Machine characterization and central axis depth dose data of a superficial x-ray radiotherapy unit. (1st January 2023)
- Record Type:
- Journal Article
- Title:
- Machine characterization and central axis depth dose data of a superficial x-ray radiotherapy unit. (1st January 2023)
- Main Title:
- Machine characterization and central axis depth dose data of a superficial x-ray radiotherapy unit
- Authors:
- Xiong, Zhenyu
Zhong, Yuncheng
Banks, Thomas I.
Reynolds, Robert
Chiu, Tsuicheng
Tan, Jun
Zhang, You
Parsons, David
Yan, Yulong
Godley, Andrew
Stojadinovic, Strahinja - Abstract:
- Abstract: Objectives . The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods . Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results . The x-ray unit's mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (<100 kVp) and medium-energy (≥100 kVp) superficial beams the average agreement was within [−3.6, +0.4]% and [−3.7, +1.4]% range, respectively. For the high-energy superficial (low-energy orthovoltage) x-rays at 150 kVp, the average difference for the largest 20 × 20 cm 2 collimator was (−0.7 ± 1.0)%, Conclusions . This study presents machine characterization data collected for clinical use of aAbstract: Objectives . The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods . Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results . The x-ray unit's mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (<100 kVp) and medium-energy (≥100 kVp) superficial beams the average agreement was within [−3.6, +0.4]% and [−3.7, +1.4]% range, respectively. For the high-energy superficial (low-energy orthovoltage) x-rays at 150 kVp, the average difference for the largest 20 × 20 cm 2 collimator was (−0.7 ± 1.0)%, Conclusions . This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements, Advances in knowledge . This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted. … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 9:Number 1(2023)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 9:Number 1(2023)
- Issue Display:
- Volume 9, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 9
- Issue:
- 1
- Issue Sort Value:
- 2023-0009-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01-01
- Subjects:
- superficial radiotherapy -- kV percent depth dose -- commissioning of superficial radiotherapy unit
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/aca611 ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24672.xml