Optimal damper placement in hybrid control system of multiple isolation and building connection. (2017)
- Record Type:
- Journal Article
- Title:
- Optimal damper placement in hybrid control system of multiple isolation and building connection. (2017)
- Main Title:
- Optimal damper placement in hybrid control system of multiple isolation and building connection
- Authors:
- Tamura, Goki
Taniguchi, Masaki
Fujita, Kohei
Tsuji, Masaaki
Takewaki, Izuru - Abstract:
- An algorithm for optimal damper placement is proposed in a hybrid control system of multiple isolation and building connection. Such innovative hybrid control building system has been proposed recently. It is a great concern whether the seismic displacement response at the base-isolation layer of the existing base-isolated buildings may be amplified under long-period and long-duration ground motions. In order to enhance the robustness on the seismic performance of those base-isolated buildings, a novel hybrid system of multiple isolation and building-connection has been proposed and compared with other structural systems such as an independent multiple isolation system, a hybrid system of base-isolation and building-connection in the previous paper. It has been made clear that such hybrid control system possesses a remarkable performance for various types of earthquake ground motions. After the investigation of the effective location of the middle isolation story, a sensitivity-based optimisation algorithm is proposed for optimal connection damper placement in such hybrid control system.
- Is Part Of:
- International journal of earthquake and impact engineering. Volume 2:Number 1(2017)
- Journal:
- International journal of earthquake and impact engineering
- Issue:
- Volume 2:Number 1(2017)
- Issue Display:
- Volume 1000001, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 1000001
- Issue:
- 1
- Issue Sort Value:
- 2017-1000001-0001-0000
- Page Start:
- 67
- Page End:
- 87
- Publication Date:
- 2017
- Subjects:
- multiple isolation -- building-connection control -- hybrid passive control system -- robustness -- redundancy -- optimal damper location
- Journal URLs:
- http://www.inderscience.com/jhome.php?jcode=IJEIE ↗
http://www.inderscience.com/ ↗ - Languages:
- English
- ISSNs:
- 2397-9372
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24723.xml