in cataract patients with keratoconus. Issue 11 (November 2021)
- Record Type:
- Journal Article
- Title:
- Toric intraocular lens power calculation in cataract patients with keratoconus. Issue 11 (November 2021)
- Main Title:
- Toric intraocular lens power calculation in cataract patients with keratoconus
- Authors:
- Ton, Yokrat
Barrett, Graham D.
Kleinmann, Guy
Levy, Adi
Assia, Ehud I. - Abstract:
- Abstract : IOL power calculation typically results in a hyperopic outcome in patients with keratoconus. The Barrett True-K Formula for keratoconus improves refraction prediction by incorporating the posterior corneal power into calculation. Abstract : Purpose: Intraocular lens (IOL) power calculation in eyes with keratoconus typically results in hyperopic postoperative refractive error. The purpose of this study was to investigate the visual and refractive outcomes in patients with keratoconus having cataract surgery with a toric IOL and compare IOL power calculation accuracy of conventional formulas and keratoconus-specific formulas. Setting: Ein-Tal Eye Center, Tel-Aviv, Israel. Design: Retrospective case-series study. Methods: Postoperative visual acuity and manifest refraction were examined. The error in predicted refraction and IOL power calculation accuracy within a range of 0.50 to 2.00 diopters (D) were compared between different IOL calculating formulas. Results: 32 eyes with keratoconus were included. Visual acuity improved in all cases, and subjective astigmatism decreased from −2.95 ± 2.10 D to −0.95 ± 0.80 D ( P < .001). The mean absolute errors were as follows: Barrett True-K formula for keratoconus with measured or predicted posterior corneal power, 0.34 D; Barrett Universal II formula, 0.64 D; Kane formula, 0.69 D; Kane formula for keratoconus, 0.49 D; SRK/T formula, 0.56 D; Haigis formula, 0.72 D; Holladay 1 formula, 0.71 D, and Hoffer Q formula, 0.87 D.Abstract : IOL power calculation typically results in a hyperopic outcome in patients with keratoconus. The Barrett True-K Formula for keratoconus improves refraction prediction by incorporating the posterior corneal power into calculation. Abstract : Purpose: Intraocular lens (IOL) power calculation in eyes with keratoconus typically results in hyperopic postoperative refractive error. The purpose of this study was to investigate the visual and refractive outcomes in patients with keratoconus having cataract surgery with a toric IOL and compare IOL power calculation accuracy of conventional formulas and keratoconus-specific formulas. Setting: Ein-Tal Eye Center, Tel-Aviv, Israel. Design: Retrospective case-series study. Methods: Postoperative visual acuity and manifest refraction were examined. The error in predicted refraction and IOL power calculation accuracy within a range of 0.50 to 2.00 diopters (D) were compared between different IOL calculating formulas. Results: 32 eyes with keratoconus were included. Visual acuity improved in all cases, and subjective astigmatism decreased from −2.95 ± 2.10 D to −0.95 ± 0.80 D ( P < .001). The mean absolute errors were as follows: Barrett True-K formula for keratoconus with measured or predicted posterior corneal power, 0.34 D; Barrett Universal II formula, 0.64 D; Kane formula, 0.69 D; Kane formula for keratoconus, 0.49 D; SRK/T formula, 0.56 D; Haigis formula, 0.72 D; Holladay 1 formula, 0.71 D, and Hoffer Q formula, 0.87 D. Barrett True-K formula with measured posterior corneal power, SRK/T formula, and Kane formula for keratoconus resulted in a prediction error within ±0.50 D of 87.5%, 59.4%, and 53.1%, respectively. Conclusions: Cataract removal with a toric IOL significantly improves visual acuity and decreases astigmatism in keratoconic eyes with a topographic central relatively regular astigmatic component. Keratoconus-specific formulas resulted in lower mean error in predicted refraction compared with conventional calculating formulas. Using the posterior corneal power within the Barrett True-K formula for keratoconus improved IOL power prediction accuracy. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 47:Issue 11(2021)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 47:Issue 11(2021)
- Issue Display:
- Volume 47, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 47
- Issue:
- 11
- Issue Sort Value:
- 2021-0047-0011-0000
- Page Start:
- 1389
- Page End:
- 1397
- Publication Date:
- 2021-11
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000638 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24791.xml