Third‐generation continuous‐flow left ventricular assist devices: a comparative outcome analysis by device type. (26th July 2022)
- Record Type:
- Journal Article
- Title:
- Third‐generation continuous‐flow left ventricular assist devices: a comparative outcome analysis by device type. (26th July 2022)
- Main Title:
- Third‐generation continuous‐flow left ventricular assist devices: a comparative outcome analysis by device type
- Authors:
- Mihalj, Maks
Heinisch, Paul Philipp
Schober, Patrick
Wieser, Monika
Martinelli, Michele
de By, Theo M.M.H.
Schefold, Joerg C.
Luedi, Markus M.
Kadner, Alexander
Carrel, Thierry
Mohacsi, Paul
Hunziker, Lukas
Reineke, David - Abstract:
- Abstract: Aims: Continuous‐flow left ventricular assist devices (CF‐LVADs) have become a standard of care in end‐stage heart failure. Limited data exist comparing outcomes of HeartMate3 (HM3) and HeartWare HVAD (HW). We aimed to compare midterm outcomes of these devices. Methods and results: Investigator‐initiated retrospective‐observational comparative analysis of all patients who underwent primary LVAD implantation of either HM3 or HW at our centre between January 2010 and December 2020. Data were derived from a prospective registry. Primary endpoints were all‐cause mortality and heart transplantation. Secondary endpoints included device‐related major adverse cardiac and cerebrovascular events, which included major bleeding, major neurological dysfunction (defined as persisting neurological impairment for ≥24 h), device‐related major infection (excluding driveline infections), major device malfunctions leading to re‐intervention or partial device exchange (pump failure, outflow‐graft twist or failure, controller failure, battery failure, patient cable failure, but excluding pump thrombosis), and pump thrombosis. Further secondary endpoints included right heart failure, gastrointestinal bleeding, driveline infections, and surgical re‐interventions. The secondary outcomes were analysed not only for the first event but also for recurrent events. The analysis included competing risks analysis and recurrent event regression analysis, with adjustment for confounders age, gender,Abstract: Aims: Continuous‐flow left ventricular assist devices (CF‐LVADs) have become a standard of care in end‐stage heart failure. Limited data exist comparing outcomes of HeartMate3 (HM3) and HeartWare HVAD (HW). We aimed to compare midterm outcomes of these devices. Methods and results: Investigator‐initiated retrospective‐observational comparative analysis of all patients who underwent primary LVAD implantation of either HM3 or HW at our centre between January 2010 and December 2020. Data were derived from a prospective registry. Primary endpoints were all‐cause mortality and heart transplantation. Secondary endpoints included device‐related major adverse cardiac and cerebrovascular events, which included major bleeding, major neurological dysfunction (defined as persisting neurological impairment for ≥24 h), device‐related major infection (excluding driveline infections), major device malfunctions leading to re‐intervention or partial device exchange (pump failure, outflow‐graft twist or failure, controller failure, battery failure, patient cable failure, but excluding pump thrombosis), and pump thrombosis. Further secondary endpoints included right heart failure, gastrointestinal bleeding, driveline infections, and surgical re‐interventions. The secondary outcomes were analysed not only for the first event but also for recurrent events. The analysis included competing risks analysis and recurrent event regression analysis, with adjustment for confounders age, gender, body mass index (BMI), and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level. Out of 106 primary CF‐LVAD implantations, 36 (34%) received HM3 and 70 (66%) received HW. Median follow‐up was 1.48 years [interquartile range 0.67, 2.41]. HM3 was more often implanted in men (91.7% vs. 72.9%, P = 0.024); patients were older (median 61 years [54, 66.5] vs. 52.5 years [43, 60], P < 0.001), had a higher BMI (median 26.7 kg/m 2 [23.4, 29.0] vs. 24.3 kg/m 2 [20.7, 27.4], P = 0.013), had more comorbidities, and were more likely targeted for destination therapy (36.1% vs. 14.3%, P = 0.010). Death occurred in 33.3% of HM3 patients, compared with 22.9% of HW patients, P = 0.247 (probability of survival at 4 years, 54.7% vs. 74.1%, P = 0.296). After adjustment for confounders, we observed a significant six‐fold risk increase in device malfunctions for HW [hazard ratio (HR) 6.49, 95% confidence interval (CI) [1.89, 22.32], P = 0.003], but no significant differences in pump thrombosis ( P = 0.173) or overall survival ( P = 0.801). Conclusions: Comparing midterm outcomes between HM3 and HW for LVAD support from a prospective registry, HW patients had a significantly higher risk of device malfunctions. No significant differences were evident between devices in overall survival and in respect to most outcomes. … (more)
- Is Part Of:
- ESC heart failure. Volume 9:Number 5(2022)
- Journal:
- ESC heart failure
- Issue:
- Volume 9:Number 5(2022)
- Issue Display:
- Volume 9, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 9
- Issue:
- 5
- Issue Sort Value:
- 2022-0009-0005-0000
- Page Start:
- 3469
- Page End:
- 3482
- Publication Date:
- 2022-07-26
- Subjects:
- Left ventricular assist device -- LVAD -- HeartMate3 -- HeartWare HVAD -- Outcome comparison
Heart failure -- Periodicals
616.129005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2055-5822 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ehf2.13794 ↗
- Languages:
- English
- ISSNs:
- 2055-5822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24617.xml