Ventricular arrhythmias in Kearns–Sayre syndrome: A cohort study using the National Inpatient Sample database 2016–2019. Issue 12 (27th October 2022)
- Record Type:
- Journal Article
- Title:
- Ventricular arrhythmias in Kearns–Sayre syndrome: A cohort study using the National Inpatient Sample database 2016–2019. Issue 12 (27th October 2022)
- Main Title:
- Ventricular arrhythmias in Kearns–Sayre syndrome: A cohort study using the National Inpatient Sample database 2016–2019
- Authors:
- Wiseman, Kyle
Gor, Dhairya
Udongwo, Ndausung
Alshami, Abbas
Upadhaya, Vandan
Daniels, Steven J.
Chung, Wendy K.
Koo, Charles H. - Abstract:
- Abstract: BACKGROUND: Degeneration of the cardiac conduction system resulting in complete heart block (CHB), ventricular arrhythmias (VA), and sudden cardiac death (SCD) is recognized in patients with Kearns–Sayre syndrome (KSS) and is potentially preventable with permanent pacemaker (PPM) implantation. However, other mechanisms for SCD have been proposed, and the efficacy of implanting a defibrillator instead of PPM remains to be investigated. METHODS: We utilized the National Inpatient Sample (NIS) database 2016–2019 to investigate the risk of VA or dysrhythmic cardiac arrest (dCA) in KSS patients. We compared the outcomes of KSS to myotonic dystrophy (MD), a more common genetic disorder with similar clinical cardiac features and course. RESULTS: We identified 640 admissions for KSS. VA or dCA were lower in admissions for KSS than MD patients (2.3% vs. 4.5%, p = .009). Device implantation differed between study groups. Approximately, 70% of cases with KSS and conduction abnormalities had pacemaker (± defibrillator) on hospital discharge, compared to 35% in MD. Conduction abnormalities were associated with higher rates of VA or dCA in both study groups. None of the admissions for KSS patients who developed VA or dCA had a pacemaker, and all of them had conduction abnormalities. One‐third of admissions for MD patients who developed VA or dCA had a device already implanted prior to the event. CONCLUSION: Despite its effectiveness in preventing VA, PPM remains underutilizedAbstract: BACKGROUND: Degeneration of the cardiac conduction system resulting in complete heart block (CHB), ventricular arrhythmias (VA), and sudden cardiac death (SCD) is recognized in patients with Kearns–Sayre syndrome (KSS) and is potentially preventable with permanent pacemaker (PPM) implantation. However, other mechanisms for SCD have been proposed, and the efficacy of implanting a defibrillator instead of PPM remains to be investigated. METHODS: We utilized the National Inpatient Sample (NIS) database 2016–2019 to investigate the risk of VA or dysrhythmic cardiac arrest (dCA) in KSS patients. We compared the outcomes of KSS to myotonic dystrophy (MD), a more common genetic disorder with similar clinical cardiac features and course. RESULTS: We identified 640 admissions for KSS. VA or dCA were lower in admissions for KSS than MD patients (2.3% vs. 4.5%, p = .009). Device implantation differed between study groups. Approximately, 70% of cases with KSS and conduction abnormalities had pacemaker (± defibrillator) on hospital discharge, compared to 35% in MD. Conduction abnormalities were associated with higher rates of VA or dCA in both study groups. None of the admissions for KSS patients who developed VA or dCA had a pacemaker, and all of them had conduction abnormalities. One‐third of admissions for MD patients who developed VA or dCA had a device already implanted prior to the event. CONCLUSION: Despite its effectiveness in preventing VA, PPM remains underutilized in patients with KSS or MD who have conduction abnormalities. PPM alone do not fully prevent VA in MD patients; therefore, addition of defibrillator capacity might be necessary. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 45:Issue 12(2022)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 45:Issue 12(2022)
- Issue Display:
- Volume 45, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 45
- Issue:
- 12
- Issue Sort Value:
- 2022-0045-0012-0000
- Page Start:
- 1357
- Page End:
- 1363
- Publication Date:
- 2022-10-27
- Subjects:
- conduction defects -- implantable cardioverter‐defibrillator -- Kearns–Sayre syndrome -- myotonic dystrophy -- pacemaker -- ventricular tachycardia
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.14607 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: