Poststernotomy Mediastinitis and the Role of Broken Steel Wires: Retrospective Study. Issue 3 (May 2013)
- Record Type:
- Journal Article
- Title:
- Poststernotomy Mediastinitis and the Role of Broken Steel Wires: Retrospective Study. Issue 3 (May 2013)
- Main Title:
- Poststernotomy Mediastinitis and the Role of Broken Steel Wires: Retrospective Study
- Authors:
- Meeks, Michelle D.M.E.
Lozekoot, Pieter W.J.
Verstraeten, Stefan E.
Nelis, Mischa
Maessen, Jos G. - Abstract:
- Objective: Mediastinitis is a severe complication of cardiac surgery. Sternal instability is concomitantly present in most cases. Broken steel wires may cause sternal instability. In this study, the role of broken steel wires in sternal closure was evaluated in patients who developed poststernotomy mediastinitis. Methods: Preoperative, perioperative, and postoperative data of patients who underwent thoracic surgery between 1996 and 2006 were retrieved from the SUMMIT registry database. Patients needing reoperation for mediastinitis were identified. Patients' charts and chest radiographs from initial surgery to reoperation for mediastinitis were reviewed. Results: Forty-five patients developed postoperative mediastinitis needing reoperation (0.6%). Because of loss to follow-up, 31 patients were evaluated. Eight patients (25.8%) presented fractured steel wires. Most of the broken steel wires (87.5%) manifested at the cranial site of figure-of-eight configurations. In the patients without broken steel wires, mediastinitis manifested after 14 days compared with 38 days in the patients with broken wires. Time until mediastinitis was not significantly different (P = 0.229). The mean time until steel wire disruption was 14 days (range, 4–48 days). Conclusions: Broken steel wires were observed before mediastinitis became manifest. Fracturing occurred mainly at the cranial site of figure-of-eight configurations. The results of the present study emphasize that closure technique playsObjective: Mediastinitis is a severe complication of cardiac surgery. Sternal instability is concomitantly present in most cases. Broken steel wires may cause sternal instability. In this study, the role of broken steel wires in sternal closure was evaluated in patients who developed poststernotomy mediastinitis. Methods: Preoperative, perioperative, and postoperative data of patients who underwent thoracic surgery between 1996 and 2006 were retrieved from the SUMMIT registry database. Patients needing reoperation for mediastinitis were identified. Patients' charts and chest radiographs from initial surgery to reoperation for mediastinitis were reviewed. Results: Forty-five patients developed postoperative mediastinitis needing reoperation (0.6%). Because of loss to follow-up, 31 patients were evaluated. Eight patients (25.8%) presented fractured steel wires. Most of the broken steel wires (87.5%) manifested at the cranial site of figure-of-eight configurations. In the patients without broken steel wires, mediastinitis manifested after 14 days compared with 38 days in the patients with broken wires. Time until mediastinitis was not significantly different (P = 0.229). The mean time until steel wire disruption was 14 days (range, 4–48 days). Conclusions: Broken steel wires were observed before mediastinitis became manifest. Fracturing occurred mainly at the cranial site of figure-of-eight configurations. The results of the present study emphasize that closure technique plays a prominent role in the development of mediastinitis. Because mediastinitis is associated with an increased risk for early morbidity, attention should be paid to patients presenting with broken steel wires. New techniques for median sternotomy closure are needed that are less prone to mechanical fatigue than are steel wires. … (more)
- Is Part Of:
- Innovations. Volume 8:Issue 3(2013)
- Journal:
- Innovations
- Issue:
- Volume 8:Issue 3(2013)
- Issue Display:
- Volume 8, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 8
- Issue:
- 3
- Issue Sort Value:
- 2013-0008-0003-0000
- Page Start:
- 219
- Page End:
- 224
- Publication Date:
- 2013-05
- Subjects:
- Poststernotomy mediastinitis -- Steel wires -- Sternal closure
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/imi.0b013e3182a20e3c ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24802.xml