Improving Accuracy and Confidence in Distal Radius Volar Plate Screw Placement through Supplemental Radiography: Examining Specialty, Education, and Experience Levels. (September 2013)
- Record Type:
- Journal Article
- Title:
- Improving Accuracy and Confidence in Distal Radius Volar Plate Screw Placement through Supplemental Radiography: Examining Specialty, Education, and Experience Levels. (September 2013)
- Main Title:
- Improving Accuracy and Confidence in Distal Radius Volar Plate Screw Placement through Supplemental Radiography: Examining Specialty, Education, and Experience Levels
- Authors:
- Patel, Archit
Culbertson, Maya Deza
Lahey, Philip
Semenovski, Michael
Choueka, Jack - Abstract:
- Background: The purpose of this study was to assess the extent to which a supplemental radiographic view increases accuracy and confidence ratings when determining screw placement in volar plating of distal radius fractures for evaluators of different specialties and experience levels. Methods: Thirty-four distal radius fractures treated with volar plate fixation were imaged using standard AP and lateral, and supplemental lateral tilt views. Each case was then evaluated for penetration of distal screw tips into the articular space. Sixty-five physicians then completed a two-phase analysis and survey of these cases. In the first phase, presentation consisted only of AP and lateral views; in the second, the lateral tilt view was added. Participants were asked to determine whether distal screws penetrated the joint and rate their confidence in the determination. Assessments were scored for correctness; changes in accuracy and confidence levels between phases were analyzed using paired t tests. Comparisons between groups were performed by ANOVA. Results: Supplementation increased accuracy and confidence in all position, specialty, and experience groups. Confidence scores were significantly higher following evaluation of three views versus two views. Residents exhibited the greatest improvements in accuracy and confidence. For first-phase (standard view) assessments, accuracy scores were significantly better for attendings with less than 10 years post-fellowship experience thanBackground: The purpose of this study was to assess the extent to which a supplemental radiographic view increases accuracy and confidence ratings when determining screw placement in volar plating of distal radius fractures for evaluators of different specialties and experience levels. Methods: Thirty-four distal radius fractures treated with volar plate fixation were imaged using standard AP and lateral, and supplemental lateral tilt views. Each case was then evaluated for penetration of distal screw tips into the articular space. Sixty-five physicians then completed a two-phase analysis and survey of these cases. In the first phase, presentation consisted only of AP and lateral views; in the second, the lateral tilt view was added. Participants were asked to determine whether distal screws penetrated the joint and rate their confidence in the determination. Assessments were scored for correctness; changes in accuracy and confidence levels between phases were analyzed using paired t tests. Comparisons between groups were performed by ANOVA. Results: Supplementation increased accuracy and confidence in all position, specialty, and experience groups. Confidence scores were significantly higher following evaluation of three views versus two views. Residents exhibited the greatest improvements in accuracy and confidence. For first-phase (standard view) assessments, accuracy scores were significantly better for attendings with less than 10 years post-fellowship experience than those with more. Conclusions: A supplemental view of the distal radius combined with AP and lateral views significantly improves the ability of all evaluators, regardless of specialty or training level, to correctly assess placement of fixation screws. The greatest improvements are seen for resident trainees. … (more)
- Is Part Of:
- Hand. Volume 8:Number 3(2013)
- Journal:
- Hand
- Issue:
- Volume 8:Number 3(2013)
- Issue Display:
- Volume 8, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 8
- Issue:
- 3
- Issue Sort Value:
- 2013-0008-0003-0000
- Page Start:
- 308
- Page End:
- 314
- Publication Date:
- 2013-09
- Subjects:
- Distal radius fracture -- Volar plate -- Fixation screw -- Arthrodesis -- Intra-articular -- Tilt radiography -- Fluoroscopy -- Hardware placement -- Postoperative evaluation -- DVR plate
Hand -- Surgery -- Periodicals
Hand -- Surgery
Periodicals
617.57005 - Journal URLs:
- http://www.springerlink.com/content/119980/ ↗
http://journals.sagepub.com/toc/HAN/current ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s11552-013-9528-3 ↗
- Languages:
- English
- ISSNs:
- 1558-9447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4241.550050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24568.xml