Evaluation of differences and dosimetric influences of beam models using golden and multi‐institutional measured beam datasets in radiation treatment planning systems. Issue 11 (15th October 2020)
- Record Type:
- Journal Article
- Title:
- Evaluation of differences and dosimetric influences of beam models using golden and multi‐institutional measured beam datasets in radiation treatment planning systems. Issue 11 (15th October 2020)
- Main Title:
- Evaluation of differences and dosimetric influences of beam models using golden and multi‐institutional measured beam datasets in radiation treatment planning systems
- Authors:
- Tani, Kensuke
Wakita, Akihisa
Tohyama, Naoki
Fujita, Yukio
Kito, Satoshi
Miyasaka, Ryohei
Mizuno, Norifumi
Uehara, Ryuzo
Takakura, Toru
Miyake, Shunsuke
Shinoda, Kazuya
Oka, Yoshitaka
Saito, Yasunori
Kojima, Hideki
Hayashi, Naoki - Abstract:
- Abstract : Purpose: The beam model in radiation treatment planning systems (RTPSs) plays a crucial role in determining the accuracy of calculated dose distributions. The purpose of this study was to ascertain differences in beam models and their dosimetric influences when a golden beam dataset (GBD) and multi‐institution measured beam datasets (MBDs) are used for beam modeling in RTPSs. Methods: The MBDs collected from 15 institutions, and the MBDs' beam models, were compared with a GBD, and the GBD's beam model, for Varian TrueBeam linear accelerator. The calculated dose distributions of the MBDs' beam models were compared with those of the GBD's beam model for simple geometries in a water phantom. Calculated dose distributions were similarly evaluated in volumetric modulated arc therapy (VMAT) plans for TG‐119 C‐shape and TG‐244 head and neck, at several dose constraints of the planning target volumes (PTVs), and organs at risk. Results: The agreements of the MBDs with the GBD were almost all within ±1%. The calculated dose distributions for simple geometries in a water phantom also closely corresponded between the beam models of GBD and MBDs. Nevertheless, there were considerable differences between the beam models. The maximum differences between the mean energy of the energy spectra of GBD and MBDs were −0.12 MeV (−10.5%) in AcurosXB (AXB, Eclipse) and 0.11 MeV (7.7%) in collapsed cone convolution (CCC, RayStation). The differences in the VMAT calculated doseAbstract : Purpose: The beam model in radiation treatment planning systems (RTPSs) plays a crucial role in determining the accuracy of calculated dose distributions. The purpose of this study was to ascertain differences in beam models and their dosimetric influences when a golden beam dataset (GBD) and multi‐institution measured beam datasets (MBDs) are used for beam modeling in RTPSs. Methods: The MBDs collected from 15 institutions, and the MBDs' beam models, were compared with a GBD, and the GBD's beam model, for Varian TrueBeam linear accelerator. The calculated dose distributions of the MBDs' beam models were compared with those of the GBD's beam model for simple geometries in a water phantom. Calculated dose distributions were similarly evaluated in volumetric modulated arc therapy (VMAT) plans for TG‐119 C‐shape and TG‐244 head and neck, at several dose constraints of the planning target volumes (PTVs), and organs at risk. Results: The agreements of the MBDs with the GBD were almost all within ±1%. The calculated dose distributions for simple geometries in a water phantom also closely corresponded between the beam models of GBD and MBDs. Nevertheless, there were considerable differences between the beam models. The maximum differences between the mean energy of the energy spectra of GBD and MBDs were −0.12 MeV (−10.5%) in AcurosXB (AXB, Eclipse) and 0.11 MeV (7.7%) in collapsed cone convolution (CCC, RayStation). The differences in the VMAT calculated dose distributions varied for each dose region, plan, X‐ray energy, and dose calculation algorithm. The ranges of the differences in the dose constraints were −5.6% to 3.0% for AXB and −24.1% to 2.8% for CCC. In several VMAT plans, the calculated dose distributions of GBD's beam model tended to be lower in high‐dose regions and higher in low‐dose regions than those of the MBDs' beam models. Conclusions: We found that small differences in beam data have large impacts on the beam models, and on calculated dose distributions in clinical VMAT plan, even if beam data correspond within ±1%. GBD's beam model was not a representative beam model. The beam models of GBD and MBDs and their calculated dose distributions under clinical conditions were significantly different. These differences are most likely due to the extensive variation in the beam models, reflecting the characteristics of beam data. The energy spectrum and radial energy in the beam model varied in a wide range, even if the differences in the beam data were <±1%. To minimize the uncertainty of the calculated dose distributions in clinical plans, it was best to use the institutional MBD for beam modeling, or the beam model that ensures the accuracy of calculated dose distributions. Abstract : … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 11(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 11(2020)
- Issue Display:
- Volume 47, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 11
- Issue Sort Value:
- 2020-0047-0011-0000
- Page Start:
- 5852
- Page End:
- 5871
- Publication Date:
- 2020-10-15
- Subjects:
- beam model -- golden beam data -- RTPS
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14493 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24564.xml