Comparison of Clinical and Radiological Outcomes between Calibratable Patient-Specific Instrumentation and Conventional Operation for Medial Open-Wedge High Tibial Osteotomy: A Randomized Controlled Trial. (23rd November 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of Clinical and Radiological Outcomes between Calibratable Patient-Specific Instrumentation and Conventional Operation for Medial Open-Wedge High Tibial Osteotomy: A Randomized Controlled Trial. (23rd November 2022)
- Main Title:
- Comparison of Clinical and Radiological Outcomes between Calibratable Patient-Specific Instrumentation and Conventional Operation for Medial Open-Wedge High Tibial Osteotomy: A Randomized Controlled Trial
- Authors:
- Gao, Fawei
Yang, Xucheng
Wang, Chenggong
Su, Shilong
Qi, Jun
Li, Zhigang
Chen, Juehao
Zhong, Da - Other Names:
- Bini Fabiano Academic Editor.
- Abstract:
- Abstract : Background . High tibial osteotomy (HTO) is an effective surgery in treating medial compartment knee osteoarthritis (KOA) combined with varus deformity. An accurate orthopaedy is the key and challenge to the success of HTO. Therefore, we designed a calibratable patient-specific instrumentation (PSI) to assist surgery and evaluated its accuracy and clinical outcomes by comparing with conventional operation (CO). Materials and Methods . 37 patients (39 knees) with medial compartment KOA were randomly divided into the PSI and CO groups and underwent medial open-wedge high tibial osteotomy (MOWHTO) from September 2020 to May 2021. The postoperative radiological outcomes were compared with the preoperative measurements or target values to evaluate the accuracy of correction in the two groups. The American Knee Society Score (AKSS), complication rate, number of intraoperative radiation exposures, blood loss volume, and operative duration were analysed to evaluate the clinical outcomes in the two groups. Results . The designed target values were better achieved in the PSI group than in the CO group. The mean absolute difference between the postoperative measurements and preoperative targets was significantly lower in the PSI group than in the CO group (weight-bearing line (WBL) ratio, 1.97 ± 1.83 % vs.5.42 ± 4.41 %, P = 0.002 ; hip-knee-ankle (HKA) angle, 1.12 ± 0.86 ° vs. 2.27 ± 1.97 °, P = 0.018 ). The operative duration was significantly shorter (P = 0.014 ), and theAbstract : Background . High tibial osteotomy (HTO) is an effective surgery in treating medial compartment knee osteoarthritis (KOA) combined with varus deformity. An accurate orthopaedy is the key and challenge to the success of HTO. Therefore, we designed a calibratable patient-specific instrumentation (PSI) to assist surgery and evaluated its accuracy and clinical outcomes by comparing with conventional operation (CO). Materials and Methods . 37 patients (39 knees) with medial compartment KOA were randomly divided into the PSI and CO groups and underwent medial open-wedge high tibial osteotomy (MOWHTO) from September 2020 to May 2021. The postoperative radiological outcomes were compared with the preoperative measurements or target values to evaluate the accuracy of correction in the two groups. The American Knee Society Score (AKSS), complication rate, number of intraoperative radiation exposures, blood loss volume, and operative duration were analysed to evaluate the clinical outcomes in the two groups. Results . The designed target values were better achieved in the PSI group than in the CO group. The mean absolute difference between the postoperative measurements and preoperative targets was significantly lower in the PSI group than in the CO group (weight-bearing line (WBL) ratio, 1.97 ± 1.83 % vs.5.42 ± 4.41 %, P = 0.002 ; hip-knee-ankle (HKA) angle, 1.12 ± 0.86 ° vs. 2.27 ± 1.97 °, P = 0.018 ). The operative duration was significantly shorter (P = 0.014 ), and the number of radiation exposures (P < 0.001 ) and volume of intraoperative blood loss (P = 0.003 ) were significantly lower in the PSI group than in the CO group. The clinical AKSS score at 3 and 6 months postoperatively and the functional AKSS score at 3 months postoperatively were significantly higher in the PSI group than in the CO group (P = 0.042, 0.040, and 0.034, respectively). Conclusion . For patients with medial compartment KOA, calibratable PSI can assist the surgeon in MOWHTO with superior accuracy and clinical efficacy. This study was conducted under Randomized Controlled Trial Details (RCT) with Registry Number ChiCTR2000038619 . … (more)
- Is Part Of:
- BioMed research international. Volume 2022(2022)
- Journal:
- BioMed research international
- Issue:
- Volume 2022(2022)
- Issue Display:
- Volume 2022, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 2022
- Issue:
- 2022
- Issue Sort Value:
- 2022-2022-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11-23
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2022/1378042 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 24642.xml