Novel endoscopic ultrasonography imaging technique for visualizing microcirculation without contrast enhancement in subepithelial lesions: Prospective study. Issue 6 (23rd December 2020)
- Record Type:
- Journal Article
- Title:
- Novel endoscopic ultrasonography imaging technique for visualizing microcirculation without contrast enhancement in subepithelial lesions: Prospective study. Issue 6 (23rd December 2020)
- Main Title:
- Novel endoscopic ultrasonography imaging technique for visualizing microcirculation without contrast enhancement in subepithelial lesions: Prospective study
- Authors:
- Yamashita, Yasunobu
Yoshikawa, Takanori
Kawaji, Yuki
Tamura, Takashi
Hatamaru, Keiichi
Itonaga, Masahiro
Ida, Yoshiyuki
Maekita, Takao
Iguchi, Mikitaka
Murata, Shin?ichi
Kitano, Masayuki - Abstract:
- Abstract : Objectives: Detective flow imaging for endoscopic ultrasonography (DFI?EUS) is a new imaging modality developed for detecting fine vessels without using ultrasound contrast agents. This study aimed to evaluate its utility by comparing it with a type of directional power Doppler (eFLOW) for subepithelial lesions (SELs). Methods: Between January 2019 and January 2020, 28 patients with SELs undergoing DFI?EUS and eFLOW?EUS were enrolled. DFI?EUS and eFLOW?EUS assessing the vascularity in SELs were compared in terms of the rates of identification of intratumoral vessels. We also investigated how large vessels were depicted in both modalities based on surgical specimens as well as the detection rates of intratumoral vessels in gastrointestinal stromal tumors (GISTs) and non?GISTs using either DFI?EUS or eFLOW?EUS. Results: Among 28 patients, 23 with pathological confirmation by EUS?guided fine?needle aspiration biopsy (EUS?FNAB) specimens were included. Of those 23 patients, the 10 who underwent surgical resection were selected for analysis. The rate of detection of intratumoral vessels in SELs was significantly higher on DFI?EUS (80%) than on eFLOW?EUS (30%) ( P \xA0=\xA00.03). Comparison with surgical specimens revealed that detection rate for vessels with maximum size of less 1000\xA0μm was higher in DFI?EUS (66%) than that in eFLOW?EUS (0%). GIST patients had significantly higher positive rates (90%) of intratumoral vessels than non?GIST patients (31%) on DFI in 23Abstract : Objectives: Detective flow imaging for endoscopic ultrasonography (DFI?EUS) is a new imaging modality developed for detecting fine vessels without using ultrasound contrast agents. This study aimed to evaluate its utility by comparing it with a type of directional power Doppler (eFLOW) for subepithelial lesions (SELs). Methods: Between January 2019 and January 2020, 28 patients with SELs undergoing DFI?EUS and eFLOW?EUS were enrolled. DFI?EUS and eFLOW?EUS assessing the vascularity in SELs were compared in terms of the rates of identification of intratumoral vessels. We also investigated how large vessels were depicted in both modalities based on surgical specimens as well as the detection rates of intratumoral vessels in gastrointestinal stromal tumors (GISTs) and non?GISTs using either DFI?EUS or eFLOW?EUS. Results: Among 28 patients, 23 with pathological confirmation by EUS?guided fine?needle aspiration biopsy (EUS?FNAB) specimens were included. Of those 23 patients, the 10 who underwent surgical resection were selected for analysis. The rate of detection of intratumoral vessels in SELs was significantly higher on DFI?EUS (80%) than on eFLOW?EUS (30%) ( P \xA0=\xA00.03). Comparison with surgical specimens revealed that detection rate for vessels with maximum size of less 1000\xA0μm was higher in DFI?EUS (66%) than that in eFLOW?EUS (0%). GIST patients had significantly higher positive rates (90%) of intratumoral vessels than non?GIST patients (31%) on DFI in 23 cases including EUS?FNAB specimens ( P \xA0=\xA00.045). Conclusions: Detective flow imaging?EUS is more sensitive for depicting intratumoral vessels than eFLOW?EUS. Evaluation of intratumoral vessels on DFI?EUS is useful for identifying GISTs without contrast agents. … (more)
- Is Part Of:
- Digestive endoscopy. Volume 33:Issue 6(2021)
- Journal:
- Digestive endoscopy
- Issue:
- Volume 33:Issue 6(2021)
- Issue Display:
- Volume 33, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 6
- Issue Sort Value:
- 2021-0033-0006-0000
- Page Start:
- 955
- Page End:
- 961
- Publication Date:
- 2020-12-23
- Subjects:
- detective flow imaging endoscopic ultrasonography -- directional power Doppler endoscopic ultrasonography -- gastrointestinal stromal tumors -- subepithelial lesions
Digestive organs -- Diseases -- Periodicals
Digestive organs -- Diseases -- Diagnosis -- Periodicals
Endoscopy -- Periodicals
Digestive System Diseases -- diagnosis -- Periodicals
Digestive System Diseases -- therapy -- Periodicals
Endoscopy -- Periodicals
616.3 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/den.13889 ↗
- Languages:
- English
- ISSNs:
- 0915-5635
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3588.346200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24656.xml