Image quality and diagnostic accuracy of different dosages of iodixanol in computed tomography angiography and perfusion of overweight patients with coronary artery stenosis: A feasibility study. (December 2022)
- Record Type:
- Journal Article
- Title:
- Image quality and diagnostic accuracy of different dosages of iodixanol in computed tomography angiography and perfusion of overweight patients with coronary artery stenosis: A feasibility study. (December 2022)
- Main Title:
- Image quality and diagnostic accuracy of different dosages of iodixanol in computed tomography angiography and perfusion of overweight patients with coronary artery stenosis: A feasibility study
- Authors:
- Tang, Xiaoqiang
Zhang, Yong
Wang, Tao
Ma, Yi
Shi, Haifeng
Yin, Ruohan
Zou, Ping
Cao, Jian
Pan, Changjie - Abstract:
- Highlights: The subjective definition score, signal to noise ratio, and CT value of aorta in iodixanol 320 group were higher than iodixanol 270 group. Accuracy and image quality of iodixanol 320 mg I/ml in the diagnosis of CAD with CTA-CTP was higher than using iodixanol 270 mg I/ml. The AUC, specificity, and sensitivity were 0.376, 66.67 and 80.46 respectively in iodixanol 270 group. The AUC, specificity, and sensitivity in iodixanol 320 group were 0.824, 75.00 and 89.87 respectively. Abstract: Objectives: Iodixanol contrast media with different doses using computed tomography angiography (CTA) and perfusion (CTP) to diagnose coronary artery disease (CAD) in overweight patients lacks assessment. Our study compared iodixanol 320 mg I/ml and 270 mg I/ml on image quality and accuracy of CTA combined CTP (CTA-CTP) to diagnose CAD. Methods: Overweight patients with suspected of CAD were randomized into iodixanol 270 group (received iodixanol 270 mg I/ml) and iodixanol 320 group (received iodixanol 320 mg I/ml). Based on these characteristics data, receiver operating characteristic (ROC) curve and corresponding area under the curve (AUC) were plotted to assess the sensitivity and specificity of the two administrations. Results: The subjective definition score, signal to noise ratio, and CT value of aorta in iodixanol 320 group were higher than iodixanol 270 group. In iodixanol 270 group: the image exhibited a normal state of both vessels and myocardial perfusion; and the AUC,Highlights: The subjective definition score, signal to noise ratio, and CT value of aorta in iodixanol 320 group were higher than iodixanol 270 group. Accuracy and image quality of iodixanol 320 mg I/ml in the diagnosis of CAD with CTA-CTP was higher than using iodixanol 270 mg I/ml. The AUC, specificity, and sensitivity were 0.376, 66.67 and 80.46 respectively in iodixanol 270 group. The AUC, specificity, and sensitivity in iodixanol 320 group were 0.824, 75.00 and 89.87 respectively. Abstract: Objectives: Iodixanol contrast media with different doses using computed tomography angiography (CTA) and perfusion (CTP) to diagnose coronary artery disease (CAD) in overweight patients lacks assessment. Our study compared iodixanol 320 mg I/ml and 270 mg I/ml on image quality and accuracy of CTA combined CTP (CTA-CTP) to diagnose CAD. Methods: Overweight patients with suspected of CAD were randomized into iodixanol 270 group (received iodixanol 270 mg I/ml) and iodixanol 320 group (received iodixanol 320 mg I/ml). Based on these characteristics data, receiver operating characteristic (ROC) curve and corresponding area under the curve (AUC) were plotted to assess the sensitivity and specificity of the two administrations. Results: The subjective definition score, signal to noise ratio, and CT value of aorta in iodixanol 320 group were higher than iodixanol 270 group. In iodixanol 270 group: the image exhibited a normal state of both vessels and myocardial perfusion; and the AUC, specificity, and sensitivity were 0.376, 66.67, and 80.46, respectively. In iodixanol 320 group: the image exhibited a diameter stenosis in right coronary artery and myocardial infarction of inferior wall and proximal inferior wall septum, as well as myocardial perfusion defects; and the AUC, specificity, and sensitivity in iodixanol 320 group were 0.824, 75.00, and 89.87, respectively. Conclusion: Accuracy and image quality of iodixanol 320 mg I/ml in the diagnosis of CAD with CTA-CTP was higher than using iodixanol 270 mg I/ml. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 110(2022)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 110(2022)
- Issue Display:
- Volume 110, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 110
- Issue:
- 2022
- Issue Sort Value:
- 2022-0110-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Coronary artery stenosis -- Computed tomography angiography -- Computed tomography perfusion -- Iodixanol 320 -- Iodixanol 270
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2022.103818 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24793.xml