Performance assessment of sewage treatment plants using compliance index. (4th June 2022)
- Record Type:
- Journal Article
- Title:
- Performance assessment of sewage treatment plants using compliance index. (4th June 2022)
- Main Title:
- Performance assessment of sewage treatment plants using compliance index
- Authors:
- Ramkumar, D.
Jothiprakash, V.
Patil, B. N. - Abstract:
- Abstract: The aim of this study is to infer the performance assessment of sewage treatment plants (STPs) using the compliance index (CI). The methodology includes three steps, (1) estimation of performance indicators from the quality test, parameter test, and conformity test, (2) hypothesis testing of non-conformity, and (3) hypothesis testing using the non-parametric test. The CI integrates the results of the above nine tests through a scoring system based on individual performance. The study area, Navi Mumbai Municipal Corporation (NMMC), India, treats its domestic sewage through seven centralized STPs located in different zones. The influent and effluent parameters, such as flow rate, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), pH, dissolved oxygen (DO), and temperature, were studied in this work. The removal efficiency (RE) analysis shows the efficiency of BOD, COD, and TSS varies between 96.67 and 97.30%, 84.55 and 89.70%, and 94.04 and 95.81%, respectively, and indicates that all STPs are performing well. The proposed CI infers that all STPs perform well and comply with NMMC standards, except one STP, namely Airoli. Interestingly, RE analysis shows that Airoli STP's BOD is the third-best compared to all other STPs. This study shows that the CI method can infer the performance of STPs better than RE and help the administrators to plan, execute, operate, and maintain STPs to achieve total sanitation in megacities.Abstract: The aim of this study is to infer the performance assessment of sewage treatment plants (STPs) using the compliance index (CI). The methodology includes three steps, (1) estimation of performance indicators from the quality test, parameter test, and conformity test, (2) hypothesis testing of non-conformity, and (3) hypothesis testing using the non-parametric test. The CI integrates the results of the above nine tests through a scoring system based on individual performance. The study area, Navi Mumbai Municipal Corporation (NMMC), India, treats its domestic sewage through seven centralized STPs located in different zones. The influent and effluent parameters, such as flow rate, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), pH, dissolved oxygen (DO), and temperature, were studied in this work. The removal efficiency (RE) analysis shows the efficiency of BOD, COD, and TSS varies between 96.67 and 97.30%, 84.55 and 89.70%, and 94.04 and 95.81%, respectively, and indicates that all STPs are performing well. The proposed CI infers that all STPs perform well and comply with NMMC standards, except one STP, namely Airoli. Interestingly, RE analysis shows that Airoli STP's BOD is the third-best compared to all other STPs. This study shows that the CI method can infer the performance of STPs better than RE and help the administrators to plan, execute, operate, and maintain STPs to achieve total sanitation in megacities. HIGHLIGHTS: Proposed compliance index (CI) computes the performance of sewage treatment plants (STPs). The CI is constructed using influent and effluent wastewater quality parameters. The methodology was tested with seven STPs in one of India's cleanest cities. The advantage of the CI is that it handles non-stationary datasets. Proposed CI reveals much better compliance of STPs than the conventional removal efficiency analysis. Graphical Abstract … (more)
- Is Part Of:
- Journal of water, sanitation, and hygiene for development. Volume 12:Number 6(2022)
- Journal:
- Journal of water, sanitation, and hygiene for development
- Issue:
- Volume 12:Number 6(2022)
- Issue Display:
- Volume 12, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 12
- Issue:
- 6
- Issue Sort Value:
- 2022-0012-0006-0000
- Page Start:
- 485
- Page End:
- 497
- Publication Date:
- 2022-06-04
- Subjects:
- compliance index -- NMMC -- non-parametric -- removal efficiency -- STPs -- wastewater
Drinking water -- Sanitation -- Periodicals
Water-supply -- Periodicals
Drinking Water
Hygiene
Health Planning
Water-supply
Health planning
Hygiene
Drinking water -- Quality
Sanitation
Electronic journals
Periodicals
Periodicals
363.6105 - Journal URLs:
- https://iwaponline.com/washdev ↗
https://iwaponline.com/washdev/issue/browse-by-year ↗
http://www.iwaponline.com/washdev/toc.htm ↗ - DOI:
- 10.2166/washdev.2022.055 ↗
- Languages:
- English
- ISSNs:
- 2043-9083
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 24563.xml