Cross correlation–based misregistration correction for super resolution T2‐weighted spin‐echo images: application to prostate. Issue 3 (24th September 2020)
- Record Type:
- Journal Article
- Title:
- Cross correlation–based misregistration correction for super resolution T2‐weighted spin‐echo images: application to prostate. Issue 3 (24th September 2020)
- Main Title:
- Cross correlation–based misregistration correction for super resolution T2‐weighted spin‐echo images: application to prostate
- Authors:
- Borisch, Eric A.
Grimm, Roger C.
Kargar, Soudabeh
Kawashima, Akira
Rossman, Phillip J.
Riederer, Stephen J. - Abstract:
- Abstract : Purpose: The purpose is to develop a retrospective correction for subtle slice‐to‐slice positional inconsistencies that can occur when overlapped slices are acquired for super resolution in T2 ‐weighted spin‐echo multislice imaging. Methods: Spin‐echo acquisition of overlapped slices is typically done using multiple passes. After the passes are assembled into the final slice set, consecutive slices are correlated due to their overlap. Cross correlation was used to measure slice‐to‐slice displacement. After Z ‐dependent filtering to preserve true object shape, the displacements were used to correct slice position. The method was tested in a phantom moved slowly (0.16‐0.63 mm/pass) under computer control and in vivo in 16 patients having prostate MRI. Results: Over the motion range, the correlation method had an accuracy within 0.03 mm/pass and precision ± 0.20 mm (ie, subpixel). Corrected images visually resemble the true object. Over the patient studies, the mean range of motion in the anterior–posterior direction was 1.63 mm. Motion‐corrected axial images and the sagittal reformats were evaluated as significantly superior over those formed without motion correction. Conclusion: The retrospective correlation‐based motion‐correction method provides significant improvement in the slice‐to‐slice registration necessary for effective super resolution using overlapped slices.
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 3(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 3(2021)
- Issue Display:
- Volume 85, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 3
- Issue Sort Value:
- 2021-0085-0003-0000
- Page Start:
- 1350
- Page End:
- 1363
- Publication Date:
- 2020-09-24
- Subjects:
- misregistration artifact -- motion correction -- prostate MRI -- T2‐weighted spin echo -- through‐plane super resolution
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28518 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24636.xml