6‐year results of BiOSS stents in coronary bifurcation treatment. (29th March 2021)
- Record Type:
- Journal Article
- Title:
- 6‐year results of BiOSS stents in coronary bifurcation treatment. (29th March 2021)
- Main Title:
- 6‐year results of BiOSS stents in coronary bifurcation treatment
- Authors:
- Gil, Robert J.
Kern, Adam
Formuszewicz, Radoslaw
Iñigo Garcia, Luis A.
Dobrzycki, Slawomir
Vassilev, Dobrin
Bil, Jacek - Abstract:
- Abstract: Background: The wide variation in bifurcation anatomy has generated an ongoing search for stents explicitly designed for coronary bifurcations, and to date, results have been underachieved. Methods: The POLBOS I and POLBOS II were international, multicentre, randomized, open‐label, controlled trials. Patients were randomly assigned to BiOSS Expert (in POLBOS I, biodegradable polymer eluting paclitaxel)/BiOSS LIM (in POLBOS II, biodegradable polymer eluting sirolimus) stent implantation or regular drug‐eluting stent (rDES) deployment. A provisional T‐stenting strategy was the default treatment option. The primary endpoint of this pooled data study was the cumulative rate of major adverse cardiovascular events (MACE) consisting of cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR). Telephone follow‐up was performed annually up to 72 months. (ClinicalTrials.gov Identifier: POLBOS I—NCT02192840, POLBOS II—NCT02198300). Results: The total study population consisted of 445 patients, 222 patients in the BiOSS group and 223 patients in the rDES group. The follow‐up rate was 93.7% in the BiOSS group and 91.9% in the rDES group. At 72 months, there was no significant difference between BiOSS and rDES groups regarding MACE (25.7% vs 25.1%, HR 1.06, 95% CI 0.73‐1.52), cardiac death (3.1% vs 4.0%, HR 0.94, 95% CI 0.43‐2.34), MI (3.6% vs 4.9%, HR 0.76, 95% CI 0.32‐2.89), TLR (18.9% vs 16.1%, HR 1.17, 95% CI 0.75‐1.83) and stent thrombosis ratesAbstract: Background: The wide variation in bifurcation anatomy has generated an ongoing search for stents explicitly designed for coronary bifurcations, and to date, results have been underachieved. Methods: The POLBOS I and POLBOS II were international, multicentre, randomized, open‐label, controlled trials. Patients were randomly assigned to BiOSS Expert (in POLBOS I, biodegradable polymer eluting paclitaxel)/BiOSS LIM (in POLBOS II, biodegradable polymer eluting sirolimus) stent implantation or regular drug‐eluting stent (rDES) deployment. A provisional T‐stenting strategy was the default treatment option. The primary endpoint of this pooled data study was the cumulative rate of major adverse cardiovascular events (MACE) consisting of cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR). Telephone follow‐up was performed annually up to 72 months. (ClinicalTrials.gov Identifier: POLBOS I—NCT02192840, POLBOS II—NCT02198300). Results: The total study population consisted of 445 patients, 222 patients in the BiOSS group and 223 patients in the rDES group. The follow‐up rate was 93.7% in the BiOSS group and 91.9% in the rDES group. At 72 months, there was no significant difference between BiOSS and rDES groups regarding MACE (25.7% vs 25.1%, HR 1.06, 95% CI 0.73‐1.52), cardiac death (3.1% vs 4.0%, HR 0.94, 95% CI 0.43‐2.34), MI (3.6% vs 4.9%, HR 0.76, 95% CI 0.32‐2.89), TLR (18.9% vs 16.1%, HR 1.17, 95% CI 0.75‐1.83) and stent thrombosis rates (0.9% vs 0.5%, HR 1.21, 95CI 0.75‐2.09). Conclusions: At the 6‐year follow‐up, clinically significant clinical events did not differ between BiOSS stents and rDES. … (more)
- Is Part Of:
- European journal of clinical investigation. Volume 51:Number 8(2021)
- Journal:
- European journal of clinical investigation
- Issue:
- Volume 51:Number 8(2021)
- Issue Display:
- Volume 51, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 51
- Issue:
- 8
- Issue Sort Value:
- 2021-0051-0008-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-03-29
- Subjects:
- coronary bifurcation -- left main -- sirolimus‐eluting stent -- SYNTAX
Pathology -- Periodicals
Medical research -- Periodicals
616.075 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2362 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/eci.13555 ↗
- Languages:
- English
- ISSNs:
- 0014-2972
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.727100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24654.xml