Investigation of the performance of cross-linked poly(acrylic acid) and poly(methacrylic acid) as efficient adsorbents in SPE columns for simultaneous preconcentration of tricyclic antidepressants in water samples. Issue 48 (6th December 2022)
- Record Type:
- Journal Article
- Title:
- Investigation of the performance of cross-linked poly(acrylic acid) and poly(methacrylic acid) as efficient adsorbents in SPE columns for simultaneous preconcentration of tricyclic antidepressants in water samples. Issue 48 (6th December 2022)
- Main Title:
- Investigation of the performance of cross-linked poly(acrylic acid) and poly(methacrylic acid) as efficient adsorbents in SPE columns for simultaneous preconcentration of tricyclic antidepressants in water samples
- Authors:
- Teixeira Tarley, César Ricardo
Gorla, Felipe Augusto
Midori de Oliveira, Fernanda
Nascentes, Clésia Cristina
Ferreira, Milena do Prado
Ferreira da Costa, Marcello
Segatelli, Mariana Gava - Abstract:
- Abstract : An SPE-based procedure for simultaneous preconcentration of tricyclic antidepressants was developed. Two organic polymers were used as adsorbent materials which showed high sensitivity. Abstract : A solid phase extraction-based (SPE) procedure for simultaneous preconcentration of five tricyclic antidepressants (TCAs), amitriptyline hydrochloride (AMT), nortriptyline hydrochloride (NOR), doxepin hydrochloride (DOX), imipramine hydrochloride (IMI), and clomipramine hydrochloride (CLO) from water samples with determination by HPLC-DAD is proposed. Polymers were characterized by FT-IR, SEM, and thermogravimetric analysis. SPE-based methods were carried out by the preconcentration of 320.0 mL of TCAs at pH 7.0 (buffered with 0.01 mol L −1 phosphate buffer) through 70.0 mg of adsorbent packed into a SPE cartridge, followed by elution with 1.0 mL of ACN : MeOH : acetic acid solution (45 : 45 : 10% v/v). Higher preconcentration factors were obtained ranging from 117.9 to 372.2 and 207.1 to 396.1 by using poly(MAA- co -EGDMA) and poly(AA- co -EGDMA), respectively, yielding lower limits of detection (0.03 to 0.12 μg L −1 ) and (0.03 to 0.15 μg L −1 ). These outcomes show satisfactory detectability of SPE-based methods, with slightly better performance using poly(MAA- co -EGDMA). On the other hand, poly(AA- co -EGDMA) was able to preconcentrate TCAs in the presence of humic acid (7.0 mg L −1 ) without interference. The precision of methods assessed as RSD (%) was veryAbstract : An SPE-based procedure for simultaneous preconcentration of tricyclic antidepressants was developed. Two organic polymers were used as adsorbent materials which showed high sensitivity. Abstract : A solid phase extraction-based (SPE) procedure for simultaneous preconcentration of five tricyclic antidepressants (TCAs), amitriptyline hydrochloride (AMT), nortriptyline hydrochloride (NOR), doxepin hydrochloride (DOX), imipramine hydrochloride (IMI), and clomipramine hydrochloride (CLO) from water samples with determination by HPLC-DAD is proposed. Polymers were characterized by FT-IR, SEM, and thermogravimetric analysis. SPE-based methods were carried out by the preconcentration of 320.0 mL of TCAs at pH 7.0 (buffered with 0.01 mol L −1 phosphate buffer) through 70.0 mg of adsorbent packed into a SPE cartridge, followed by elution with 1.0 mL of ACN : MeOH : acetic acid solution (45 : 45 : 10% v/v). Higher preconcentration factors were obtained ranging from 117.9 to 372.2 and 207.1 to 396.1 by using poly(MAA- co -EGDMA) and poly(AA- co -EGDMA), respectively, yielding lower limits of detection (0.03 to 0.12 μg L −1 ) and (0.03 to 0.15 μg L −1 ). These outcomes show satisfactory detectability of SPE-based methods, with slightly better performance using poly(MAA- co -EGDMA). On the other hand, poly(AA- co -EGDMA) was able to preconcentrate TCAs in the presence of humic acid (7.0 mg L −1 ) without interference. The precision of methods assessed as RSD (%) was very similar, ranging from 1.7% to 16.3% for poly(MAA- co -EGDMA) and 1.7% to 13.4% for poly(AA- co -EGDMA). SPE cartridges packed with the polymers showed high reusability (52 cycles of preconcentration and elution) without losing adsorption efficiency. The methods were applied to determine TCAs in tap, lake, and stream water samples and the accuracy was attested by addition and recovery tests (86.7–116.0%), with determined nortriptyline ranging from 0.48 to 0.52 μg L −1 in lake water samples. … (more)
- Is Part Of:
- Analytical methods. Volume 14:Issue 48(2022)
- Journal:
- Analytical methods
- Issue:
- Volume 14:Issue 48(2022)
- Issue Display:
- Volume 14, Issue 48 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 48
- Issue Sort Value:
- 2022-0014-0048-0000
- Page Start:
- 5100
- Page End:
- 5109
- Publication Date:
- 2022-12-06
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2ay01520j ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24725.xml