Dynamic response and emergency measures under failure conditions of sCO2 Brayton cycle. Issue 12 (5th September 2022)
- Record Type:
- Journal Article
- Title:
- Dynamic response and emergency measures under failure conditions of sCO2 Brayton cycle. Issue 12 (5th September 2022)
- Main Title:
- Dynamic response and emergency measures under failure conditions of sCO2 Brayton cycle
- Authors:
- Wang, Rui
Li, Xinyu
Qin, Zheng
Wang, Lintao
Lin, Zhimin
Wang, Xuan
Tian, Hua
Shu, Gequn - Abstract:
- Abstract: The sCO2 Brayton cycle has gained interest because of its flexibility and ability to provide higher thermomechanical conversion efficiency. Studies on failure conditions and corresponding emergency measures are of great significance to ensure the safety of the system, while there are limited studies related to the sCO2 Brayton cycle because the test circuit has not been applied in practice at present. In this study, we have developed a dynamic model of the CO2 Brayton cycle, and carefully validated its components against experimental data. Preliminary safety assessment and dynamic response under loss of cooling water (LOCW), loss of heat source (LOHS), and pipeline leakage have been analyzed. Emergency strategies are proposed to maintain the safe operation under failure conditions. The primary objective of this study is to reveal the dynamic performance and emergency measures under failure conditions of the sCO2 Brayton cycle. The results demonstrate that the system net power decreases at rates close to 10%/s and less than 0.1%/s under LOCW and LOHS, respectively. The system responds more dramatically under LOCW compared with LOHS. The system needs emergency measures under LOCW, while it has sufficient time to realize a normal slow shutdown under LOHS. The leakage rate is at least five times higher in the high‐pressure pipeline compared with the low‐pressure pipeline for the same area of the leakage hole. Under pipeline leakage, the heat source should be cut‐offAbstract: The sCO2 Brayton cycle has gained interest because of its flexibility and ability to provide higher thermomechanical conversion efficiency. Studies on failure conditions and corresponding emergency measures are of great significance to ensure the safety of the system, while there are limited studies related to the sCO2 Brayton cycle because the test circuit has not been applied in practice at present. In this study, we have developed a dynamic model of the CO2 Brayton cycle, and carefully validated its components against experimental data. Preliminary safety assessment and dynamic response under loss of cooling water (LOCW), loss of heat source (LOHS), and pipeline leakage have been analyzed. Emergency strategies are proposed to maintain the safe operation under failure conditions. The primary objective of this study is to reveal the dynamic performance and emergency measures under failure conditions of the sCO2 Brayton cycle. The results demonstrate that the system net power decreases at rates close to 10%/s and less than 0.1%/s under LOCW and LOHS, respectively. The system responds more dramatically under LOCW compared with LOHS. The system needs emergency measures under LOCW, while it has sufficient time to realize a normal slow shutdown under LOHS. The leakage rate is at least five times higher in the high‐pressure pipeline compared with the low‐pressure pipeline for the same area of the leakage hole. Under pipeline leakage, the heat source should be cut‐off slowly, and the rotation speeds of the main compressor and recompressor should be reduced simultaneously to protect the system. Abstract : Preliminary safety assessment and dynamic response under loss of cooling water, loss of heat source, and pipeline leakage have been analyzed. Emergency strategies are proposed to maintain the safe operation under failure conditions. The primary objective of this study is to reveal the dynamic performance and emergency measures under failure conditions of the sCO2 Brayton cycle. … (more)
- Is Part Of:
- Energy science & engineering. Volume 10:Issue 12(2022)
- Journal:
- Energy science & engineering
- Issue:
- Volume 10:Issue 12(2022)
- Issue Display:
- Volume 10, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 10
- Issue:
- 12
- Issue Sort Value:
- 2022-0010-0012-0000
- Page Start:
- 4726
- Page End:
- 4746
- Publication Date:
- 2022-09-05
- Subjects:
- emergency measures -- failure conditions -- pipeline leakage -- sCO2 Brayton cycle
Energy industries -- Periodicals
Energy development -- Periodicals
Power resources -- Periodicals
621.042 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2050-0505 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ese3.1300 ↗
- Languages:
- English
- ISSNs:
- 2050-0505
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24716.xml