Clinical implications of elective replacement indicator setting changes in patients with dual‐chamber pacemaker devices. (24th July 2020)
- Record Type:
- Journal Article
- Title:
- Clinical implications of elective replacement indicator setting changes in patients with dual‐chamber pacemaker devices. (24th July 2020)
- Main Title:
- Clinical implications of elective replacement indicator setting changes in patients with dual‐chamber pacemaker devices
- Authors:
- Phillips, Kari A.
Ponamgi, Shiva
Mundell, Benjamin
Krushelnytskyy, Mykhaylo
Li, Zhuo
Rea, Robert
Deshmukh, Abhishek
McLeod, Christopher
Espinosa, Raul E.
Osborn, Michael
Friedman, Paul A.
Mulpuru, Siva K.
Cha, Yong‐Mei
Neutzling, Lori B.
Munger, Thomas
Kancharla, Krishna
Asirvatham, Samuel J. - Abstract:
- Abstract: Objective: This study sought to determine if single‐chamber operation and/or loss of rate response (RR) during elective replacement indicator (ERI) in patients with dual‐chamber pacemakers lead to increased symptom burden, healthcare utilization, and atrial fibrillation (AF). Background: Dual‐chamber pacemakers often change from dual‐ to single‐chamber pacing mode and/or lose RR functionality at ERI to preserve battery. Single‐chamber pacing increases the incidence of heart failure, AF, and pacemaker syndrome suggesting these changes may be deleterious. Methods: A retrospective analysis of 700 patients was completed. Three comparisons were analyzed: Comparison 1: mode change and RR loss versus no change; Comparison 2: RR loss only versus no change; Comparison 3: mode change only versus no change (in patients with no RR programmed at baseline). Results: In Comparison 1, 121 (46%) patients with setting changes experienced symptoms (most often dyspnea and fatigue/exercise intolerance) versus 3 (4%) without setting changes ( p < .0001). Similar results were noted in Comparisons 2 and 3 ( p = .0016 and p = .0001, respectively). In Comparison 1, patients with setting change sought provider contact more than patients without setting changes ( p = .0001). A significant difference was not noted in Comparison 2 or 3. Overall 14 (2%) patients were hospitalized, all of whom had setting changes. Conclusions: Setting changes at ERI including a change from dual‐ toAbstract: Objective: This study sought to determine if single‐chamber operation and/or loss of rate response (RR) during elective replacement indicator (ERI) in patients with dual‐chamber pacemakers lead to increased symptom burden, healthcare utilization, and atrial fibrillation (AF). Background: Dual‐chamber pacemakers often change from dual‐ to single‐chamber pacing mode and/or lose RR functionality at ERI to preserve battery. Single‐chamber pacing increases the incidence of heart failure, AF, and pacemaker syndrome suggesting these changes may be deleterious. Methods: A retrospective analysis of 700 patients was completed. Three comparisons were analyzed: Comparison 1: mode change and RR loss versus no change; Comparison 2: RR loss only versus no change; Comparison 3: mode change only versus no change (in patients with no RR programmed at baseline). Results: In Comparison 1, 121 (46%) patients with setting changes experienced symptoms (most often dyspnea and fatigue/exercise intolerance) versus 3 (4%) without setting changes ( p < .0001). Similar results were noted in Comparisons 2 and 3 ( p = .0016 and p = .0001, respectively). In Comparison 1, patients with setting change sought provider contact more than patients without setting changes ( p = .0001). A significant difference was not noted in Comparison 2 or 3. Overall 14 (2%) patients were hospitalized, all of whom had setting changes. Conclusions: Setting changes at ERI including a change from dual‐ to single‐chamber pacing and/or loss of RR results in a significantly increased symptom burden and increased healthcare utilization. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 31:Number 10(2020)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 31:Number 10(2020)
- Issue Display:
- Volume 31, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 10
- Issue Sort Value:
- 2020-0031-0010-0000
- Page Start:
- 2704
- Page End:
- 2710
- Publication Date:
- 2020-07-24
- Subjects:
- dual‐chamber pacemaker -- elective replacement indicator
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14677 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24635.xml