Accelerating in vivo fast spin echo high angular resolution diffusion imaging with an isotropic resolution in mice through compressed sensing. Issue 3 (3rd October 2020)
- Record Type:
- Journal Article
- Title:
- Accelerating in vivo fast spin echo high angular resolution diffusion imaging with an isotropic resolution in mice through compressed sensing. Issue 3 (3rd October 2020)
- Main Title:
- Accelerating in vivo fast spin echo high angular resolution diffusion imaging with an isotropic resolution in mice through compressed sensing
- Authors:
- Naeyaert, Maarten
Aelterman, Jan
Van Audekerke, Johan
Golkov, Vladimir
Cremers, Daniel
Pižurica, Aleksandra
Sijbers, Jan
Verhoye, Marleen - Abstract:
- Abstract : Purpose: Echo planar imaging (EPI) is commonly used to acquire the many volumes needed for high angular resolution diffusion Imaging (HARDI), posing a higher risk for artifacts, such as distortion and deformation. An alternative to EPI is fast spin echo (FSE) imaging, which has fewer artifacts but is inherently slower. The aim is to accelerate FSE such that a HARDI data set can be acquired in a time comparable to EPI using compressed sensing. Methods: Compressed sensing was applied in either q‐space or simultaneously in k‐space and q‐space, by undersampling the k‐space in the phase‐encoding direction or retrospectively eliminating diffusion directions for different degrees of undersampling. To test the replicability of the acquisition and reconstruction, brain data were acquired from six mice, and a numerical phantom experiment was performed. All HARDI data were analyzed individually using constrained spherical deconvolution, and the apparent fiber density and complexity metric were evaluated, together with whole‐brain tractography. Results: The apparent fiber density and complexity metric showed relatively minor differences when only q‐space undersampling was used, but deteriorate when k‐space undersampling was applied. Likewise, the tract density weighted image showed good results when only q‐space undersampling was applied using 15 directions or more, but information was lost when fewer volumes or k‐space undersampling were used. Conclusion: It was found thatAbstract : Purpose: Echo planar imaging (EPI) is commonly used to acquire the many volumes needed for high angular resolution diffusion Imaging (HARDI), posing a higher risk for artifacts, such as distortion and deformation. An alternative to EPI is fast spin echo (FSE) imaging, which has fewer artifacts but is inherently slower. The aim is to accelerate FSE such that a HARDI data set can be acquired in a time comparable to EPI using compressed sensing. Methods: Compressed sensing was applied in either q‐space or simultaneously in k‐space and q‐space, by undersampling the k‐space in the phase‐encoding direction or retrospectively eliminating diffusion directions for different degrees of undersampling. To test the replicability of the acquisition and reconstruction, brain data were acquired from six mice, and a numerical phantom experiment was performed. All HARDI data were analyzed individually using constrained spherical deconvolution, and the apparent fiber density and complexity metric were evaluated, together with whole‐brain tractography. Results: The apparent fiber density and complexity metric showed relatively minor differences when only q‐space undersampling was used, but deteriorate when k‐space undersampling was applied. Likewise, the tract density weighted image showed good results when only q‐space undersampling was applied using 15 directions or more, but information was lost when fewer volumes or k‐space undersampling were used. Conclusion: It was found that acquiring 15 to 20 diffusion directions with a full k‐space and reconstructed using compressed sensing could suffice for a replicable measurement of quantitative measures in mice, where areas near the sinuses and ear cavities are untainted by signal loss. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 3(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 3(2021)
- Issue Display:
- Volume 85, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 3
- Issue Sort Value:
- 2021-0085-0003-0000
- Page Start:
- 1397
- Page End:
- 1413
- Publication Date:
- 2020-10-03
- Subjects:
- compressed sensing -- diffusion -- fast spin echo -- HARDI -- turbo spin echo
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28520 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24636.xml