Mechanical Properties and Biological Interaction of Aortic Clamps: Are These All Minimally Invasive?. Issue 1 (January 2013)
- Record Type:
- Journal Article
- Title:
- Mechanical Properties and Biological Interaction of Aortic Clamps: Are These All Minimally Invasive?. Issue 1 (January 2013)
- Main Title:
- Mechanical Properties and Biological Interaction of Aortic Clamps: Are These All Minimally Invasive?
- Authors:
- Bianchi, Giacomo
Pucci, Angela
Matteucci, Marco
Varone, Egidio
Romano, Simone Lorenzo
Lionetti, Vincenzo
Glauber, Mattia - Abstract:
- Objective: Although specifically designed aortic clamps are mainstay of minimally invasive cardiac surgery, so far, no comparative reports about their mechanical properties and interaction with the aortic wall have been reported. In this study, the generated force in the clamps' jaws and the biological response of the aorta after clamping are evaluated. Methods: The jaw force of five commercially available clamps [Geister, Cygnet, Cardiovision (CV) 195.10, CV 195.40, and CV 195.83] was assessed by clamping a 2.2-mm compression load cell with a dedicated computer universal serial bus interface at the proximal, the middle, and the distal site from the fulcrum. Biological response of the aortic wall was assessed in five minipigs (weight, 38–40 kg) that underwent thoracic aorta clamping and leakage point test. Immunohistochemistry and morphometric analysis were carried out for each aortic segment tested. Results: Force generation pattern is peculiar of each clamp, being higher in the proximal and the middle portion and lower in the distal part. One clamp (Cygnet) exhibited homogeneous maximal force generation at all three sites. All clamps exhibited peculiar crushing artifacts. A variable degree of endothelial layer disruption occurred in all clamping tests; three clamps (CV 195.10, Cygnet, and Geister) had the lower amount of intact endothelium. The clamping force was not associated with the degree of endothelial disruption (P value was not significant). Conclusions: The choiceObjective: Although specifically designed aortic clamps are mainstay of minimally invasive cardiac surgery, so far, no comparative reports about their mechanical properties and interaction with the aortic wall have been reported. In this study, the generated force in the clamps' jaws and the biological response of the aorta after clamping are evaluated. Methods: The jaw force of five commercially available clamps [Geister, Cygnet, Cardiovision (CV) 195.10, CV 195.40, and CV 195.83] was assessed by clamping a 2.2-mm compression load cell with a dedicated computer universal serial bus interface at the proximal, the middle, and the distal site from the fulcrum. Biological response of the aortic wall was assessed in five minipigs (weight, 38–40 kg) that underwent thoracic aorta clamping and leakage point test. Immunohistochemistry and morphometric analysis were carried out for each aortic segment tested. Results: Force generation pattern is peculiar of each clamp, being higher in the proximal and the middle portion and lower in the distal part. One clamp (Cygnet) exhibited homogeneous maximal force generation at all three sites. All clamps exhibited peculiar crushing artifacts. A variable degree of endothelial layer disruption occurred in all clamping tests; three clamps (CV 195.10, Cygnet, and Geister) had the lower amount of intact endothelium. The clamping force was not associated with the degree of endothelial disruption (P value was not significant). Conclusions: The choice of a clamp that is not only minimally invasive in design but also least traumatic will help avoid complications of aortic manipulation. … (more)
- Is Part Of:
- Innovations. Volume 8:Issue 1(2013)
- Journal:
- Innovations
- Issue:
- Volume 8:Issue 1(2013)
- Issue Display:
- Volume 8, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2013-0008-0001-0000
- Page Start:
- 42
- Page End:
- 49
- Publication Date:
- 2013-01
- Subjects:
- Minimally invasive -- Valve surgery -- Aortic clamp -- Experimental -- Biological interaction
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/imi.0b013e31828d4903 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24772.xml