A Steadier Hand: The First Human Clinical Trial of a Single-Use Robotic-Assisted Surgical Device for Cochlear Implant Electrode Array Insertion. Issue 1 (14th January 2023)
- Record Type:
- Journal Article
- Title:
- A Steadier Hand: The First Human Clinical Trial of a Single-Use Robotic-Assisted Surgical Device for Cochlear Implant Electrode Array Insertion. Issue 1 (14th January 2023)
- Main Title:
- A Steadier Hand: The First Human Clinical Trial of a Single-Use Robotic-Assisted Surgical Device for Cochlear Implant Electrode Array Insertion
- Authors:
- Gantz, Jay A.
Gantz, Bruce J.
Kaufmann, Christopher R.
Henslee, Allan M.
Dunn, Camille C.
Hua, Xiaoyang
Hansen, Marlan R. - Abstract:
- Abstract : Objective: To evaluate the safety and utility of an investigational robotic-assisted cochlear implant insertion system. Study Design: Prospective, single-arm, open-label study under abbreviated Investigational Device Exemption requirements. Setting: All procedures were performed, and all data were collected, at a single tertiary referral center. Patients: Twenty-one postlingually deafened adult subjects that met Food and Drug Administration indication criteria for cochlear implantation. Intervention: All patients underwent standard-of-care surgery for unilateral cochlear implantation with the addition of a single-use robotic-assisted insertion device during cochlear electrode insertion. Main Outcome Measures: Successful insertion of cochlear implant electrode array, electrode array insertion time, postoperative implant function. Results: Successful robotic-assisted insertion of lateral wall cochlear implant electrode arrays was achieved in 20 (95.2%) of 21 patients. One insertion was unable to be achieved by either robotic-assisted or manual insertion methods, and the patient was retrospectively found to have a preexisting cochlear fracture. Mean intracochlear electrode array insertion time was 3 minutes 15 seconds. All implants with successful robotic-assisted electrode array insertion (n = 20) had normal impedance and neural response telemetry measures for up to 6 months after surgery. Conclusions: Here we report the first human trial of a single-useAbstract : Objective: To evaluate the safety and utility of an investigational robotic-assisted cochlear implant insertion system. Study Design: Prospective, single-arm, open-label study under abbreviated Investigational Device Exemption requirements. Setting: All procedures were performed, and all data were collected, at a single tertiary referral center. Patients: Twenty-one postlingually deafened adult subjects that met Food and Drug Administration indication criteria for cochlear implantation. Intervention: All patients underwent standard-of-care surgery for unilateral cochlear implantation with the addition of a single-use robotic-assisted insertion device during cochlear electrode insertion. Main Outcome Measures: Successful insertion of cochlear implant electrode array, electrode array insertion time, postoperative implant function. Results: Successful robotic-assisted insertion of lateral wall cochlear implant electrode arrays was achieved in 20 (95.2%) of 21 patients. One insertion was unable to be achieved by either robotic-assisted or manual insertion methods, and the patient was retrospectively found to have a preexisting cochlear fracture. Mean intracochlear electrode array insertion time was 3 minutes 15 seconds. All implants with successful robotic-assisted electrode array insertion (n = 20) had normal impedance and neural response telemetry measures for up to 6 months after surgery. Conclusions: Here we report the first human trial of a single-use robotic-assisted surgical device for cochlear implant electrode array insertion. This device successfully and safely inserted lateral wall cochlear implant electrode arrays from the three device manufacturers with devices approved but he Food and Drug Administration. … (more)
- Is Part Of:
- Otology & neurotology. Volume 44:Issue 1(2023)
- Journal:
- Otology & neurotology
- Issue:
- Volume 44:Issue 1(2023)
- Issue Display:
- Volume 44, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2023-0044-0001-0000
- Page Start:
- 34
- Page End:
- 39
- Publication Date:
- 2023-01-14
- Subjects:
- Cochlear implant -- Cochlear implant trauma -- Robotic electrode array insertion -- Robotic surgery -- Robotic-assisted cochlear implant device -- Robotic-assisted electrode array insertion -- Robotic-assisted surgery
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000003749 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24682.xml