Cascaded high-density multipoint gas detection with branched gas chambers. (December 2022)
- Record Type:
- Journal Article
- Title:
- Cascaded high-density multipoint gas detection with branched gas chambers. (December 2022)
- Main Title:
- Cascaded high-density multipoint gas detection with branched gas chambers
- Authors:
- Yang, Jiahua
Lin, Huixian
He, Aohua
Dong, Xiaopeng - Abstract:
- Highlights: An optical fiber high-density multi-point gas detection technology for monitoring flammable and explosive gases across long distances and expansive regions that is safe and suited to severe conditions is described. On the basis of time-division multiplexing (TDM) technology, we offer the novel cascading branch gas chambers approach, which enables the separation of numerous gas sensor signals without crosstalk. We generate a gas-information-carrying reflection signal that is 1–2 orders of magnitude greater than the previously reported Rayleigh scattering scheme. Consequently, the system's dynamic range is greatly expanded, which may result in a substantial increase in the number of detection points. The delay line of the branch may be placed in any location to facilitate laying, and the price of a single sensor has been dramatically reduced, allowing engineering applications. The study should appeal to readers interested in distributed, multi-point gas monitoring, pipeline leakage monitoring, coal mine gas monitoring, and urban air quality monitoring. Abstract: Distributed or multipoint gas detection is crucial for several industrial and civil applications. Due to various losses, the traditional series–parallel method has a restricted number of measurement points. In this paper, an innovative cascaded connection method has been introduced for measuring a large number of locations. It is basically a branching route that contains a gas cell and a reflecting mirror.Highlights: An optical fiber high-density multi-point gas detection technology for monitoring flammable and explosive gases across long distances and expansive regions that is safe and suited to severe conditions is described. On the basis of time-division multiplexing (TDM) technology, we offer the novel cascading branch gas chambers approach, which enables the separation of numerous gas sensor signals without crosstalk. We generate a gas-information-carrying reflection signal that is 1–2 orders of magnitude greater than the previously reported Rayleigh scattering scheme. Consequently, the system's dynamic range is greatly expanded, which may result in a substantial increase in the number of detection points. The delay line of the branch may be placed in any location to facilitate laying, and the price of a single sensor has been dramatically reduced, allowing engineering applications. The study should appeal to readers interested in distributed, multi-point gas monitoring, pipeline leakage monitoring, coal mine gas monitoring, and urban air quality monitoring. Abstract: Distributed or multipoint gas detection is crucial for several industrial and civil applications. Due to various losses, the traditional series–parallel method has a restricted number of measurement points. In this paper, an innovative cascaded connection method has been introduced for measuring a large number of locations. It is basically a branching route that contains a gas cell and a reflecting mirror. A small amount of light is coupled to the branch channel, leading to limited effects on transmission power. Using a light source that corresponds to the gas absorption line, an optical time domain reflectometer (OTDR) device interrogates each cell by branching. After establishing a length of delay fiber at one of the branch locations, the signals coming from each air cell are recognized individually at the receiving end. In this experiment, 99:1 couplers are used, and only 1% of the total light is transferred to the branch route gas cell. The signal-to-noise ratio increases dramatically compared to previous studies based on Rayleigh scattering. This is because the amplitude of the reflected light is one-half order more than that of the scattered light. A 1530 nm laser for acetylene and a 1653 nm laser for methane with a short pulse width are used for evaluating the novel multipoint gas detection technique. There is an analysis and discussion of the number of measurement points. The proposed method is capable of optimally laying 220 cells at a maximum monitoring distance of 8.8 km within a dynamic range of ∼13.56 dB. Using the present wavelength power calibration method, the minimum detection limits for methane and acetylene along the 1% branching path are 0.093 low explosion level (LEL) and 0.321 LEL, respectively. … (more)
- Is Part Of:
- Measurement. Volume 205(2023)
- Journal:
- Measurement
- Issue:
- Volume 205(2023)
- Issue Display:
- Volume 205, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 205
- Issue:
- 2023
- Issue Sort Value:
- 2023-0205-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Multipoint gas detection -- Cascaded gas detection -- OTDR -- Distributed gas detection
Weights and measures -- Periodicals
Measurement -- Periodicals
Measurement
Weights and measures
Periodicals
530.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02632241 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.measurement.2022.112233 ↗
- Languages:
- English
- ISSNs:
- 0263-2241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5413.544700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24609.xml