Accuracy of the ActivPAL and Fitbit Charge 2 in measuring step count in Cystic Fibrosis. (18th November 2022)
- Record Type:
- Journal Article
- Title:
- Accuracy of the ActivPAL and Fitbit Charge 2 in measuring step count in Cystic Fibrosis. (18th November 2022)
- Main Title:
- Accuracy of the ActivPAL and Fitbit Charge 2 in measuring step count in Cystic Fibrosis
- Authors:
- Curran, Maire
Tierney, Audrey
Collins, Louise
Kennedy, Lauren
McDonnell, Ciara
Sheikhi, Ali
Walsh, Cathal
Casserly, Brian
Cahalan, Roisin - Abstract:
- ABSTRACT: Background: Physical activity (PA) is important in Cystic Fibrosis (CF) management. Fitness wearables are becoming increasingly popular as measurement tools of PA; however, the accuracy of these devices should first be evaluated. Objective: The purpose of this study was to assess the accuracy of the ActivPAL and Fitbit Charge 2 as a measure of step count in Cystic Fibrosis. Methods: Twenty-one participants were recruited from an adult CF Center in Ireland for a single session of testing. Participants walked for 5 min at five pre-determined speeds in a controlled testing environment (2, 2.5, 3, 3.5 and 4 miles per hour on a treadmill) and at three self-selected speeds in a corridor (slow, medium, and fast). They concurrently wore an accelerometer (ActivPAL) and fitness wearable (Fitbit Charge 2), and both were compared to visual observations. Step count is the outcome being assessed. Results: The ActivPAL under-estimated step count by 0.63% across treadmill speeds and 1.1% across self-selected walking speeds. The Fitbit Charge 2 underestimated the step count by 2.97% across treadmill speeds and by 6.3% across self-selected walking speeds. Very strong correlations were found between the ActivPAL and visual observations (r: 0.93 to 0.99), while the Fitbit Charge 2 ranged from weak to very strong correlations when compared to visual observations (r: 0.34 to 0.84). Conclusion: The ActivPAL and Fitbit Charge 2 demonstrated acceptable validity for step count measurementABSTRACT: Background: Physical activity (PA) is important in Cystic Fibrosis (CF) management. Fitness wearables are becoming increasingly popular as measurement tools of PA; however, the accuracy of these devices should first be evaluated. Objective: The purpose of this study was to assess the accuracy of the ActivPAL and Fitbit Charge 2 as a measure of step count in Cystic Fibrosis. Methods: Twenty-one participants were recruited from an adult CF Center in Ireland for a single session of testing. Participants walked for 5 min at five pre-determined speeds in a controlled testing environment (2, 2.5, 3, 3.5 and 4 miles per hour on a treadmill) and at three self-selected speeds in a corridor (slow, medium, and fast). They concurrently wore an accelerometer (ActivPAL) and fitness wearable (Fitbit Charge 2), and both were compared to visual observations. Step count is the outcome being assessed. Results: The ActivPAL under-estimated step count by 0.63% across treadmill speeds and 1.1% across self-selected walking speeds. The Fitbit Charge 2 underestimated the step count by 2.97% across treadmill speeds and by 6.3% across self-selected walking speeds. Very strong correlations were found between the ActivPAL and visual observations (r: 0.93 to 0.99), while the Fitbit Charge 2 ranged from weak to very strong correlations when compared to visual observations (r: 0.34 to 0.84). Conclusion: The ActivPAL and Fitbit Charge 2 demonstrated acceptable validity for step count measurement in CF. These devices can be used for tracking PA during interventions in people with CF. … (more)
- Is Part Of:
- Physiotherapy theory and practice. Volume 38:Number 13(2022)
- Journal:
- Physiotherapy theory and practice
- Issue:
- Volume 38:Number 13(2022)
- Issue Display:
- Volume 38, Issue 13 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 13
- Issue Sort Value:
- 2022-0038-0013-0000
- Page Start:
- 2962
- Page End:
- 2972
- Publication Date:
- 2022-11-18
- Subjects:
- Cystic fibrosis -- step count -- physical activity -- validation -- accuracy
Physical therapy -- Periodicals
615.82 - Journal URLs:
- http://informahealthcare.com/loi/ptp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/09593985.2021.1962463 ↗
- Languages:
- English
- ISSNs:
- 0959-3985
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6489.140000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24667.xml