Ultrasound measures of muscle thickness and subcutaneous tissue from the hip abductors: Inter- and intra-rater reliability. (December 2022)
- Record Type:
- Journal Article
- Title:
- Ultrasound measures of muscle thickness and subcutaneous tissue from the hip abductors: Inter- and intra-rater reliability. (December 2022)
- Main Title:
- Ultrasound measures of muscle thickness and subcutaneous tissue from the hip abductors: Inter- and intra-rater reliability
- Authors:
- Lanza, Marcel Bahia
Rock, Kelly
Marchese, Victoria
Gray, Vicki L.
Addison, Odessa - Abstract:
- Abstract: Background: Ultrasound imaging is important in many fields such as medicine, sports, and health sciences to assess parts of muscle structure (e.g., muscle thickness [MT]) or composition (subcutaneous tissue [SubT ]). Objective: The aim of the present study was to investigate the intra- and inter-rater reliability of MT and SubT measurements of the hip abductor muscles gluteus medius (GM) and tensor fascia latae (TFL). Design: Cross-sectional study. Method: Twenty young adults participated in the study. Intra-rater reliability was established by measuring the same two images twice by the same rater, while inter-rater reliability was assessed between two raters by measuring the same two images for each muscle. For both intra- and inter-rater reliability, the reliability of the TFL and GM outcomes (MT- SubT ) were determined by the intraclass correlation coefficient (ICC), coefficient of variation (CV), standard error of the measurement (SEM), and Bland-Altman plots. Results: For intra-rater reliability, variables of both muscles showed an excellent ICC (≥0.90), lower CV and SEM, and bias near zero. Inter-rater reliability also showed an excellent ICC for both variables and muscles (≥0.81) with lower CV, SEM, and bias. Conclusion: Therefore, these results provide strong evidence of a reliable measure of MT and SubT from GM and TFL. The present study provides health care professionals and researchers increased confidence in using 2D ultrasound to assess the hipAbstract: Background: Ultrasound imaging is important in many fields such as medicine, sports, and health sciences to assess parts of muscle structure (e.g., muscle thickness [MT]) or composition (subcutaneous tissue [SubT ]). Objective: The aim of the present study was to investigate the intra- and inter-rater reliability of MT and SubT measurements of the hip abductor muscles gluteus medius (GM) and tensor fascia latae (TFL). Design: Cross-sectional study. Method: Twenty young adults participated in the study. Intra-rater reliability was established by measuring the same two images twice by the same rater, while inter-rater reliability was assessed between two raters by measuring the same two images for each muscle. For both intra- and inter-rater reliability, the reliability of the TFL and GM outcomes (MT- SubT ) were determined by the intraclass correlation coefficient (ICC), coefficient of variation (CV), standard error of the measurement (SEM), and Bland-Altman plots. Results: For intra-rater reliability, variables of both muscles showed an excellent ICC (≥0.90), lower CV and SEM, and bias near zero. Inter-rater reliability also showed an excellent ICC for both variables and muscles (≥0.81) with lower CV, SEM, and bias. Conclusion: Therefore, these results provide strong evidence of a reliable measure of MT and SubT from GM and TFL. The present study provides health care professionals and researchers increased confidence in using 2D ultrasound to assess the hip abductors muscles reliably. Highlights: To measure hip abductors muscle structure ultrasound images are often used . Hip abductor's intra-rater reliability of muscle structure was excellent . Similarly, hip abductor's inter-rater reliability of muscle structure was excellent . … (more)
- Is Part Of:
- Musculoskeletal science and practice. Volume 62(2022)
- Journal:
- Musculoskeletal science and practice
- Issue:
- Volume 62(2022)
- Issue Display:
- Volume 62, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 62
- Issue:
- 2022
- Issue Sort Value:
- 2022-0062-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Ultrasound imaging -- Hip abductor muscles -- Gluteus medius -- Tensor fascia latae -- Muscle structure
Manipulation (Therapeutics) -- Periodicals
Physical therapy -- Periodicals
Neuromuscular diseases -- Treatment -- Periodicals
Musculoskeletal system -- Diseases -- Periodicals
Manipulation (Therapeutics)
Neuromuscular diseases -- Treatment
Physical therapy
Manipulation, Orthopedic
Musculoskeletal Diseases -- therapy
Neuromuscular Diseases -- therapy
Physical Therapy Modalities
Electronic journals
Periodicals
615.82 - Journal URLs:
- https://www.clinicalkey.com/#!/browse/journal/24687812/latest ↗
https://www.journals.elsevier.com/musculoskeletal-science-and-practice ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.msksp.2022.102612 ↗
- Languages:
- English
- ISSNs:
- 2468-8630
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5986.535400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24673.xml