A geometric approach to separate the effects of magnetic susceptibility and chemical shift/exchange in a phantom with isotropic magnetic susceptibility. Issue 1 (8th July 2020)
- Record Type:
- Journal Article
- Title:
- A geometric approach to separate the effects of magnetic susceptibility and chemical shift/exchange in a phantom with isotropic magnetic susceptibility. Issue 1 (8th July 2020)
- Main Title:
- A geometric approach to separate the effects of magnetic susceptibility and chemical shift/exchange in a phantom with isotropic magnetic susceptibility
- Authors:
- Eun, Hyunsung
Jeong, Hwihun
Lee, Jingu
Shin, Hyeong‐Geol
Lee, Jongho - Abstract:
- Abstract : Purpose: To separate the effects of magnetic susceptibility and chemical shift/exchange in a phantom with isotropic magnetic susceptibility, and to generate a chemical shift/exchange‐corrected QSM result. Methods: Magnetic susceptibility and chemical shift/exchange are the properties of a material. Both are known to induce the resonance frequency shift in MRI. In current QSM, the susceptibility is reconstructed from the frequency shift, ignoring the contribution of the chemical shift/exchange. In this work, a simple geometric approach, which averages the frequency shift maps from three orthogonal B0 directions to generate a chemical shift/exchange map, is developed using the fact that the average nullifies the (isotropic) susceptibility effects. The resulting chemical shift/exchange map is subtracted from the total frequency shift, producing a frequency shift map solely from susceptibility. Finally, this frequency shift map is reconstructed to a susceptibility map using a QSM algorithm. The proposed method is validated in numerical simulations and applied to phantom experiments with olive oil, bovine serum albumin, ferritin, and iron oxide solutions. Results: Both simulations and experiments confirm that the method successfully separates the contributions of the susceptibility and chemical shift/exchange, reporting the susceptibility and chemical shift/exchange of olive oil (susceptibility: 0.62 ppm, chemical shift: −3.60 ppm), bovine serum albuminAbstract : Purpose: To separate the effects of magnetic susceptibility and chemical shift/exchange in a phantom with isotropic magnetic susceptibility, and to generate a chemical shift/exchange‐corrected QSM result. Methods: Magnetic susceptibility and chemical shift/exchange are the properties of a material. Both are known to induce the resonance frequency shift in MRI. In current QSM, the susceptibility is reconstructed from the frequency shift, ignoring the contribution of the chemical shift/exchange. In this work, a simple geometric approach, which averages the frequency shift maps from three orthogonal B0 directions to generate a chemical shift/exchange map, is developed using the fact that the average nullifies the (isotropic) susceptibility effects. The resulting chemical shift/exchange map is subtracted from the total frequency shift, producing a frequency shift map solely from susceptibility. Finally, this frequency shift map is reconstructed to a susceptibility map using a QSM algorithm. The proposed method is validated in numerical simulations and applied to phantom experiments with olive oil, bovine serum albumin, ferritin, and iron oxide solutions. Results: Both simulations and experiments confirm that the method successfully separates the contributions of the susceptibility and chemical shift/exchange, reporting the susceptibility and chemical shift/exchange of olive oil (susceptibility: 0.62 ppm, chemical shift: −3.60 ppm), bovine serum albumin (susceptibility: −0.059 ppm, chemical shift: 0.008 ppm), ferritin (susceptibility: 0.125 ppm, chemical shift: −0.005 ppm), and iron oxide (susceptibility: 0.30 ppm, chemical shift: −0.039 ppm) solutions. Conclusion: The proposed method successfully separates the susceptibility and chemical shift/exchange in phantoms with isotropic magnetic susceptibility. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 1(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 1(2021)
- Issue Display:
- Volume 85, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 1
- Issue Sort Value:
- 2021-0085-0001-0000
- Page Start:
- 281
- Page End:
- 289
- Publication Date:
- 2020-07-08
- Subjects:
- chemical exchange -- chemical shift -- magnetic susceptibility -- quantitative MR -- quantitative susceptibility mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28408 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24631.xml