Absolute thermometry using hyperpolarized 129Xe free‐induction decay and spin‐echo chemical‐shift imaging in rats. Issue 1 (19th September 2022)
- Record Type:
- Journal Article
- Title:
- Absolute thermometry using hyperpolarized 129Xe free‐induction decay and spin‐echo chemical‐shift imaging in rats. Issue 1 (19th September 2022)
- Main Title:
- Absolute thermometry using hyperpolarized 129Xe free‐induction decay and spin‐echo chemical‐shift imaging in rats
- Authors:
- Kern, Agilo L.
Gutberlet, Marcel
Rumpel, Regina
Bruesch, Inga
Hohlfeld, Jens M.
Wacker, Frank
Hensen, Bennet - Abstract:
- Abstract : Purpose: To implement and test variants of chemical shift imaging (CSI) acquiring both free induction decays (FIDs) showing all dissolved‐phase compartments and spin echoes for specifically assessing 129 $$ {}^{129} $$ Xe in lipids in order to perform precise lipid‐dissolved 129 $$ {}^{129} $$ Xe MR thermometry in a rat model of general hypothermia. Methods: Imaging was performed at 2.89 T. T 2 $$ {T}_2 $$ of 129 $$ {}^{129} $$ Xe in lipids was determined in one rat by fitting exponentials to decaying signals of global spin‐echo spectra. Four rats (conventional CSI) and six rats (turbo spectroscopic imaging) were scanned at three time points with core body temperature 37/34/37 ∘ $$ {}^{\circ } $$ C. Lorentzian functions were fit to spectra from regions of interest to determine the water‐referenced chemical shift of lipid‐dissolved 129 $$ {}^{129} $$ Xe in the abdomen. Absolute 129 $$ {}^{129} $$ Xe‐derived temperature was compared to values from a rectal probe. Results: Global T 2 $$ {T}_2 $$ of 129 $$ {}^{129} $$ Xe in lipids was determined as 251 . 3 ms ± 81 . 4 ms $$ 251.3\;\mathrm{ms}\pm 81.4\;\mathrm{ms} $$ . Friedman tests showed significant changes of chemical shift with time for both sequence variants and both FID and spin‐echo acquisitions. Mean and SD of 129 $$ {}^{129} $$ Xe and rectal probe temperature differences were found to be − 0 . 1 5 ∘ C ± 0 . 9 3 ∘ C $$ -0.1{5}^{\circ}\mathrm{C}\pm 0.9{3}^{\circ}\mathrm{C} $$ (FID) and − 0 . 3 8 ∘ C ± 0 . 6Abstract : Purpose: To implement and test variants of chemical shift imaging (CSI) acquiring both free induction decays (FIDs) showing all dissolved‐phase compartments and spin echoes for specifically assessing 129 $$ {}^{129} $$ Xe in lipids in order to perform precise lipid‐dissolved 129 $$ {}^{129} $$ Xe MR thermometry in a rat model of general hypothermia. Methods: Imaging was performed at 2.89 T. T 2 $$ {T}_2 $$ of 129 $$ {}^{129} $$ Xe in lipids was determined in one rat by fitting exponentials to decaying signals of global spin‐echo spectra. Four rats (conventional CSI) and six rats (turbo spectroscopic imaging) were scanned at three time points with core body temperature 37/34/37 ∘ $$ {}^{\circ } $$ C. Lorentzian functions were fit to spectra from regions of interest to determine the water‐referenced chemical shift of lipid‐dissolved 129 $$ {}^{129} $$ Xe in the abdomen. Absolute 129 $$ {}^{129} $$ Xe‐derived temperature was compared to values from a rectal probe. Results: Global T 2 $$ {T}_2 $$ of 129 $$ {}^{129} $$ Xe in lipids was determined as 251 . 3 ms ± 81 . 4 ms $$ 251.3\;\mathrm{ms}\pm 81.4\;\mathrm{ms} $$ . Friedman tests showed significant changes of chemical shift with time for both sequence variants and both FID and spin‐echo acquisitions. Mean and SD of 129 $$ {}^{129} $$ Xe and rectal probe temperature differences were found to be − 0 . 1 5 ∘ C ± 0 . 9 3 ∘ C $$ -0.1{5}^{\circ}\mathrm{C}\pm 0.9{3}^{\circ}\mathrm{C} $$ (FID) and − 0 . 3 8 ∘ C ± 0 . 6 4 ∘ C $$ -0.3{8}^{\circ}\mathrm{C}\pm 0.6{4}^{\circ}\mathrm{C} $$ (spin echo) for conventional CSI as well as 0 . 0 3 ∘ C ± 0 . 7 7 ∘ C $$ 0.0{3}^{\circ}\mathrm{C}\pm 0.7{7}^{\circ}\mathrm{C} $$ (FID) and − 0 . 0 6 ∘ C ± 0 . 7 6 ∘ C $$ -0.0{6}^{\circ}\mathrm{C}\pm 0.7{6}^{\circ}\mathrm{C} $$ (spin echo) for turbo spectroscopic imaging. Conclusion: 129 $$ {}^{129} $$ Xe MRI using conventional CSI and turbo spectroscopic imaging of lipid‐dissolved 129 $$ {}^{129} $$ Xe enables precise temperature measurements in the rat's abdomen using both FID and spin‐echo acquisitions with acquisition of spin echoes enabling most precise temperature measurements. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 1(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 1(2023)
- Issue Display:
- Volume 89, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 1
- Issue Sort Value:
- 2023-0089-0001-0000
- Page Start:
- 54
- Page End:
- 63
- Publication Date:
- 2022-09-19
- Subjects:
- 129$$ {}^{129} $$Xe -- chemical‐shift imaging -- lipid -- MRI thermometry -- rat -- spin echo
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29455 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24737.xml