Sutureless Aortic Valve Implantation through an Upper V-Type Ministernotomy: An Innovative Approach in High-Risk Patients. Issue 1 (January 2013)
- Record Type:
- Journal Article
- Title:
- Sutureless Aortic Valve Implantation through an Upper V-Type Ministernotomy: An Innovative Approach in High-Risk Patients. Issue 1 (January 2013)
- Main Title:
- Sutureless Aortic Valve Implantation through an Upper V-Type Ministernotomy: An Innovative Approach in High-Risk Patients
- Authors:
- Concistrè, Giovanni
Miceli, Antonio
Chiaramonti, Francesca
Farneti, Pierandrea
Bevilacqua, Stefano
Varone, Egidio
Solinas, Marco
Glauber, Mattia - Abstract:
- Objective: Aortic valve replacement in minimally invasive approach has shown to improve clinical outcomes even with a prolonged cardiopulmonary bypass and aortic cross-clamp (ACC) time. Sutureless aortic valve implantation may ideally shorten operative time. We describe our initial experience with the sutureless 3f Enable (Medtronic, Inc, ATS Medical, Minneapolis, MN USA) aortic bioprosthesis implanted in minimally invasive approach in high-risk patients. Methods: Between May 2010 and May 2011, thirteen patients with severe aortic stenosis underwent aortic valve replacement with the 3f Enable bioprosthesis through an upper V-type ministernotomy interrupted at the second intercostal space. The mean ± SD age was 77 ± 3.9 years (range, 72–83 years), 10 patients were women, and the mean ± SD logistic EuroSCORE was 15% ± 13.5%. Echocardiography was performed preoperatively, at postoperative day 1, at discharge, and at follow-up. Clinical data, adverse events, and patient outcomes were recorded retrospectively. The median follow-up time was 4 months (interquartile range, 2–10 months). Results: Most of the implanted valves were 21 mm in diameter (19–25 mm). The CPB and ACC times were 100.2 ± 25.3 and 66.4 ± 18.6 minutes. At short-term follow-up, the mean ± SD pressure gradient was 14 ± 4.9 mm Hg; one patient showed trivial paravalvular leakage. No patients died during hospital stay or at follow-up. Conclusions: The 3f Enable sutureless bioprosthesis implanted in minimally invasiveObjective: Aortic valve replacement in minimally invasive approach has shown to improve clinical outcomes even with a prolonged cardiopulmonary bypass and aortic cross-clamp (ACC) time. Sutureless aortic valve implantation may ideally shorten operative time. We describe our initial experience with the sutureless 3f Enable (Medtronic, Inc, ATS Medical, Minneapolis, MN USA) aortic bioprosthesis implanted in minimally invasive approach in high-risk patients. Methods: Between May 2010 and May 2011, thirteen patients with severe aortic stenosis underwent aortic valve replacement with the 3f Enable bioprosthesis through an upper V-type ministernotomy interrupted at the second intercostal space. The mean ± SD age was 77 ± 3.9 years (range, 72–83 years), 10 patients were women, and the mean ± SD logistic EuroSCORE was 15% ± 13.5%. Echocardiography was performed preoperatively, at postoperative day 1, at discharge, and at follow-up. Clinical data, adverse events, and patient outcomes were recorded retrospectively. The median follow-up time was 4 months (interquartile range, 2–10 months). Results: Most of the implanted valves were 21 mm in diameter (19–25 mm). The CPB and ACC times were 100.2 ± 25.3 and 66.4 ± 18.6 minutes. At short-term follow-up, the mean ± SD pressure gradient was 14 ± 4.9 mm Hg; one patient showed trivial paravalvular leakage. No patients died during hospital stay or at follow-up. Conclusions: The 3f Enable sutureless bioprosthesis implanted in minimally invasive approach through an upper V-type ministernotomy is a feasible, safe, and reproducible procedure. Hemodynamic and clinical data are promising. This innovative approach might be considered as an alternative in high-risk patients. Reduction of CPB and ACC time is possible with increasing of experience and sutureless evolution of actual technology. … (more)
- Is Part Of:
- Innovations. Volume 8:Issue 1(2013)
- Journal:
- Innovations
- Issue:
- Volume 8:Issue 1(2013)
- Issue Display:
- Volume 8, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2013-0008-0001-0000
- Page Start:
- 23
- Page End:
- 28
- Publication Date:
- 2013-01
- Subjects:
- Sutureless -- Aortic valve -- Replacement -- 3f Enable -- Ministernotomy
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/imi.0b013e31828d6b03 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24772.xml