Prospective evaluation of thoracic diseases using a compact flat-panel detector spiral computed tomographic scanner. (2022)
- Record Type:
- Journal Article
- Title:
- Prospective evaluation of thoracic diseases using a compact flat-panel detector spiral computed tomographic scanner. (2022)
- Main Title:
- Prospective evaluation of thoracic diseases using a compact flat-panel detector spiral computed tomographic scanner
- Authors:
- Kim, Da Som
Yoo, Seung-Jin
Hong, Jung Hee
Kwak, Nakwon
Yim, Jae-Joon
Yoon, Soon Ho - Abstract:
- Abstract: Objective: To prospectively evaluate the image quality and diagnostic performance of a compact flat-panel detector (FD) scanner for thoracic diseases compared to a clinical CT scanner. Materials and methods: The institutional review board approved this single-center prospective study, and all participants provided informed consent. From December 2020 to May 2021, 30 patients (mean age, 67.1 ± 8.3 years) underwent two same-day low-dose chest CT scans using clinical state-of-art and compact FDCT scanners. Image quality was assessed visually and quantitatively. Two readers evaluated the diagnostic performance for nodules, parenchymal opacifications, bronchiectasis, linear opacities, and pleural abnormalities in 40 paired CT scans. The other 20 paired CT scans were used to examine the agreement of semi-quantitative CT scoring regarding bronchiectasis, bronchiolitis, nodules, airspace consolidations, and cavities. Results: FDCT images had significantly lower visual image quality than clinical CT images (all p < 0.001). The two CT image sets showed no significant differences in signal-to-noise and contrast-to-noise ratios (56.8 ± 12.5 vs. 57.3 ± 15.2; p = 0.985 and 62.9 ± 11.7 vs. 60.7 ± 16.9; p = 0.615). The pooled sensitivity was comparable for nodules, parenchymal opacifications, linear opacities, and pleural abnormalities ( p = 0.065–0.625), whereas the sensitivity was significantly lower in FDCT images than in clinical CT images for micronodules ( p = 0.007)Abstract: Objective: To prospectively evaluate the image quality and diagnostic performance of a compact flat-panel detector (FD) scanner for thoracic diseases compared to a clinical CT scanner. Materials and methods: The institutional review board approved this single-center prospective study, and all participants provided informed consent. From December 2020 to May 2021, 30 patients (mean age, 67.1 ± 8.3 years) underwent two same-day low-dose chest CT scans using clinical state-of-art and compact FDCT scanners. Image quality was assessed visually and quantitatively. Two readers evaluated the diagnostic performance for nodules, parenchymal opacifications, bronchiectasis, linear opacities, and pleural abnormalities in 40 paired CT scans. The other 20 paired CT scans were used to examine the agreement of semi-quantitative CT scoring regarding bronchiectasis, bronchiolitis, nodules, airspace consolidations, and cavities. Results: FDCT images had significantly lower visual image quality than clinical CT images (all p < 0.001). The two CT image sets showed no significant differences in signal-to-noise and contrast-to-noise ratios (56.8 ± 12.5 vs. 57.3 ± 15.2; p = 0.985 and 62.9 ± 11.7 vs. 60.7 ± 16.9; p = 0.615). The pooled sensitivity was comparable for nodules, parenchymal opacifications, linear opacities, and pleural abnormalities ( p = 0.065–0.625), whereas the sensitivity was significantly lower in FDCT images than in clinical CT images for micronodules ( p = 0.007) and bronchiectasis ( p = 0.004). The specificity was mostly 1.0. Semi-quantitative CT scores were similar between the CT image sets ( p > 0.05), and intraclass correlation coefficients were around 0.950 or higher, except for bronchiectasis (0.869). Conclusion: Compact FDCT images provided lower image quality but comparable diagnostic performance to clinical CT images for nodules, parenchymal opacifications, linear opacities, and pleural abnormalities. … (more)
- Is Part Of:
- European journal of radiology open. Volume 9(2022)
- Journal:
- European journal of radiology open
- Issue:
- Volume 9(2022)
- Issue Display:
- Volume 9, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 9
- Issue:
- 2022
- Issue Sort Value:
- 2022-0009-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022
- Subjects:
- Computed tomography -- Flat panel detector -- Thoracic disease -- Diagnosis
CT computed tomography -- COVID-19 coronavirus disease 2019 -- LDCT low-dose CT -- FD flat-panel detector -- SNR signal-to-noise ratio -- CNR contrast-to-noise ratio -- ROI region of interest -- POC point-of-care -- NTM nontuberculous mycobacterial -- ICC intraclass correlation coefficient
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2022.100452 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24636.xml