Clinical Image Quality in Daily Practice of Breast Cancer Mammography Screening. Issue 3 (August 2014)
- Record Type:
- Journal Article
- Title:
- Clinical Image Quality in Daily Practice of Breast Cancer Mammography Screening. Issue 3 (August 2014)
- Main Title:
- Clinical Image Quality in Daily Practice of Breast Cancer Mammography Screening
- Authors:
- Guertin, Marie-Hélène
Théberge, Isabelle
Dufresne, Michel-Pierre
Zomahoun, Hervé Tchala Vignon
Major, Diane
Tremblay, Richard
Ricard, Carmen
Shumak, Rene
Wadden, Nancy
Pelletier, Éric
Brisson, Jacques - Abstract:
- Objective: To assess the quality of screening mammograms performed in daily practice in the Quebec Breast Cancer Screening Program. Subjects and Methods: Clinical image quality of a random subsample of 197 screening mammograms performed in 2004-2005 was independently evaluated by 2 radiologists based on the criteria by Canadian Association of Radiologists (CAR). When disagreement occurred for overall judgement or positioning score, the mammograms were reviewed by a third radiologist. Cohen's kappas for interrater agreement were computed. Multivariable robust Poisson regression models were used to study associations of overall quality and positioning with body mass index (BMI) and breast density. Results: The CAR criteria were not satisfied for 49.7% of the mammograms. Positioning was the quality attribute most often deficient, with 37.2% of mammograms failing positioning. Interrater agreement ranged from slight (kappa = 0.02 for compression and sharpness) to fair (kappa = 0.30 for exposure). For overall quality, women with a BMI ≥ 30 kg/m 2 had a failure proportion of 67.5% compared with 34.9% for women with a BMI<25 kg/m 2 (risk ratio 2.1 [95% confidence interval, 1.5-3.0]). For positioning, women with a BMI ≥ 30 kg/m 2 had a failure proportion of 53.8% compared with 27.9% for women with a BMI < 25 kg/m 2 (risk ratio 1.9 [95% confidence interval, 1.2-3.1]). Effects of breast density on image quality differed among radiologists. Conclusion: Despite measures to ensureObjective: To assess the quality of screening mammograms performed in daily practice in the Quebec Breast Cancer Screening Program. Subjects and Methods: Clinical image quality of a random subsample of 197 screening mammograms performed in 2004-2005 was independently evaluated by 2 radiologists based on the criteria by Canadian Association of Radiologists (CAR). When disagreement occurred for overall judgement or positioning score, the mammograms were reviewed by a third radiologist. Cohen's kappas for interrater agreement were computed. Multivariable robust Poisson regression models were used to study associations of overall quality and positioning with body mass index (BMI) and breast density. Results: The CAR criteria were not satisfied for 49.7% of the mammograms. Positioning was the quality attribute most often deficient, with 37.2% of mammograms failing positioning. Interrater agreement ranged from slight (kappa = 0.02 for compression and sharpness) to fair (kappa = 0.30 for exposure). For overall quality, women with a BMI ≥ 30 kg/m 2 had a failure proportion of 67.5% compared with 34.9% for women with a BMI<25 kg/m 2 (risk ratio 2.1 [95% confidence interval, 1.5-3.0]). For positioning, women with a BMI ≥ 30 kg/m 2 had a failure proportion of 53.8% compared with 27.9% for women with a BMI < 25 kg/m 2 (risk ratio 1.9 [95% confidence interval, 1.2-3.1]). Effects of breast density on image quality differed among radiologists. Conclusion: Despite measures to ensure high-quality imaging, including CAR accreditation, approximately half of this random sample of screening mammograms failed the CAR quality standards. It would be important to define quality targets for screening mammograms carried out in daily practice to interpret such observations. … (more)
- Is Part Of:
- Canadian Association of Radiologists journal. Volume 65:Issue 3(2014)
- Journal:
- Canadian Association of Radiologists journal
- Issue:
- Volume 65:Issue 3(2014)
- Issue Display:
- Volume 65, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 65
- Issue:
- 3
- Issue Sort Value:
- 2014-0065-0003-0000
- Page Start:
- 199
- Page End:
- 206
- Publication Date:
- 2014-08
- Subjects:
- Mammography -- Quality -- Screening -- Breast cancer
Radiology, Medical -- Periodicals
Radiology, Medical -- Canada -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/10153 ↗
http://www.carjonline.org ↗
https://journals.sagepub.com/home/caj ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/wps/find/journaldescription.cws_home/718496/description#description ↗ - DOI:
- 10.1016/j.carj.2014.02.001 ↗
- Languages:
- English
- ISSNs:
- 0846-5371
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4722.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24734.xml